Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 301

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Towards evidence-based guidelines for the prevention of venous thromboembolism: systematic reviews of mechanical methods, oral anticoagulation, dextran and regional anaesthesia as thromboprophylaxis

Open access
Roderick, P, Ferris, G, Wilson, K, Halls, H, Jackson, D, Collins, R, Baigent, C·2005·Health Technology Assessment

Abstract

OBJECTIVES: To assess the benefits in terms of reductions in the risks of deep vein thrombosis (DVT) and of pulmonary embolism (PE), and hazards in terms of major bleeding, of: (i) mechanical compression; (ii) oral anticoagulants; (iii) dextran; and (iv) regional anaesthesia (as an alternative to general anaesthesia) in surgical and medical patients. DATA SOURCES: Electronic databases, search of Antithrombotic Trialists' Collaboration database, contact with trialists and manufacturers. REVIEW METHODS: All trials identified as fitting the selection criteria were independently assessed. The primary outcomes were DVT, PE and major bleeding events, and proximal venous thrombosis (PVT) and fatal PE were secondary outcomes. Trials were subdivided into those that had assessed a method as the only means of thromboprophylaxis ('monotherapy') and those that had assessed the effects of adding a method to another form of thromboprophylaxis ('adjunctive therapy'). RESULTS: Mechanical compression methods reduced the risk of DVT by about two-thirds when used as monotherapy and by about half when added to a pharmacological method. These benefits were similar irrespective of the particular method used (graduated compression stockings, intermittent pneumatic compression or footpumps) and were similar in each of the surgical groups studied. Mechanical methods reduced the risk of PVT by about half and the risk of PE by two-fifths. Oral anticoagulants, when used as monotherapy, reduced the risk of DVT and of PVT by about half, and this protective effect appeared similar in each of the surgical groups studied. There was an apparently large four-fifths reduction in the role of PE, but not only was the magnitude of this reduction statistically uncertain, but also pulmonary embolism was reported by a minority of trials, so it may be subject to selection bias. Oral anticoagulant regimens approximately doubled the risk of major bleeding and appeared less effective at preventing DVT than heparin regimens, although were associated with less major bleeding. Dextran reduced the risk of DVT and of PVT by about half, again irrespective of the type of surgery, but too few studies had reported PE to provide reliable estimates of effect on this outcome. Dextran appeared to be less effective at preventing DVT than the heparin regimens studied. Dextran was associated with an increased risk of bleeding, but too few bleeds had occurred for the size of this excess risk to be estimated reliably. Compared with general anaesthesia, regional anaesthesia reduced the risk of DVT by about half, and this benefit appeared similar in each of the surgical settings studied. Regional anaesthesia was associated with less major bleeding than general anaesthesia. CONCLUSIONS: In the absence of a clear contraindication (such as severe peripheral arterial disease), patients undergoing a surgical procedure would be expected to derive net benefit from a mechanical compression method of thromboprophylaxis (such as graduated compression stockings), irrespective of their absolute risk of venous thromboembolism. Patients who are considered to be at particularly high risk of venous thromboembolism may also benefit from a pharmacological thromboprophylactic agent, but since oral anticoagulant and dextran regimens appear less effective at preventing DVT than standard low-dose unfractionated heparin or low molecular weight heparin regimens, they may be less suitable for patients at high risk of venous thromboembolism, even though they are associated with less bleeding. Whenever feasible, the use of regional anaesthesia as an alternative to general anaesthesia may also provide additional protection against venous thromboembolism. There is little information on the prevention of venous thromboembolism among high-risk medical patients (such as those with stroke), so further randomised trials in this area would be helpful.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta9490

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 301

Metadata

Authors
Roderick, P., Ferris, G., Wilson, K., Halls, H., Jackson, D., Collins, R., & Baigent, C.
Venue
Health Technology Assessment
Published
2005-12
Volume
9
Issue
49
Pages
iii-iv, ix
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2022950741
Cited by
301
References
36
FWCI
1.79
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.