The DOI matches its Crossref record.
Poisson's Ratio in Skin
Abstract
Poisson's ratio of cow teat skin was measured uni- and biaxially and shown to be anisotropic and dependent on aspect ratio. At strains below 0.1 (where Cauchy and Hencky strain are indistinguishable) the Poisson's ratio of cow teat skin measured biaxially is very much greater than 1.0, whereas the Poisson's ratio of distending artery is between 0.5 and 0.3. Knitted fabric behaves similarly to cow teat skin in that it can give a negative Poisson's ratio at low strains. Skin is therefore probably to be considered mechanically as an open feltwork of fibres rather than some sort of continuum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Auxetic metamaterials and structures: a review
Ren, X., Das, R., Tran, P., Ngo, T. D., & Xie, Y. M. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aaa61c · Cited by 1,277
Auxetic mechanical metamaterials
Kolken, H. M. A., & Zadpoor, A. A. (2017) · RSC Advances · doi:10.1039/c6ra27333e · Cited by 788
Negative poisson’s ratio in single-layer black phosphorus
Jiang, J.-W., & Park, H. S. (2014) · Nature Communications · doi:10.1038/ncomms5727 · Cited by 774
Dental Functional Morphology: How Teeth Work
Lucas, P. W. (2004) · doi:10.1017/cbo9780511735011 · Cited by 550
Negative-Poisson's-Ratio Materials: Auxetic Solids
Lakes, R. S. (2017) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070616-124118 · Cited by 455
Manufacturing, characteristics and applications of auxetic foams: A state-of-the-art review
Jiang, W., Ren, X., Wang, S. L., Zhang, X. G., Zhang, X. Y., Luo, C., Xie, Y. M., Scarpa, F., Alderson, A., & Evans, K. E. (2022) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2022.109733 · Cited by 284
Metadata
- Authors
- Lees, C., Vincent, J. F. V., & Hillerton, J. E.
- Venue
- Bio-Medical Materials and Engineering
- Publisher
- SAGE Publications
- Published
- 1991
- Volume
- 1
- Issue
- 1
- Pages
- 19-23
- ISSN
- 0959-2989 (ISSN-L)
- OpenAlex
- W4293874423
- Cited by
- 192
- References
- 0
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.