An Innovative PN HPT™-based Medical Device for the Therapy of Deteriorated Periocular Skin Quality
Open accessAbstract
Objective: Polynucleotides Highly Purified Technology (PN HPT™) hydrate the extracellular matrix and fill the depressed dermal spaces in the periocular areas with skin quality problems; moreover, PN HPT™ replenish the nucleotide precursor pool. Within a long-term monitoring program, the questionnaire-based survey aimed to confirm the profile of known side effects and contraindications. Methods: Survey base: A real-world cohort of 48 ambulatory outpatients with periocular skin quality problems after a three-session intradermal injection cycle with 15 mg of PN HPT™- based gel in disposable syringes PLINEST eye, Mastelli S.r.l., Sanremo, Italy). Study purpose: Confirming the PN HPT™ persisting efficacy and safety in improving facial and periocular skin quality and texture. Assessment tools: Investigator-assessed Wrinkle Severity Rating Scale (WSRS) and investigator- and subject assessed Global Aesthetic Improvement Scale (GAIS) at baseline and four weeks after the last PN HPT™ intradermal injection. Results: The mean whole-cohort WSRS score improved from 3.3 ± 0.93 at baseline to 1.8 ± 0.90 at the final follow up visit (–45.5%, p<0.0001), including in the 39 cohort outpatients with hypotrophic skin (–46.9%, p<0.0001). According to investigators, 87.5% of cohort subjects and outpatients were GAIS responders, with 50% “Much improved” or “Very much improved”. “Much improved” and “Very much improved” were the self-assessed GAIS ratings for 56.3% of surveyed subjects. Limitations: Brief overall follow-up, lack of a control group. Conclusion: PN HPT™ retain the usual excellent value and safety in improving skin quality in the periocular region with no variations over time and no differences in subjects with correctly structured or hypotrophic skin.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A PN-based medical device incorporating HPT®, developed by Mastelli S.R.L., significantly improved facial wrinkles and skin roughness, as measured using three-dimensional skin imaging and the global esthetic improvement scale (GAIS).
“The use of a PN-based medical device incorporating HPT®, developed by Mastelli S.R.L., significantly improved facial wrinkles and skin roughness, as measured using three-dimensional skin imaging and the global esthetic improvement scale (GAIS) [165,166].”
From Comparison of Polynucleotide and Polydeoxyribonucleotide in Dermatology: Molecular Mechanisms and Clinical Perspectives (2025) · cites this paper as [166]
The Acknowledgements identify Mastelli S.r.l. as the developer, and the Efficacy outcomes report significant improvements in periocular and facial wrinkles assessed with WSRS, alongside favorable GAIS ratings. The paper does not report three-dimensional skin imaging or a separate measure of skin roughness; its assessments were WSRS and GAIS. (LLM, conf=0.88)
Experimental — accuracy not yet measuredPlacentex® is a PDRN-based therapeutic developed by Mastelli S.R.L. in Italy.
“A notable example is Placentex®, a PDRN-based therapeutic developed by Mastelli S.R.L. in Italy.”
From Comparison of Polynucleotide and Polydeoxyribonucleotide in Dermatology: Molecular Mechanisms and Clinical Perspectives (2025) · cites this paper as [166]
The Acknowledgements (page unavailable) say that Mastelli S.r.l. in Italy developed the PN HPT™ technology and the injectable periocular gel tested in this study. The Methods identify that product as PLINEST eye, not Placentex®. Our copy does not identify Placentex® or describe it as PDRN-based, so the claim about that specific therapeutic is unsupported. (LLM, conf=0.82)
Experimental — accuracy not yet measuredPlacentex® is manufactured using a proprietary High Purification Technology (HPT) designed to enhance purity and partially control the polymer length.
“This product is manufactured using a proprietary High Purification Technology (HPT) designed to enhance purity and partially control the polymer length [165,166].”
From Comparison of Polynucleotide and Polydeoxyribonucleotide in Dermatology: Molecular Mechanisms and Clinical Perspectives (2025) · cites this paper as [166]
The Introduction describes a patented purification process that produces a pure ingredient with polynucleotide fragments of 50–2,000 base pairs, supporting the purity and polymer-length portions of the claim. But the paper identifies the studied product as PLINEST eye (Abstract), not Placentex®, and does not establish that Placentex® is manufactured using this technology. Page numbers were not available in our copy. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A Classification of Facial Wrinkles
Lemperle, G., Holmes, R. E., Cohen, S. R., & Lemperle, S. M. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00050 · Cited by 184 · see citing works
Flagged first, then by citations
Research works printed but not linked: 16
- Ziai K, Lighthall JG. Periocular rejuvenation using hyaluronic acid fillers. Plast Aesthet Res. 2020; 7: 53.
- Zein M, Tie-Shue R, Pirakitikulr N, et al. Complications after cosmetic periocular filler: prevention and management. Plast Aesthet Res. 2020; 7: 44.
- Goldie K, Kerscher M, Fabi SG, et al. Skin Quality -A holistic 360° view: consensus results. Clin Cosmet Investig Dermatol. 2021; 14: 643-654.
- Mandal P, Gama F. The use of periocular fillers in aesthetic medicine. J Plast Reconstr Aesthet Surg. 2021; 74: 1602-1609.
- Cavallini M, Bartoletti E, Maioli L. on behalf of The Polynucleotides HPT™ Priming Board, Collegio Italiano delle Società Scientifiche di Medicina Estetica (Italian College of the Aesthetic Medicine Scientific Societies) -SIME, AGORÀ, SIES. Consensus report on the use of PN HPT™ (polynucleotides highly purified technology) in aesthetic medicine. J Cosmet Dermatol. 2021; 20: 922-928.
- Bartoletti E, Cavallini M, Maioli L, et al. Introduction to Polynucleotides Highly Purified Technology. Aesthetic Medicine. 2020; 6: 43-47.
- Palmieri IP, Raichi M. Clinical commentary about foreign body complications over 20 years after polymethyl- methacrylate face implants and control of late sequelae with Polynucleotides Highly Purified Technology (PN HPT™). J Cosmet Dermatol. 2022; 21: 5537-5542.
- Colangelo MT, Govoni P, Belletti S, et al. Polynucleotide biogel enhances tissue repair, matrix deposition and organization. J Biol Regul Homeost Agents. 2021; 35: 355-362.
- De Caridi G, Massara M, Acri I, et al. Trophic effects of polynucleotides and hyaluronic acid in the healing of venous ulcers of the lower limbs: a clinical study. Int Wound J. 2014; 13: 754-758.
- Segreto F, Carotti S, Marangi GF, et al. The use of acellular porcine dermis, hyaluronic acid and polynucleotides in the treatment of cutaneous ulcers: single-blind randomized clinical trial. Int Wound J. 2020; 17: 1702-1708.
- Garratt AM, Helgeland J, Gulbrandsen P. Five-point scales outperform 10-point scales in a randomized comparison of item scaling for the Patient Experiences Questionnaire. J Clin Epidemiol. 2011; 64: 200-207.
- Faul F, Erdfelder E, Buchner A, Lang A-G. Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses. Behav Res Methods. 2009; 41: 1149-1160.
- Mishra P, Singh U, Pandey CM, et al. Application of Student's t-test, analysis of variance, and covariance. Ann Card Anaesth. 2019; 22: 407-411.
- Miksad RA, Abernethy AP. Harnessing the power of real- world evidence (RWE): a checklist to ensure regulatory-grade data quality. Clin Pharmacol Ther. 2018; 103: 202-205.
- Gausas RE. Advances in applied anatomy of the eyelid and orbit. Curr Opin Ophthalmol. 2004; 15: 422-425.
- Shams PN, Ortiz-Pérez S, Joshi N. Clinical anatomy of the periocular region. Facial Plast Surg. 2013; 29: 255-263.
Cited by
Sorted by citations
Kim, S. T. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17081024 · Cited by 18 · see citing works
- Authors
- Palmieri, I. P., Moro, L., Fraone, N., De Luca, C., & Prussia, C.
- Affiliations
- Federico II University Hospital (IT)
- Venue
- Surgical Research
- Publisher
- SciVision Publishers LLC
- Published
- 2023-09-30
- Volume
- 5
- Issue
- 3
- ISSN
- 2689-1093 (ISSN-L)
- OpenAlex
- W4388707566
- Cited by
- 2
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Surgical Research (publishedVersion)
- Topics
- Health Sciences › Medicine › Dermatology › Facial Rejuvenation and Surgery Techniques
- Health Sciences › Medicine › Dermatology › Dermatologic Treatments and Research
- Health Sciences › Medicine › Dermatology › Skin Protection and Aging
- Keywords
- polynucleotides, wrinkle severity, intradermal injection, skin rejuvenation, nucleotide precursors, aesthetic improvement, safety and side effects
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review