Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Clinical effectiveness and cost-effectiveness of neonatal screening for inborn errors of metabolism using tandem mass spectrometry: a systematic review

Open access
Pandor, A, Eastham, J, Beverley, C, Chilcott, J, Paisley, S · 2004 · Health Technology Assessment

Abstract

OBJECTIVES: To evaluate the clinical and cost-effectiveness of tandem mass spectrometry (MS)-based neonatal screening for inborn errors of metabolism (IEM). DATA SOURCES: Fourteen electronic bibliographic databases covering biomedical, science, economic and grey literature, the reference lists of relevant articles and abstracts of conference proceedings and 18 health services research-related resources. REVIEW METHODS: This review is an update of two previous HTA reports of neonatal screening for IEM. These reports have been updated by a systematic review of published research (between 1995 and January 2002) on neonatal screening of inherited metabolic disorders using tandem MS. This was supplemented by a search for economic literature and the application of a modelling exercise to investigate the economics of using tandem MS within a neonatal screening programme in the UK. RESULTS: Evidence from the reviews of IEM found that the UK screening programme for phenylketonuria (PKU) was well established and there was universal agreement that neonatal screening for PKU was justified. Of the many other disorders that can be detected by tandem MS, the best candidate condition for a new screening programme was medium-chain acyl-coenzyme A dehydrogenase (MCAD) deficiency. For many other IEM that can be detected by tandem MS, robust clinical evidence was limited. Cost-effectiveness analysis using economic modelling indicated that substituting the use of tandem MS for existing technologies for the screening of PKU alone could not be justified. However, results from the economic modelling indicate that the addition of screening for MCAD deficiency as part of a neonatal screening programme for PKU using tandem MS would be economically attractive. Using an operational range of 50,000-60,000 specimens per system per year, the mean incremental cost for PKU and MCAD deficiency screening combined using tandem MS from the model was -23,312 British pounds for each cohort of 100,000 neonates screened. This cost saving is associated with a mean incremental gain of 59 life-years. Additional economic modelling using the available evidence does not support including other inherited metabolic diseases within a neonatal screening programme at present. CONCLUSIONS: The evidence appears to support the introduction of tandem MS into a UK neonatal screening programme for PKU and MCAD deficiency combined. Tandem MS has the potential for simultaneous multi-disease screening using a single analytical technique. Although the marginal cost of extending the programme to include other conditions may be relatively small, the application of this new technology to PKU and MCAD deficiency screening does not imply the wholesale inclusion of all disorders detectable by tandem MS. It is suggested that the primary focus of further research should be on the long-term effectiveness of treatment strategies on adverse outcomes (disabilities and impairments) under conventional management and the potential impact of early diagnosis using tandem MS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta8120

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 201

Metadata

Authors
Pandor, A., Eastham, J., Beverley, C., Chilcott, J., & Paisley, S.
Venue
Health Technology Assessment
Published
2004-03
Volume
8
Issue
12
Pages
iii, 1-121
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2041422879
Cited by
201
References
2
FWCI
1.55
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical effectiveness and cost-effectiveness of neonatal screening for inborn errors of metabolism using tandem mass spectrometry: a systematic review. https://app.cochat.ai/papers/10.3310/hta8120
The paper
Pandor, A., Eastham, J., Beverley, C., Chilcott, J., & Paisley, S. (2004). Clinical effectiveness and cost-effectiveness of neonatal screening for inborn errors of metabolism using tandem mass spectrometry: a systematic review. Health Technology Assessment. https://doi.org/10.3310/hta8120

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.