The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
The Copper T 380 Intrauterine Device: A Summary of Scientific Data
Abstract
Intrauterine devices are the most widely used of all reversible contraceptive methods worldwide. Modern IUDs are among the most effective and long-acting methods of family planning and are acceptable options for many women. This monograph presents highlights of the clinical performance of the Copper T 380 over eight years, including the latest data on effectiveness, expulsions, and continuation rates. It incorporates data from Population Council and World Health Organization studies, and work by scientists at Family Health International and in several countries. Clinical studies of the three models of the Copper T 380 have provided substantial evidence of the safety, effectiveness, convenience, acceptability, and long-acting quality of this IUD. The bulk of the material in this document presents preclinical and clinical performance, including mechanisms of action, effectiveness, outcome of accidental pregnancy, rates of expulsion and ectopic pregnancy, side effects, continuation rates, return to fertility, and lactation and IUD use. There is also discussion of the data on IUD use and pelvic inflammatory disease, and the importance of performing skilled insertions under aseptic conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Jacob, M. (1989) · Health Education Journal · doi:10.1177/001789698904800401 · Cited by 3,090
The Corrosion and Oxidation of Metals: Scientific Principles and Practical Applications
Evans, U. R. (1960) · Cited by 479
Sivin, I., Stern, J., Coutinho, E. M., Mattos, C. E. R., El‐Mahgoub, S., Díaz, S., Pavez, M., Alvarez, F., Brache, V., Thevenin, F., et al. (1991) · Contraception · doi:10.1016/0010-7824(91)90149-a · Cited by 231
Self-citationEvaluation of Intrauterine Devices: Ninth Progress Report of the Cooperative Statistical Program
Tietze, C., & Lewit, S. (1970) · Studies in Family Planning · doi:10.2307/1965076 · Cited by 209
Type of intrauterine device and the risk of pelvic inflammatory disease.
Nc, L., Gl, R., Ory, H. W., & Rt, B. (1983) · PubMed · Cited by 204
Toivonen, J., Luukkainen, T., & Allonen, H. O. (1991) · Obstetrics and Gynecology · doi:10.1097/00006250-199102000-00019 · Cited by 191
Tubal Infertility and the Intrauterine Device
Cramer, D. W., Schiff, I., Schoenbaum, S. C., Gibson, M., Bélisle, S., Albrecht, B. H., Stillman, R. J., Mj, B., Wilson, E. A., Stadel, B. V., et al. (1985) · New England Journal of Medicine · doi:10.1056/nejm198504113121502 · Cited by 190
Contraceptive Failure in the United States: An Update
Trussell, J., Hatcher, R. A., Cates, W., Stewart, F. H., & Kost, K. (1990) · Studies in Family Planning · doi:10.2307/1966591 · Cited by 189
Sivin, I., El‐Mahgoub, S., McCarthy, T., Mishell, D. R., Shoupe, D., Alvarez, F., Brache, V., Jimenez, E., Díaz, J., Faúndes, A., et al. (1990) · Contraception · doi:10.1016/0010-7824(90)90046-x · Cited by 179
Self-citationMeasuring early pregnancy loss: laboratory and field methods
Wilcox, A. J., Weinberg, C. R., WEHMANN, R. E., Armstrong, E. G., Canfield, R. E., & NISULA, B. C. (1985) · Fertility and Sterility · doi:10.1016/s0015-0282(16)48862-x · Cited by 129
Cited by
Contraceptive efficacy of intrauterine devices
Thonneau, P. F., & Almont, T. (2008) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2007.10.787 · Cited by 112
Rowe, P. J., Farley, T., Peregoudov, A., Piaggio, G. G., Boccard, S., Landoulsi, S., & Meirik, O. (2016) · Contraception · doi:10.1016/j.contraception.2016.02.024 · Cited by 97
Utility and drawbacks of continuous use of a copper T IUD for 20 years
Sivin, I. (2007) · Contraception · doi:10.1016/j.contraception.2007.01.016 · Cited by 80
Self-citationAnalysis of client characteristics that may affect early discontinuation of the TCu-380A IUD
Rivera, R., Chen-Mok, M., & McMullen, S. L. (1999) · Contraception · doi:10.1016/s0010-7824(99)00077-3 · Cited by 70
Hubacher, D., Reyes, V., y Lillo, S. P., Pierre‐Louis, B. J., Zepeda, A., Chen, P., & Croxatto, H. (2006) · Human Reproduction · doi:10.1093/humrep/del029 · Cited by 54
The use of vaginal ultrasound to identify copper T IUDs at high risk of expulsion
Petta, C. A., Faundes, D. G., Pimentel, E., Díaz, J., & Bahamondes, L. G. (1996) · Contraception · doi:10.1016/s0010-7824(96)00181-3 · Cited by 47
(1994) · Contraception · doi:10.1016/0010-7824(94)90094-9 · Cited by 47
IUD expulsion solved with implant technology
Kets, H. V., Wildemeersch, D. A., Pas, H. V. D., Vrijens, M., Trappen, Y. V., Delbarge, W., Temmerman, M., Batár, I., Barri, P. N., Martínez, F., et al. (1995) · Contraception · doi:10.1016/0010-7824(94)00013-m · Cited by 27
Contraceptive efficacy of the Copper T380A and the Multiload Cu250 IUD in three developing countries
Farr, G., & Amatya, R. N. (1994) · Advances in Contraception · doi:10.1007/bf01978107 · Cited by 25
Contraceptive devices: intravaginal and intrauterine delivery systems
Benagiano, G., Gabelnick, H. L., & Farris, M. (2008) · Expert Review of Medical Devices · doi:10.1586/17434440.5.5.639 · Cited by 25
Five-year clinical experiences with NOVA T®380 copper IUD
Batár, I., Kuukankorpi, A., Siljander, M., Elomaa, K., & Rauramo, I. (2002) · Contraception · doi:10.1016/s0010-7824(02)00385-2 · Cited by 25
Wildemeersch, D. A., Schacht, E. H., & Wildemeersch, P. (2001) · The European Journal of Contraception & Reproductive Health Care · doi:10.1080/713604262 · Cited by 24
Farr, G., Rivera, R., & Amatya, R. N. (1998) · Advances in Contraception · doi:10.1023/a:1006575610716 · Cited by 18
An analysis of the personal reasons for discontinuing IUD use
Petta, C. A., Amatya, R. N., Farr, G., & Chi, I. (1994) · Contraception · doi:10.1016/0010-7824(94)90021-3 · Cited by 18
Intrauterine contraceptives that do not fit well contribute to early discontinuation
Wildemeersch, D. A. (2011) · The European Journal of Contraception & Reproductive Health Care · doi:10.3109/13625187.2010.546533 · Cited by 17
Wildemeersch, D. A., & Andrade², A. C. S. (2010) · Gynecological Endocrinology · doi:10.3109/09513591003632308 · Cited by 16
Hubacher, D., Schreiber, C. A., Turok, D. K., Jensen, J. T., Creinin, M. D., Nanda, K., White, K. O., Dayananda, I., Teal, S. B., Chen, P., et al. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101554 · Cited by 16
Farr, G., Amatya, R. N., Delgado Betancourt, J., David, M., Alfonso, L. A., & Dacalos, E. (1994) · Contraception · doi:10.1016/0010-7824(94)90059-0 · Cited by 16
Wildemeersch, D. A., Schacht, E. H., & Wildemeersch, P. (2002) · Contraception · doi:10.1016/s0010-7824(02)00324-4 · Cited by 15
Reinprayoon, D., Gilmore, C., Farr, G., & Amatya, R. N. (1998) · Contraception · doi:10.1016/s0010-7824(98)00097-3 · Cited by 14
Clinical performance of the TCu 380A and Lippes Loop IUDs in three developing countries
Farr, G., Amatya, R. N., Acosta, M., Ekwempu, C. C., & Kisninci, H. (1995) · Contraception · doi:10.1016/0010-7824(95)00119-u · Cited by 13
The Copper-T 380A IUD: A ten-year alternative to female sterilisation in India
Iyengar, K., & Iyengar, S. D. (2000) · Reproductive Health Matters · doi:10.1016/s0968-8080(00)90194-0 · Cited by 12
Wildemeersch, D. A., & Schacht, E. H. (2000) · The European Journal of Contraception & Reproductive Health Care · doi:10.1080/13625180008500399 · Cited by 11
Two-year clinical experience with Nova-T 380, a novel copper–silver IUD
Batár, I., Kuukankorpi, A., Rauramo, I., & Siljander, M. (1999) · Advances in Contraception · doi:10.1023/a:1006631511642 · Cited by 10
Clinical evaluation of the TCu 380A IUD at six Latin American centers
Petta, C. A., Amatya, R. N., & Farr, G. (1994) · Contraception · doi:10.1016/0010-7824(94)90077-9 · Cited by 9
Birth Control and Family Planning Using Intrauterine Devices (IUDs)
Iliescu, G. D., Tudorache, Ş., Vlădăreanu, S., Oprescu, N. D., Mureșan, M. C., Drăguşin, R. C., & Ceauşu, I. (2018) · InTech eBooks · doi:10.5772/intechopen.72242 · Cited by 9
Intrauterine devices: learning from the past and looking to the future
Petta, C. A., McPheeters, M. L., & Chi, I. (1996) · Journal of Biosocial Science · doi:10.1017/s0021932000022276 · Cited by 9
Current assessment of the use of intrauterine devices
Westhoff, C. L. (1996) · Journal of Nurse-Midwifery · doi:10.1016/0091-2182(96)00015-8 · Cited by 7
An evaluation of the Copper-T 380A IUD's safety and efficacy at three African centers
Farr, G., Amatya, R. N., Doh, A. S., Ekwempu, C. C., Toppozada, M., & Ruminjo, J. K. (1996) · Contraception · doi:10.1016/s0010-7824(96)00063-7 · Cited by 7
Intrauterine systems: a frameless future?
Wildemeersch, D. A., Goldstuck, N. D., & Hasskamp, T. (2016) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2016.1162153 · Cited by 6
Ali, R. A. M. (2012) · IHI Repository · Cited by 6
Wildemeersch, D. A., Schacht, E. H., Thiéry, M., & Kets, H. V. (2000) · The European Journal of Contraception & Reproductive Health Care · doi:10.1080/13625180008500400 · Cited by 5
Zinc as a non-hormonal contraceptive: a better alternative to the copper intrauterine device (IUD)
Shankie-Williams, K., Lindsay, L., Murphy, C., & Dowland, S. (2022) · doi:10.1101/2022.03.24.485705 · Cited by 3
Use of the Intrauterine Device by Inner-city Women
Sarma, S. P. (1998) · Archives of Family Medicine · doi:10.1001/archfami.7.2.130 · Cited by 2
Metadata
- Authors
- Sivin, I., Greenslade, F., Schmidt, F. H., & Waldman, S. N.
- Affiliations
- Population Council (IN)
- Publisher
- Population Council
- Published
- 1992
- OpenAlex
- W2724587284
- Cited by
- 33
- References
- 92
- Citations by year
- 2022: 1 · 2018: 1 · 2016: 2 · 2012: 1
- Type
- report
- Language
- en
- Open access
- closed
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Reproductive Health and Contraception
- Social Sciences › Political Science and International Relations › International Human Rights and Reproductive Law
- Health Sciences › Medicine › Urology › Male Reproductive Health Studies
- Keywords
- intrauterine devices, contraceptive effectiveness, IUD expulsion, continuation rate, ectopic pregnancy, unintended pregnancy, IUD side effects, return to fertility, lactation, pelvic inflammatory disease, long-acting reversible contraception
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.