CoChat

Bone-anchored hearing aids (BAHAs) for people who are bilaterally deaf: a systematic review and economic evaluation

Open access
Colquitt, JL, Jones, J, Harris, P, Loveman, E, Bird, A, Clegg, AJ, Baguley, DM, Proops, DW, Mitchell, TE, Sheehan, PZ, Welch, K · 2011 · Health Technology Assessment
Cited by 90

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: A bone-anchored hearing aid (BAHA) consists of a permanent titanium fixture, which is surgically implanted into the skull bone behind the ear, and a small detachable sound processor that clips onto the fixture. BAHAs are suitable for people with conductive or mixed hearing loss who cannot benefit fully from conventional hearing aids. OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness of BAHAs for people who are bilaterally deaf. DATA SOURCES: Nineteen electronic resources, including MEDLINE, EMBASE and The Cochrane Library (inception to November 2009). Additional studies were sought from reference lists and clinical experts. REVIEW METHODS: Inclusion criteria were applied by two reviewers independently. Data extraction and quality assessment were undertaken by one reviewer and checked by a second. Prospective studies of adults or children with bilateral hearing loss were eligible. Comparisons were BAHAs versus conventional hearing aids [air conduction hearing aid (ACHA) or bone conduction hearing aid (BCHA)], unaided hearing and ear surgery; and unilateral versus bilateral BAHAs. Outcomes included hearing measures, validated measures of quality of life (QoL), adverse events and measures of cost-effectiveness. For the review of cost-effectiveness, full economic evaluations were eligible. RESULTS: Twelve studies were included (seven cohort pre-post studies and five cross-sectional 'audiological comparison' studies). No prospective studies comparing BAHAs with ear surgery were identified. Overall quality was rated as weak for all included studies and meta-analysis was not possible due to differences in outcome measures and patient populations. There appeared to be some audiological benefits of BAHAs compared with BCHAs and improvements in speech understanding in noise compared with ACHAs; however, ACHAs may produce better audiological results for other outcomes. The limited evidence reduces certainty. Hearing is improved with BAHAs compared with unaided hearing. Improvements in QoL with BAHAs were identified by a hearing-specific instrument but not generic QoL measures. Studies comparing unilateral with bilateral BAHAs suggested benefits of bilateral BAHAs in many, but not all, situations. Prospective case series reported between 6.1% and 19.4% loss of implants. Most participants experienced no or minor skin reactions. A decision analytic model was developed. Costs and benefits of unilateral BAHAs were estimated over a 10-year time horizon, applying discount rates of 3.5%. The incremental cost per user receiving BAHA, compared with BCHA, was £ 16,409 for children and £ 13,449 for adults. In an exploratory analysis the incremental cost per quality-adjusted life-year (QALY) gained was between £ 55,642 and £ 119,367 for children and between £ 46,628 and £ 100,029 for adults for BAHAs compared with BCHA, depending on the assumed QoL gain and proportion of each modelled cohort using their hearing aid for ≥ 8 or more hours per day. Deterministic sensitivity analysis suggested that the results were highly sensitive to the assumed proportion of people using BCHA for ≥ 8 hours per day, with very high incremental cost-effectiveness ratio values (£ 500,000-1,200,000 per QALY gained) associated with a high proportion of people using BCHA. More acceptable values (£ 15,000-37,000 per QALY gained) were associated with a low proportion of people using BCHA for ≥ 8 hours per day (compared with BAHA). LIMITATIONS: The economic evaluation presented in this report is severely limited by a lack of robust evidence on the outcome of hearing aid provision. This has lead to a more restricted analysis than was originally anticipated (limited to a comparison of BAHA and BCHA). In the absence of useable QoL data, the cost-effectiveness analysis is based on potential utility gains from hearing, that been inferred using a QoL instrument rather than measures reported by hearing aid users themselves. As a result the analysis is regarded as exploratory and the reported results should be interpreted with caution. CONCLUSIONS: Exploratory cost-effectiveness analysis suggests that BAHAs are unlikely to be a cost-effective option where the benefits (in terms of hearing gain and probability of using of alternative aids) are similar for BAHAs and their comparators. The greater the benefit from aided hearing and the greater the difference in the proportion of people using the hearing aid for ≥ 8 hours per day, the more likely BAHAs are to be a cost-effective option. The inclusion of other dimensions of QoL may also increase the likelihood of BAHAs being a cost-effective option. A national audit of BAHAs is needed to provide clarity on the many areas of uncertainty surrounding BAHAs. Further research into the non-audiological benefits of BAHAs, including QoL, is required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta15260

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 90

Metadata

Authors
Colquitt, J., Jones, J., Harris, P., Loveman, E., Bird, A., Clegg, A., Baguley, D., Proops, D., Mitchell, T., Sheehan, P., & Welch, K.
Venue
Health Technology Assessment
Published
2011-07
Volume
15
Issue
26
Pages
1-200, iii
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2020991269
Cited by
90
References
2
FWCI
0.58
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.