Deep Learning–Based Detection of Intracranial Aneurysms in 3D TOF-MRA
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: The rupture of an intracranial aneurysm is a serious incident, causing subarachnoid hemorrhage associated with high fatality and morbidity rates. Because the demand for radiologic examinations is steadily growing, physician fatigue due to an increased workload is a real concern and may lead to mistaken diagnoses of potentially relevant findings. Our aim was to develop a sufficient system for automated detection of intracranial aneurysms. MATERIALS AND METHODS: In a retrospective study, we established a system for the detection of intracranial aneurysms from 3D TOF-MRA data. The system is based on an open-source neural network, originally developed for segmentation of anatomic structures in medical images. Eighty-five datasets of patients with a total of 115 intracranial aneurysms were used to train the system and evaluate its performance. Manual annotation of aneurysms based on radiologic reports and critical revision of image data served as the reference standard. Sensitivity, false-positives per case, and positive predictive value were determined for different pipelines with modified pre- and postprocessing. RESULTS: The highest overall sensitivity of our system for the detection of intracranial aneurysms was 90% with a sensitivity of 96% for aneurysms with a diameter of 3-7 mm and 100% for aneurysms of >7 mm. The best location-dependent performance was in the posterior circulation. Pre- and postprocessing sufficiently reduced the number of false-positives. CONCLUSIONS: Our system, based on a deep learning convolutional network, can detect intracranial aneurysms with a high sensitivity from 3D TOF-MRA data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332 · cited 2×
“13 14-17 However, a deep learning–based method for sufficient detectionofintracranialaneurysmsfrom3DTOFdatahasnotyet been reported, to our knowledge.”
BackgroundYushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 1×
“org).(22) Intrarater reliability was studied using the”
N4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073 · cited 1×
“uk/ fsl/fslwiki/BET)(20) and performing N4 bias correction.(21)”
Family history of subarachnoid haemorrhage: supplemental value of scrutinizing all relatives.
Greebe, P., Bromberg, J. E., Rinkel, G. J., Algra, A., & van Gijn, J. (1997) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.62.3.273 · Cited by 4,139
Wiebers, D. O. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13860-3 · Cited by 3,905
Efficient multi-scale 3D CNN with fully connected CRF for accurate brain lesion segmentation
Kamnitsas, K., Ledig, C., Newcombe, V. F. J., Simpson, J. P., Kane, A. D., Menon, D. K., Rueckert, D., & Glocker, B. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.10.004 · Cited by 3,498 · cited 4×
“A training batch is built by extracting segments with 50% probability centered on the foreground or background voxels, facilitating an automatic method for balancing the distribution of training samples regarding the size of the desired class in the segment and therefore preventing class imbalance by adjusting to the…”
MethodInfluentialMetrics for evaluating 3D medical image segmentation: analysis, selection, and tool
Taha, A. A., & Hanbury, A. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0068-x · Cited by 2,920
Vlak, M. H., Algra, A., Brandenburg, R., & Rinkel, G. J. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70109-0 · Cited by 2,075 · cited 1×
“It is estimated that approximately 3% of healthy adults have an intracranial aneurysm.(1) These aneurysms often remain undiagnosed unless they become symptomatic (eg, by compression of adjacent neural structures or rupture into the subarachnoid space).”
BackgroundNieuwkamp, D. J., Setz, L. E., Algra, A., Linn, F. H., de Rooij, N. K., & Rinkel, G. J. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70126-7 · Cited by 1,507 · cited 3×
“DSCs differed significantly among preprocessing models A0, B0, C0, and D0 ( (cid:2) 2 [3] (cid”
BackgroundMethodInfluential
Cited by
IntrA: 3D Intracranial Aneurysm Dataset for Deep Learning
Yang, X., Xia, D., Kin, T., & Igarashi, T. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.00273 · Cited by 99
“There are many reports of automatic diagnosis and segmentation of aneurysms based on medical images, including intracranial aneurysm (IA) and abdominal aortic aneurysm (AAA) [24, 30, 37]; however, few reports have been published based on 3D models.”
Background
Metadata
- Authors
- Sichtermann, T., Faron, A., Sijben, R., Teichert, N., Freiherr, J., & Wiesmann, M.
- Venue
- American Journal of Neuroradiology
- Published
- 2018-12-20
- Volume
- 40
- Issue
- 1
- Pages
- 25-32
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2904807675
- Cited by
- 171
- References
- 23
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep Learning–Based Detection of Intracranial Aneurysms in 3D TOF-MRA. https://app.cochat.ai/papers/10.3174/ajnr.a5911
- The paper
- Sichtermann, T., Faron, A., Sijben, R., Teichert, N., Freiherr, J., & Wiesmann, M. (2019). Deep Learning–Based Detection of Intracranial Aneurysms in 3D TOF-MRA. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a5911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.