Critical issues in bioartificial liver development
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
End-stage liver disease accounts for over 30,000 deaths annually in the United States. Orthotopic liver transplantation is the only clinically proven treatment for patients with end-stage liver failure. A limitation of this therapy is a shortage of donor organs available. This donor organ shortage is exacerbated by the fact that the number of patients listed for transplantation has continued to increase. As a result, there has been a continuing increase in the number of patients who die waiting for a donor liver. Extracorporeal bioartificial liver devices consisting of viable hepatocytes have the potential to provide temporary support for patients with fulminant hepatic failure, thereby serving as a "bridge" to transplantation. In some patients, this temporary support would allow the native liver to regenerate function, eliminating the need for transplantation and the resulting life-long immunosuppressive therapy, all of which translates into a cost savings to the health care system. Although the bioartificial liver device is a promising technology for the treatment of liver failure, significant technical challenges remain in order to develop systems with sufficient processing capacity and of manageable size. An overview of the critical issues in the development of bioartificial liver devices is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liver from bone marrow in humans
Theise, N. D., Nimmakayalu, M., Gardner, R., Illei, P. B., Morgan, G., Teperman, L., Henegariu, O., & Krause, D. S. (2000) · Hepatology · doi:10.1053/jhep.2000.9124 · Cited by 1,210 · cited 2×
“The existence of hepatic stem cells was hypothesized over 40 years ago [61], and recent data suggest that there are stem cells present within [62–64] as well as outside the liver [65] which can differentiate into fully mature hepatocytes.”
Prevention of acute liver failure in rats with reversibly immortalized human hepatocytes
Kobayashi, N., Fujiwara, T., Westerman, K. A., Inoue, Y., Sakaguchi, M., Noguchi, H., Miyazaki, M., Cai, J., Tanaka, N., Fox, I. J., et al. (2000) · Science · doi:10.1126/science.287.5456.1258 · Cited by 331
Cited by
Maguire, T., Novik, E., Schloss, R., & Yarmush, M. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20748 · Cited by 159
“…of effective extracorporeal bioartificial liver devices (Demetriou et al., 2004; Hochleitner et al., 2005; Rahman et al., 2004; Shito et al., 2003; Tilles et al., 2002a,b; van de Kerkhove et al., 2004; Yarmush et al., 1992a,b; Zeilinger et al., 2004), in vitro systems for pharmaceutical…”
BackgroundSelf-citationBioartificial livers: a review of their design and manufacture
Tuerxun, K., He, J., Ibrahim, I., Yusupu, Z., Yasheng, A., Xu, Q., Tang, R., Aikebaier, A., Wu, Y., Tuerdi, M., et al. (2022) · Biofabrication · doi:10.1088/1758-5090/ac6e86 · Cited by 24
“Assuming that the minimum cell mass to rescue a patient from ALF is about 5%–10% of the total liver weight, at least 1 × 10 10 cells are required in BAL systems to achieve an ideal therapeutic effect, which remains a formidable challenge [159].”
Stem Cell-Based Strategies: The Future Direction of Bioartificial Liver Development
Feng, L., Wang, Y., Fu, Y., Li, T., & He, G. (2024) · Stem Cell Reviews and Reports · doi:10.1007/s12015-023-10672-5 · Cited by 9
“Studies have shown that at least 1 × 10 10 cells are required in BAL systems to achieve an ideal therapeutic effect, which is a great challenge [175, 176].”
Lu, J., Zhu, D., & Li, L. (2022) · The International Journal of Artificial Organs · doi:10.1177/03913988211066502 · Cited by 3
Metadata
- Authors
- Tilles, A. W., Berthiaume, F., Yarmush, M. L., & Toner, M.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 2002-07-08
- Volume
- 10
- Issue
- 3-4
- Pages
- 177-186
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W1741084120
- Cited by
- 34
- References
- 2
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.