The DOI matches its Crossref record.
Ultrasound contrast agents as markers of vascularity and microcirculation
Abstract
Ultrasound contrast agents contain tiny gas-filled microbubbles which on intravenous injection are transported like red blood cells by the bloodstream. They are distributed to the entire macro- and microvascular system without extravasation (blood-pool tracer). Contrast-specific ultrasound modalities allow selective imaging of these microbubble contrast agents in real time, with excellent separation from underlying tissue signals. The dynamic wash-in and wash-out of a contrast bolus allows the detection and quantitative assessment of vascular flow and parenchymal perfusion. On complete filling of vascular structures the microbubble distribution delineates the vascular lumen and depicts the vascular architecture, down to tiny branches within parenchymal tissue. Mathematical models for bolus kinetics and flash/replenishment kinetics allow precise quantification of relative blood volume and blood flow, with high temporal and spatial resolution. Contrast-enhanced ultrasound examinations can be repeated at short intervals and performed at the bedside, making this diagnostic method convenient for guidance of interventions and therapy monitoring. Future applications include the use of microbubbles as target-specific molecular imaging agents and as delivery systems for local drug and gene therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Metadata
- Authors
- Greis, C.
- Venue
- Clinical Hemorheology and Microcirculation
- Publisher
- SAGE Publications
- Published
- 2009-01
- Volume
- 43
- Issue
- 1-2
- Pages
- 1-9
- ISSN
- 1386-0291 (ISSN-L)
- 1875-8622
- OpenAlex
- W1559958337
- Cited by
- 162
- References
- 0
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound contrast agents as markers of vascularity and microcirculation. https://app.cochat.ai/papers/10.3233/ch-2009-1216
- The paper
- Greis, C. (2009). Ultrasound contrast agents as markers of vascularity and microcirculation. Clinical Hemorheology and Microcirculation. https://doi.org/10.3233/ch-2009-1216
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.