Concordance Analysis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In this article, we describe qualitative and quantitative methods for assessing the degree of agreement (concordance) between two measuring or rating techniques. An assessment of concordance is particularly important when a new measuring technique is introduced. METHODS: We give an example to illustrate a number of simple methods of comparing different measuring or rating techniques, and we explain the underlying principle of each method. We also give further illustrative examples from medical research papers that were retrieved by a selective literature search. RESULTS: Methods of comparing different measuring or rating techniques are of two kinds: those with a nominal rating scale and those with a continuous rating scale. We only discuss methods for comparing one measuring or rating technique with another one. Moreover, we point out some common erroneous approaches to concordance analysis. CONCLUSION: Concordance analysis is needed to establish the validity of a new diagnostic measuring or rating technique or to demonstrate the near-equivalence of multiple measuring or rating techniques. Erroneous approaches to concordance analysis can lead to false conclusions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Research works printed but not linked: 8
- Tetzlaff R, Schwarz T, Kauczor HU, Meinzer HP, Puderbach M, Eichinger M: Lung function measurement of single lungs by lung area segmentation on 2D dynamic MRI. Acad Radiol. 2010; 17: 496–503. · doi:10.1016/j.acra.2009.11.009
- Altman DG: Practical statistics for medical research. 1st edition. Oxford: Chapman and Hall 1991; 1–611.
- Altman DG, Bland JM: Measurement in medicine: the analysis of method comparison studies. The Statistician 1983; 32: 307–17. · DOI · Paper page
- Song JW, Oh YM, Shim TS, Kim WS, Ryu JS, Choi CM: Efficacy comparison between (18)F-FDG PET/CT and bone scintigraphy in detecting bony metastases of non-small-cell lung cancer. Lung Cancer 2009; 65: 333–8. · DOI
- du Prel JB, Hommel G, Röhrig B, Blettner M: Confidence interval or p-value? Part 4 of a series on evaluation of scientific publications. Dtsch Arztebl Int 2009; 106(19): 335–9. · DOI · Paper page
- Bortz J, Lienert G A, Boehnke K: Verteilungsfreie Methoden in der Biostatistik. 3rd Edition. Heidelberg: Springer 2008; 1–929.
- Hilgers R D, Bauer P, Scheiber V: Einführung in die Medizinische Statistik. 2nd edition. Heidelberg: Springer 2007.
- Altman DG, Machin D, Bryant TN, Gardner MJ: Statistics with confidence. 2nd edition. London: BMJ Books 2000.
Cited by
Verma, N., Buch, B., Taralekar, R., & Acharya, S. (2023) · JMIR Formative Research · doi:10.2196/42775 · Cited by 30
Metadata
- Authors
- Kwiecien, R., Kopp-Schneider, A., & Blettner, M.
- Venue
- Deutsches Ärzteblatt international
- Publisher
- Deutscher Arzte-Verlag GmbH
- Published
- 2011-07-29
- Volume
- 108
- Issue
- 30
- Pages
- 515-21
- ISSN
- 1866-0452 (ISSN-L)
- OpenAlex
- W2154842668
- Cited by
- 162
- References
- 1
- FWCI
- 3.38
- Type
- journal article
- Language
- de
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.