CoChat

Screening for fragile X syndrome: a literature review and modelling study

Open access
Song, F, Barton, P, Sleightholme, V, Yao, G, Fry-Smith, A · 2003 · Health Technology Assessment
Cited by 113

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To compare the effectiveness, estimate the associated costs, and summarise available evidence about the feasibility and acceptability of different screening strategies in England and Wales. Also to establish a model for estimating effectiveness and costs of these different strategies. DATA SOURCES: Literature searches were restricted to MEDLINE and EMBASE, as well as citations in included papers. A broad search strategy was used involving all aspects of fragile X syndrome (FXS) and covered all relevant literature published between 1991 and 2001. REVIEW METHODS: An assessment was conducted of published literature and efforts focused on the development of a model that could be used to synthesise data from various sources, estimate cost-effectiveness of different strategies, and conduct sensitivity analyses according to different assumptions. RESULTS: The identified screening programmes were effective in detecting carriers, but a comparison of different strategies was not possible. Simulation results by the FXS Model showed that, over the first 10 years, 4% of premutation (PM) females and 70% of full mutation (FM) females could be detected by active cascade screening; it is 10% and 58%, respectively, by prenatal screening. The maximal detection rate for FM carriers by active cascade screening is higher than that by prenatal screening (91% versus 71%). However, the maximal rate of detection of female PM carriers by active cascade screening (6%) is much lower than that by prenatal screening (60%). During the first 10 years of simulation, the estimated direct cost per year to the NHS in England and Wales is 0.7-0.2 million pounds sterling by active cascade screening and 14.5-9.1 million pounds sterling by a programme of prenatal screening. The incremental cost per extra carrier detected (using current practice as the reference standard) is on average only 165 pounds sterling by active cascade screening and 7543 pounds sterling by prenatal screening. The incremental cost per FXS birth avoided is on average 8494 pounds sterling by active cascade screening and 284,779 pounds sterling by prenatal screening. CONCLUSIONS: The empirical evidence suggests that both prenatal screening and cascade screening are feasible and acceptable. Population-based prenatal screening is more efficacious, but it will cost more than active cascade screening. The active cascade screening of affected families is more efficient, cheaper, but less effective than a population-based prenatal screening. It is suggested that both strategies be evaluated in large-scale trials, which might also help to determine whether and how the different strategies could be simultaneously or sequentially combined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta7160

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 113

Metadata

Authors
Song, F., Barton, P., Sleightholme, V, Yao, G., & Fry-Smith, A.
Venue
Health Technology Assessment
Published
2003-08
Volume
7
Issue
16
Pages
1-106
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2040316692
Cited by
113
References
4
FWCI
1.51
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.