The DOI matches its Crossref record.
Human Influenza Resulting from Aerosol Inhalation
Abstract
Volunteers were given A2 influenza virus in a small-particle aerosol. Infection and typical influenza resulted from low doses of virus administered in this manner. Low levels of serum neutralizing antibody were not completely effective in preventing infection and illness. The human infectious dose of this influenza strain when administered by aerosol to subjects free of serum neutralizing antibody was approximately 3 TCID50.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Transmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Incubation periods of acute respiratory viral infections: a systematic review
Lessler, J., Reich, N. G., Brookmeyer, R., Perl, T. M., Nelson, K. E., & Cummings, D. A. (2009) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(09)70069-6 · Cited by 883
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Recognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Metadata
- Authors
- Alford, R. H., Kasel, J. A., Gerone, P. J., & Knight, V.
- Venue
- Experimental Biology and Medicine
- Publisher
- Frontiers Media SA
- Published
- 1966-07-01
- Volume
- 122
- Issue
- 3
- Pages
- 800-804
- ISSN
- 0071-3384 (ISSN-L)
- 1535-3702
- 1535-3699
- OpenAlex
- W1988795185
- Cited by
- 363
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Influenza Resulting from Aerosol Inhalation. https://app.cochat.ai/papers/10.3181/00379727-122-31255
- The paper
- Alford, R. H., Kasel, J. A., Gerone, P. J., & Knight, V. (1966). Human Influenza Resulting from Aerosol Inhalation. Experimental Biology and Medicine. https://doi.org/10.3181/00379727-122-31255
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.