The DOI matches its Crossref record.
Catheterization of the Right Auricle in Man
Abstract
Forssmann first used catheterization of the right heart on himself, after exposure of a vein of the arm by a surgeon. Numerous other investigators since have used right heart catheterization for visualization of the right chamber of the heart and pulmonary vascular trees by means of contrast substance. The introduction of the Robb and Steinberg method, however, renders this method unnecessary for the latter purpose. Collection of right heart blood by catheterization of the right auricle for determining cardiac output in man is mentioned by Grollman, who discredits it because of the possible dangers and numerous misleading factors associated with it. In animal experimentation it is widely used and its innocuity established. Because it is apparently the soundest method for obtaining mixed venous blood for respiratory gas determinations, and because of the numerous problems of hemodynamics it might help solve, a method of right heart catheterization was developed which attempts to overcome objections to former methods. The principal objections included the possibility of venous thrombi and thrombophlebitis that might be associated with introduction of a foreign body in the blood stream, the formation of thrombi within the catheter, and the psychic effects accompanying the procedure with possible alterations in the cardiac output. The following equipment was used in our method: a specially made 10 gauge Lindeman type of needle; a 3-way stopcock with a Luer lock, tightly fitting adapter; a No. 8 French flexible radiopaque ureteral catheter with 2 holes, one at the rounded tip and another about 1 cm from the tip. The catheter is silk with a smooth varnish finish. A saline reservoir with rubber tubing and clamp for controlling the rate of flow was also used. Under the strictest asepsis a nick is made in the skin over the median basilic vein of either the right or left arm after a preliminary infiltration with 2% novocain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Tale of Coronary Artery Disease and Myocardial Infarction
Nabel, E. G., & Braunwald, E. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1112570 · Cited by 994
Bing, R. J., Siegel, A., Ungar, I., & Gilbert, M. (1954) · The American Journal of Medicine · doi:10.1016/0002-9343(54)90365-4 · Cited by 439
Primary pulmonary hypertension
Dresdale, D. T., Schultz, M., & Michtom, R. J. (1951) · The American Journal of Medicine · doi:10.1016/0002-9343(51)90020-4 · Cited by 399
Merrill, A. J. (1946) · Journal of Clinical Investigation · doi:10.1172/jci101720 · Cited by 357
Ha, K., Zhang, W., Jang, H., Kang, S., Wang, L., Tan, P., Hwang, H., & Lu, N. (2021) · Advanced Materials · doi:10.1002/adma.202103320 · Cited by 354
Metadata
- Authors
- Cournand, A., & Ranges, H. A.
- Venue
- Experimental Biology and Medicine
- Publisher
- Frontiers Media SA
- Published
- 1941-03-01
- Volume
- 46
- Issue
- 3
- Pages
- 462-466
- ISSN
- 0071-3384 (ISSN-L)
- 1535-3702
- 1535-3699
- OpenAlex
- W2315885060
- Cited by
- 450
- References
- 0
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Catheterization of the Right Auricle in Man. https://app.cochat.ai/papers/10.3181/00379727-46-12029
- The paper
- Cournand, A., & Ranges, H. A. (1941). Catheterization of the Right Auricle in Man. Experimental Biology and Medicine. https://doi.org/10.3181/00379727-46-12029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.