Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record.

Newborn screening for congenital heart defects: a systematic review and cost-effectiveness analysis

Open access
Knowles, R, Griebsch, I, Dezateux, C, Brown, J, Bull, C, Wren, C·2005·Health Technology Assessment

Abstract

OBJECTIVES: To provide evidence to inform policy decisions about the most appropriate newborn screening strategy for congenital heart defects, identifying priorities for future research that might reduce important uncertainties in the evidence base for such decisions. DATA SOURCES: Electronic databases. Groups of parents and health professionals. REVIEW METHODS: A systematic review of the published medical literature concerning outcomes for children with congenital heart defects was carried out. A decision analytic model was developed to assess the cost-effectiveness of alternative screening strategies for congenital heart defects relevant to the UK. A further study was then carried out using a self-administered anonymous questionnaire to explore the perspectives of parents and health professionals towards the quality of life of children with congenital heart defects. The findings from a structured review of the medical literature regarding parental experiences were linked with those from a focus group of parents of children with congenital heart defects. RESULTS: Current newborn screening policy comprises a clinical examination at birth and 6 weeks, with specific cardiac investigations for specified high-risk children. Routine data are lacking, but under half of affected babies, not previously identified antenatally or because of symptoms, are identified by current newborn screening. There is evidence that screen-positive infants do not receive timely management. Pulse oximetry and echocardiography, in addition to clinical examination, are alternative newborn screening strategies but their cost-effectiveness has not been adequately evaluated in a UK setting. In a population of 100,000 live-born infants, the model predicts 121 infants with life-threatening congenital heart defects undiagnosed at screening, of whom 82 (68%) and 83 (69%) are detected by pulse oximetry and screening echocardiography, respectively, but only 39 (32%) by clinical examination alone. Of these, 71, 71 and 34, respectively, receive a timely diagnosis. The model predicts 46 (0.5%) false-positive screening diagnoses per 100,000 infants with clinical examination, 1168 (1.3%) with pulse oximetry and 4857 (5.4%) with screening echocardiography. The latter includes infants with clinically non-significant defects. Total programme costs are predicted of pound 300,000 for clinical examination, pound 480,000 for pulse oximetry and pound 3.54 million for screening echocardiography. The additional cost per additional timely diagnosis of life-threatening congenital heart defects ranges from pound 4900 for pulse oximetry to pound 4.5 million for screening echocardiography. Including clinically significant congenital heart defects gives an additional cost per additional diagnosis of pound 1500 for pulse oximetry and pound 36,000 for screening echocardiography. Key determinants for cost-effectiveness are detection rates for pulse oximetry and screening echocardiography. Parents and health professionals place similar values on the quality of life outcomes of children with congenital heart defects and both are more averse to neurological than to cardiac disability. Adverse psychosocial effects for parents are focused around poor management and/or false test results. CONCLUSIONS: Early detection through newborn screening potentially can improve the outcome of congenital heart defects; however the current programme performs poorly, and lacks monitoring of quality assurance, performance management and longer term outcomes. Pulse oximetry is a promising alternative newborn screening strategy but further evaluation is needed to obtain more precise estimates of test performance and to inform optimal timing, diagnostic and management strategies. Although screening echocardiography is associated with the highest detection rate, it is the most costly strategy and has a 5% false-positive rate. Improving antenatal detection of congenital heart defects increases the cost per timely postnatal diagnosis afforded by any newborn screening strategy but does not alter the relative effects of the strategies. An improvement of timely management of screen positive infants is essential. Further research is required to refine the detection rate and other aspects of pulse oximetry, to evaluate antenatal screening strategies more directly, and to investigate the psychosocial effects of newborn screening for congenital heart defects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta9440

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 252

Metadata

Authors
Knowles, R., Griebsch, I., Dezateux, C., Brown, J., Bull, C., & Wren, C.
Venue
Health Technology Assessment
Published
2005-11
Volume
9
Issue
44
Pages
1-152, iii
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2136369416
Cited by
252
References
0
FWCI
1.02
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Newborn screening for congenital heart defects: a systematic review and cost-effectiveness analysis. https://app.cochat.ai/papers/10.3310/hta9440
The paper
Knowles, R., Griebsch, I., Dezateux, C., Brown, J., Bull, C., & Wren, C. (2005). Newborn screening for congenital heart defects: a systematic review and cost-effectiveness analysis. Health Technology Assessment. https://doi.org/10.3310/hta9440

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.