Evaluation of droplet dispersion during non-invasive ventilation, oxygen therapy, nebuliser treatment and chest physiotherapy in clinical practice: implications for management of pandemic influenza and other airborne infections
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Influenza viruses are thought to be spread by droplets, but the role of aerosol dissemination is unclear and has not been assessed by previous studies. Oxygen therapy, nebulised medication and ventilatory support are treatments used in clinical practice to treat influenzal infection are thought to generate droplets or aerosols. OBJECTIVES: Evaluation of the characteristics of droplet/aerosol dispersion around delivery systems during non-invasive ventilation (NIV), oxygen therapy, nebuliser treatment and chest physiotherapy by measuring droplet size, geographical distribution of droplets, decay in droplets over time after the interventions were discontinued. METHODS: Three groups were studied: (1) normal controls, (2) subjects with coryzal symptoms and (3) adult patients with chronic lung disease who were admitted to hospital with an infective exacerbation. Each group received oxygen therapy, NIV using a vented mask system and a modified circuit with non-vented mask and exhalation filter, and nebulised saline. The patient group had a period of standardised chest physiotherapy treatment. Droplet counts in mean diameter size ranges from 0.3 to > 10 µm were measured with an counter placed adjacent to the face and at a 1-m distance from the subject/patient, at the height of the nose/mouth of an average health-care worker. RESULTS: NIV using a vented mask produced droplets in the large size range (> 10 µm) in patients (p = 0.042) and coryzal subjects (p = 0.044) compared with baseline values, but not in normal controls (p = 0.379), but this increase in large droplets was not seen using the NIV circuit modification. Chest physiotherapy produced droplets predominantly of > 10 µm (p = 0.003), which, as with NIV droplet count in the patients, had fallen significantly by 1 m. Oxygen therapy did not increase droplet count in any size range. Nebulised saline delivered droplets in the small- and medium-size aerosol/droplet range, but did not increase large-size droplet count. CONCLUSIONS: NIV and chest physiotherapy are droplet (not aerosol)-generating procedures, producing droplets of > 10 µm in size. Due to their large mass, most fall out on to local surfaces within 1 m. The only device producing an aerosol was the nebuliser and the output profile is consistent with nebuliser characteristics rather than dissemination of large droplets from patients. These findings suggest that health-care workers providing NIV and chest physiotherapy, working within 1 m of an infected patient should have a higher level of respiratory protection, but that infection control measures designed to limit aerosol spread may have less relevance for these procedures. These results may have infection control implications for other airborne infections, such as severe acute respiratory syndrome and tuberculosis, as well as for pandemic influenza infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Intensive care management of coronavirus disease 2019 (COVID-19): challenges and recommendations
Phua, J., Weng, L., Ling, L., Egi, M., Lim, C.-M., Divatia, J. V., Shrestha, B. R., Arabi, Y. M., Ng, J., Gomersall, C. D., et al. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30161-2 · Cited by 1,509
Halpin, D. M. G., Criner, G. J., Papi, A., Singh, D., Anzueto, A., Martinez, F. J., Agusti, A. A., & Vogelmeier, C. F. (2021) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202009-3533so · Cited by 760
Coughs and Sneezes: Their Role in Transmission of Respiratory Viral Infections, Including SARS-CoV-2
Dhand, R., & Li, J. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202004-1263pp · Cited by 409
Managing ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
Aerosol Transmission of Infectious Disease
Jones, R. M., & Brosseau, L. M. (2015) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000448 · Cited by 380
Prachand, V. N., Milner, R., Angelos, P., Posner, M. C., Fung, J. J., Agrawal, N., Jeevanandam, V., & Matthews, J. B. (2020) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2020.04.011 · Cited by 356
Ko, F. W., Chan, K. P., Hui, D. S., Goddard, J. R., Shaw, J. G., Reid, D. W., & Yang, I. A. (2016) · Respirology · doi:10.1111/resp.12780 · Cited by 354
European Resuscitation Council COVID-19 guidelines executive summary
Nolan, J. P., Monsieurs, K. G., Bossaert, L., Böttiger, B. W., Greif, R., Lott, C., Madar, J., Olasveengen, T. M., Roehr, C. C., Semeraro, F., et al. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.06.001 · Cited by 347
“Chest compressions are similar to some chest physiotherapy techniques, which are associated with aerosol generation.(27) Furthermore, the person performing chest compressions is close to the patient’s airway.”
BackgroundNosocomial Transmission of Emerging Viruses via Aerosol-Generating Medical Procedures
Judson, S. D., & Munster, V. J. (2019) · Viruses · doi:10.3390/v11100940 · Cited by 294
Safety and Efficacy of Chest Physiotherapy in Patients With COVID-19: A Critical Review
Abdullahi, A. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00454 · Cited by 79
Sleep and COVID-19: considerations about immunity, pathophysiology, and treatment.
(2020) · PubMed Central · doi:10.5935/1984-0063.20200062 · Cited by 77
“However, this intentional leak means that non-invasive ventilation is an aerosol-generating therapy, and exhaled particles may remain in the air for more than one hour and increase the risk of contamination to people in the same area 76,77 .”
BackgroundSleep medicine and COVID-19. Has a new era begun?
Voulgaris, A., Ferini-Strambi, L., & Steiropoulos, P. (2020) · Sleep Medicine · doi:10.1016/j.sleep.2020.07.010 · Cited by 54
“In a previous study [6] enrolling three groups: (a) patients with infective acute exacerbation of chronic lung disease, (b) patients with coryzal symptoms, and (c) normal controls; use of vented NIV with full face mask in form of BPAP was associated with increased spread of large droplets (>10 mm), and not of aerosols…”
Influential
Metadata
- Authors
- Simonds, A., Hanak, A., Chatwin, M., Morrell, M., Hall, A., Parker, K., Siggers, J., & Dickinson, R.
- Venue
- Health Technology Assessment
- Published
- 2010-10
- Volume
- 14
- Issue
- 46
- Pages
- 131-172
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W1963650240
- Cited by
- 246
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.