CoChat

Quality of Drinking-water at Source and Point-of-consumption - Drinking Cup As a High Potential Recontamination Risk: A Field Study in Bolivia

Open access
Rufener, Simonne, Mäusezahl, Daniel, Mosler, Hans-Joachim, Weingartner, Rolf · 2010 · Journal of Health, Population and Nutrition
Cited by 149

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In-house contamination of drinking-water is a persistent problem in developing countries. This study aimed at identifying critical points of contamination and determining the extent of recontamination after water treatment. In total, 81 households were visited, and 347 water samples from their current sources of water, transport vessels, treated water, and drinking vessels were analyzed. The quality of water was assessed using Escherichia coli as an indicator for faecal contamination. The concentration of E. coli increased significantly from the water source [median=0 colony-forming unit (CFU)/100 mL, interquartile range (IQR: 0–13)] to the drinking cup (median=8 CFU/100 mL; IQR: 0–550; n=81, z=−3.7, p<0.001). About two-thirds (34/52) of drinking vessels were contaminated with E. coli. Although boiling and solar disinfection of water (SODIS) improved the quality of drinking-water (median=0 CFU/100 mL; IQR: 0–0.05), recontamination at the point-of-consumption significantly reduced the quality of water in the cups (median=8, IQR: 0–500; n=45, z=−2.4, p=0.015). Home-based interventions in disinfection of water may not guarantee health benefits without complementary hygiene education due to the risk of post-treatment contamination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3329/jhpn.v28i1.4521

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 149

Metadata

Authors
Rufener, S., Mäusezahl, D., Mosler, H.-J., & Weingartner, R.
Venue
Journal of Health, Population and Nutrition
Published
2010-03-03
Volume
28
Issue
1
Pages
34-41
ISSN
1606-0997 (ISSN-L)
OpenAlex
W2118837440
Cited by
149
References
3
FWCI
3.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality of Drinking-water at Source and Point-of-consumption - Drinking Cup As a High Potential Recontamination Risk: A Field Study in Bolivia. https://app.cochat.ai/papers/10.3329/jhpn.v28i1.4521
The paper
Rufener, S., Mäusezahl, D., Mosler, H.-J., & Weingartner, R. (2010). Quality of Drinking-water at Source and Point-of-consumption - Drinking Cup As a High Potential Recontamination Risk: A Field Study in Bolivia. Journal of Health, Population and Nutrition. https://doi.org/10.3329/jhpn.v28i1.4521

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.