The DOI matches its Crossref record.
Eculizumab prevents intravascular hemolysis in patients with paroxysmal nocturnal hemoglobinuria and unmasks low-level extravascular hemolysis occurring through C3 opsonization
Open accessAbstract
BACKGROUND: Paroxysmal nocturnal hemoglobinuria is an acquired hemolytic anemia characterized by intravascular hemolysis which has been demonstrated to be effectively controlled with eculizumab. However, lactate dehydrogenase levels remain slightly elevated and haptoglobin levels remain low in some patients suggesting residual low-level hemolysis. This may be due to C3-mediated clearance of paroxysmal nocturnal hemoglobinuria red blood cells through the reticuloendothelial system. DESIGN AND METHODS: Thirty-nine samples from patients not treated with eculizumab and 31 samples from patients treated with eculizumab were obtained (for 17 of these 31 samples there were also samples taken prior to eculizumab treatment). Membrane bound complement was assessed by flow cytometry. Direct antiglobulin testing was carried out using two methods. Lactate dehydrogenase was assayed to assess the degree of hemolysis. RESULTS: Three of 39 patients (8%) with paroxysmal nocturnal hemoglobinuria not on eculizumab had a positive direct antiglobulin test, while the test was positive in 21 of 31 (68%) during eculizumab treatment. Of these 21 patients who had a positive direct antiglobulin test during eculizumab treatment, 17 had been tested prior to treatment; only one was positive. Flow cytometry using anti-C3 monoclonal antibodies was performed on the 21 direct antiglobulin test-positive, eculizumab-treated patients; the median proportion of C3-positive total red blood cells was 26%. Among the eculizumab-treated patients, 16 of the 21 (76.2%) with a positive direct antiglobulin test received at least one transfusion compared with one of ten (10.0%) of those with a negative test (P<0.01). Among the eculizumab-treated patients, the mean hemoglobin value for the 21 with a positive direct antiglobulin test was 9.6+/-0.3 g/dL, whereas that in the ten patients with a negative test was 11.0+/-0.4 g/dL (P=0.02). CONCLUSIONS: These data demonstrate a previously masked mechanism of red cell clearance in paroxysmal nocturnal hemoglobinuria and suggests that blockade of complement at C5 allows C3 fragment accumulation on some paroxysmal nocturnal hemoglobinuria red cells, explaining the residual low-level hemolysis occurring in some eculizumab-treated patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paroxysmal nocturnal hemoglobinuria
Brodsky, R. A. (2014) · Blood · doi:10.1182/blood-2014-02-522128 · Cited by 648
Kelly, R. J., Hill, A., Arnold, L. M., Brooksbank, G. L., Richards, S. J., Cullen, M., Mitchell, L. D., Cohen, D. R., Gregory, W. M., & Hillmen, P. (2011) · Blood · doi:10.1182/blood-2011-02-333997 · Cited by 526
Self-citationLiao, D. S., Grossi, F. V., El Mehdi, D., Gerber, M. R., Brown, D. M., Heier, J. S., Wykoff, C. C., Singerman, L. J., Abraham, P., Grassmann, F., et al. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.011 · Cited by 519
Thrombosis in paroxysmal nocturnal hemoglobinuria
Hill, A., Kelly, R. J., & Hillmen, P. (2013) · Blood · doi:10.1182/blood-2012-09-311381 · Cited by 478
Self-citationParoxysmal nocturnal haemoglobinuria
Hill, A., DeZern, A. E., Kinoshita, T., & Brodsky, R. A. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.28 · Cited by 448
Self-citation
Metadata
- Authors
- Hill, A., Rother, R. P., Arnold, L., Kelly, R., Cullen, M. J., Richards, S. J., & Hillmen, P.
- Venue
- Haematologica
- Published
- 2010-02-09
- Volume
- 95
- Issue
- 4
- Pages
- 567-573
- ISSN
- 0390-6078 (ISSN-L)
- 1592-8721
- OpenAlex
- W2145490488
- Cited by
- 197
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Eculizumab prevents intravascular hemolysis in patients with paroxysmal nocturnal hemoglobinuria and unmasks low-level extravascular hemolysis occurring through C3 opsonization. https://app.cochat.ai/papers/10.3324/haematol.2009.007229
- The paper
- Hill, A., Rother, R. P., Arnold, L., Kelly, R., Cullen, M. J., Richards, S. J., & Hillmen, P. (2010). Eculizumab prevents intravascular hemolysis in patients with paroxysmal nocturnal hemoglobinuria and unmasks low-level extravascular hemolysis occurring through C3 opsonization. Haematologica. https://doi.org/10.3324/haematol.2009.007229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.