Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 389

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen

Open access
Bamford, J, Fortnum, H, Bristow, K, Smith, J, Vamvakas, G, Davies, L, Taylor, R, Watkin, P, Fonseca, S, Davis, A, Hind, s·2007·Health Technology Assessment

Abstract

OBJECTIVES: To describe and analyse in detail current practice of school entry hearing screening (SES) in the UK. DATA SOURCES: Main electronic databases were searched up to May 2005. REVIEW METHODS: A national postal questionnaire survey was addressed to all leads for SES in the UK, considering current practice in terms of implementation, protocols, target population and performance data. Primary data from cohort studies in one area of London were examined. A systematic review of alternative SES tests, test performance and impact on outcomes was carried out. Finally, a review of published studies on costs, plus economic modelling of current and alternative programmes was prepared. RESULTS: The survey suggested that SES is used in most of England, Wales and Scotland; just over 10% of respondents have abandoned the screen; others are awaiting national guidance. Coverage of SES is variable, but is often over 90% for children in state schools. Referral rates are variable, with a median of about 8%. The test used for the screen is the pure tone sweep test but with wide variation in implementation, with differing frequencies, pass criteria and retest protocols; written examples of protocols were often poor and ambiguous. There is no national approach to data collection, audit and quality assurance, and there are variable approaches at local level. The screen is performed in less than ideal test conditions and resources are often limited, which has an impact on the quality of the screen. The primary cohort studies show that the prevalence of permanent childhood hearing loss continues to increase through infancy. Of the 3.47 in 1000 children with a permanent hearing loss at school screen age, 1.89 in 1000 required identification after the newborn screen. Newborn hearing screening is likely to reduce significantly the yield of SES for permanent bilateral and unilateral hearing impairments; yield had fallen from about 1.11 in 1000 before newborn screening to about 0.34 in 1000 for cohorts that had had newborn screening, of which only 0.07 in 1000 were unilateral impairments. Just under 20% of permanent moderate or greater bilateral, mild bilateral and unilateral impairments, known to services as 6-year-olds or older, remained to be identified around the time of school entry. No good-quality published comparative trials of alternative screens or tests for SES were identified and studies concerned with the relative accuracy of alternative tests are difficult to compare and often flawed by differing referral criteria and case definitions; with full pure tone audiometry as the reference test, the pure tone sweep test appears to have high sensitivity and high specificity for minimal, mild and greater hearing impairments, better than alternative tests for which evidence was identified. There is insufficient evidence regarding possible harm of the screen. There were no published studies identified that examined the possible effects of SES on longer term outcomes. No good-quality published economic evaluations of SES were identified and a universal SES based on pure tone sweep tests was associated with higher costs and slightly higher quality-adjusted life-years (QALYs) compared with no screen and other screen alternatives; the incremental cost-effectiveness ratio for such a screen is around 2500 pounds per QALY gained; the range of expected costs, QALYs and net benefits was broad, indicating a considerable degree of uncertainty. Targeted screening could be more cost-effective than universal school entry screening; however, the lack of primary data and the wide limits for variables in the modelling mean that any conclusions must be considered indicative and exploratory only. A national screening programme for permanent hearing impairment at school entry meets all but three of the criteria for a screening programme, but at least six criteria are not met for screening for temporary hearing impairment. CONCLUSIONS: The lack of good-quality evidence in this area remains a serious problem. Services should improve quality and audit screen performance for identification of previously unknown permanent hearing impairment, pending evidence-based policy decisions based on the research recommendations. Further research is needed into a number of important areas including the evaluation of an agreed national protocol for services delivering SES to make future studies and audits of screen performance more directly comparable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta11320

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 389

Metadata

Authors
Bamford, J., Fortnum, H., Bristow, K., Smith, J., Vamvakas, G., Davies, L., Taylor, R., Watkin, P., Fonseca, S., Davis, A., & Hind, S.
Venue
Health Technology Assessment
Published
2007-08
Volume
11
Issue
32
Pages
1-168, iii
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2162065677
Cited by
389
References
1
FWCI
9.28
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen. https://app.cochat.ai/papers/10.3310/hta11320
The paper
Bamford, J., Fortnum, H., Bristow, K., Smith, J., Vamvakas, G., Davies, L., Taylor, R., Watkin, P., Fonseca, S., Davis, A., & Hind, S. (2007). Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen. Health Technology Assessment. https://doi.org/10.3310/hta11320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.