The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Blood glucose self-monitoring in type 2 diabetes: a randomised controlled trial
Open accessAbstract
OBJECTIVES: To determine whether self-monitoring of blood glucose (SMBG), either alone or with additional instruction in incorporating the results into self-care, is more effective than usual care in improving glycaemic control in non-insulin-treated diabetes. DESIGN: An open, parallel group randomised controlled trial. SETTING: 24 general practices in Oxfordshire and 24 in South Yorkshire, UK. PARTICIPANTS: Patients with non-insulin-treated type 2 diabetes, aged > or = 25 years and with glycosylated haemoglobin (HbA1c) > or = 6.2%. INTERVENTIONS: A total of 453 patients were individually randomised to one of: (1) standardised usual care with 3-monthly HbA1c (control, n = 152); (2) blood glucose self-testing with patient training focused on clinician interpretation of results in addition to usual care (less intensive self-monitoring, n = 150); (3) SMBG with additional training of patients in interpretation and application of the results to enhance motivation and maintain adherence to a healthy lifestyle (more intensive self-monitoring, n = 151). MAIN OUTCOME MEASURES: The primary outcome was HBA1c at 12 months, and an intention-to-treat analysis, including all patients, was undertaken. Blood pressure, lipids, episodes of hypoglycaemia and quality of life, measured with the EuroQol 5 dimensions (EQ-5D), were secondary measures. An economic analysis was also carried out, and questionnaires were used to measure well-being, beliefs about use of SMBG and self-reports of medication taking, dietary and physical activities, and health-care resource use. RESULTS: The differences in 12-month HbA1c between the three groups (adjusted for baseline HbA1c) were not statistically significant (p = 0.12). The difference in unadjusted mean change in HbA1c from baseline to 12 months between the control and less intensive self-monitoring groups was -0.14% [95% confidence interval (CI) -0.35 to 0.07] and between the control and more intensive self-monitoring groups was -0.17% (95% CI -0.37 to 0.03). There was no evidence of a significantly different impact of self-monitoring on glycaemic control when comparing subgroups of patients defined by duration of diabetes, therapy, diabetes-related complications and EQ-5D score. The economic analysis suggested that SMBG resulted in extra health-care costs and was unlikely to be cost-effective if used routinely. There appeared to be an initial negative impact of SMBG on quality of life measured on the EQ-5D, and the potential additional lifetime gains in quality-adjusted life-years, resulting from the lower levels of risk factors achieved at the end of trial follow-up, were outweighed by these initial impacts for both SMBG groups compared with control. Some patients felt that SMBG was helpful, and there was evidence that those using more intensive self-monitoring perceived diabetes as having more serious consequences. Patients using SMBG were often not clear about the relationship between their behaviour and the test results. CONCLUSIONS: While the data do not exclude the possibility of a clinically important benefit for specific subgroups of patients in initiating good glycaemic control, SMBG by non-insulin-treated patients, with or without instruction in incorporating findings into self-care, did not lead to a significant improvement in glycaemic control compared with usual care monitored by HbA1c levels. There was no convincing evidence to support a recommendation for routine self-monitoring of all patients and no evidence of improved glycaemic control in predefined subgroups of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736
Methods for the Economic Evaluation of Health Care Programmes
Drummond, M. E., Sculpher, M. J., Torrance, G. W., O’Brien, B. J., & Stoddart, G. L. (2005) · doi:10.1093/oso/9780198529446.001.0001 · Cited by 13,648
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Evaluating non-randomised intervention studies
Deeks, J., Dinnes, J., D'Amico, R., Sowden, A., Sakarovitch, C., Song, F., Petticrew, M., & Altman, D. (2003) · Health Technology Assessment · doi:10.3310/hta7270 · Cited by 2,907
Bellg, A. J., Treatment Fidelity Workgroup of the NIH Behavior Change Consortium, Borrelli, B., Resnick, B., Hecht, J., Minicucci, D. S., Ory, M., Ogedegbe, G., Orwig, D., Ernst, D., et al. (2004) · Health Psychology · doi:10.1037/0278-6133.23.5.443 · Cited by 2,620
The summary of diabetes self-care activities measure: results from 7 studies and a revised scale.
Toobert, D. J., Hampson, S. E., & Glasgow, R. E. (2000) · Diabetes Care · doi:10.2337/diacare.23.7.943 · Cited by 2,561
Self-Management Education for Adults With Type 2 Diabetes
Norris, S. L., Lau, J., Smith, S. J., Schmid, C. H., & Engelgau, M. M. (2002) · Diabetes Care · doi:10.2337/diacare.25.7.1159 · Cited by 1,750
Evaluating patient-based outcome measures for use in clinical trials.
Fitzpatrick, Davey, Buxton, & Jones (1998) · Health Technology Assessment · doi:10.3310/hta2140 · Cited by 1,715
Qualitative research methods in health technology assessment: a review of the literature.
Murphy, Dingwall, Greatbatch, Parker, & Watson (1998) · Health Technology Assessment · doi:10.3310/hta2160 · Cited by 1,107
Cited by
Ibanez, B., James, S., Agewall, S., Antunes, M. J., Bucciarelli-Ducci, C., Bueno, H., Caforio, A. L. P., Crea, F., Goudevenos, J. A., Halvorsen, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx393 · Cited by 9,728
Cosentino, F., Grant, P. J., Aboyans, V., Bailey, C. J., Ceriello, A., Delgado, V., Federici, M., Filippatos, G., Grobbee, D. E., Hansen, T. B., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz486 · Cited by 4,763
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht108 · Cited by 1,955
(2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.10.013 · Cited by 609
Dineen-Griffin, S., Garcia-Cardenas, V., Williams, K., & Benrimoj, S. I. (2019) · PLoS ONE · doi:10.1371/journal.pone.0220116 · Cited by 639
Metadata
- Authors
- Farmer, A., Wade, A., French, D., Simon, J., Yudkin, P., Gray, A., Craven, A., Goyder, L., Holman, R., Mant, D., Kinmonth, A., & Neil, H.
- Venue
- Health Technology Assessment
- Published
- 2009-02
- Volume
- 13
- Issue
- 15
- Pages
- iii-iv, ix
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W1972407383
- Cited by
- 180
- References
- 25
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- diamond
- Funders
- Health Technology Assessment programme (01/38/05)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood glucose self-monitoring in type 2 diabetes: a randomised controlled trial. https://app.cochat.ai/papers/10.3310/hta13150
- The paper
- Farmer, A., Wade, A., French, D., Simon, J., Yudkin, P., Gray, A., Craven, A., Goyder, L., Holman, R., Mant, D., Kinmonth, A., & Neil, H. (2009). Blood glucose self-monitoring in type 2 diabetes: a randomised controlled trial. Health Technology Assessment. https://doi.org/10.3310/hta13150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.