Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument
Open accessAbstract
Kinematically aligned total knee arthroplasty (TKA) is a new alignment technique. Kinematic alignment corrects arthritic deformity to the patient's constitutional alignment in order to position the femoral and tibial components, as well as to restore the knee's natural tibial-femoral articular surface, alignment, and natural laxity. Kinematic knee motion moves around a single flexion-extension axis of the distal femur, passing through the center of cylindrically shaped posterior femoral condyles. Since it can be difficult to locate cylindrical axis with conventional instrument, patient-specific instrument (PSI) is used to align the kinematic axes. PSI was recently introduced as a new technology with the goal of improving the accuracy of operative technique, avoiding practical issues related to the complexity of navigation and robotic system, such as the costs and higher number of personnel required. There are several limitations to implement the kinematically aligned TKA with the implant for mechanical alignment. Therefore, it is important to design an implant with the optimal shape for restoring natural knee kinematics that might improve patient-reported satisfaction and function.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There are several available methods for identifying native coronal plane morphology, including generic cartilage wear assumptions, use of long leg radiographs, or methods based on advanced imaging.
“There are several available methods for identifying native coronal plane morphology, including generic cartilage wear assumptions, use of long leg radiographs, or methods based on advanced imaging [12–15].”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [14]
The Preoperative Planning section (Reconstruction of 3D model; page not provided) describes CT-based 3D modelling and discusses MRI as another imaging option, supporting the advanced-imaging part of the claim. Our copy does not describe generic cartilage-wear assumptions or long-leg radiographs as methods for identifying native coronal-plane morphology. (LLM, conf=0.84)
Experimental — accuracy not yet measuredSome methods based on CT or MRI use proprietary algorithms that may not be accessible to all surgeons.
“Some of the methods based on CT or MRI use proprietary algorithms that may not be accessible to all surgeons [14–17].”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [14]
The Preoperative Planning sections describe CT- and MRI-based patient-specific instruments and the use of image-processing software, but do not say that any methods use proprietary algorithms or that those algorithms are inaccessible to surgeons. Searches for proprietary algorithms and software access found no passage addressing that point. (LLM, conf=0.73)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 52
- [1]Cherian JJ Kapadia BH Banerjee S Jauregui JJ Issa K Mont MA Mechanical, anatomical, and kinematic axis in TKA: concepts and practical applications Curr Rev Musculoskelet Med 2014 7 89 95 24671469 PMC4092202
- [2]D'Lima DD Hermida JC Chen PC Colwell CW Jr Polyethylene wear and variations in knee kinematics Clin Orthop Relat Res 2001 392 124 130 11716373
- [3]Sikorski JM Alignment in total knee replacement J Bone Joint Surg Br 2008 90 1121 1127 18757949
- [4]Morgan SS Bonshahi A Pradhan N Gregory A Gambhir A Porter ML The influence of postoperative coronal alignment on revision surgery in total knee arthroplasty Int Orthop 2008 32 639 642 17611758 PMC2551715
- [5]Baker PN van der Meulen JH Lewsey J Gregg PJ The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales J Bone Joint Surg Br 2007 89 893 900 17673581
- [6]Bourne RB Chesworth BM Davis AM Mahomed NN Charron KD Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res 2010 468 57 63 19844772 PMC2795819
- [7]Niki Y Nagai K Sassa T Harato K Suda Y Comparison between cylindrical axis-reference and articular surface-reference femoral bone cut for total knee arthroplasty Knee Surg Sports Traumatol Arthrosc 2017 25 3741 3746 27485125
- [8]Bonner TJ Eardley WG Patterson P Gregg PJ The effect of postoperative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years J Bone Joint Surg Br 2011 93-B 1217 1222 21911533
- [9]Luyckx T Vanhoorebeeck F Bellemans J Should we aim at undercorrection when doing a total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 2015 23 1706 1712 25056740
- [10]Parratte S Pagnano MW Trousdale RT Berry DJ Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements J Bone Joint Surg Am 2010 92 2143 2149 20844155
- [11]Vanlommel L Vanlommel J Claes S Bellemans J Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees Knee Surg Sports Traumatol Arthrosc 2013 21 2325 2330 23552665
- [12]Lee SS Lee H Lee DH Moon YW Slight under-correction following total knee arthroplasty for a valgus knee results in similar clinical outcomes Arch Orthop Trauma Surg 2018 138 1011 1019 29770878
- [13]Magnussen RA Weppe F Demey G Servien E Lustig S Residual varus alignment does not compromise results of TKAs in patients with preoperative varus Clin Orthop Relat Res 2011 469 3443 3450 21789710 PMC3210258
- [14]Shelton TJ Nedopil AJ Howell SM Hull ML Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty? Limb and joint line alignment after kinematically aligned total knee arthroplasty Bone Joint J 2017 99-B 1319 1328 28963153
- [15]Miller EJ Pagnano MW Kaufman KR Tibiofemoral alignment in posterior stabilized total knee arthroplasty: static alignment does not predict dynamic tibial plateau loading J Orthop Res 2014 32 1068 1074 24820681
- [16]Calliess T Bauer K Stukenborg-Colsman C Windhagen H Budde S Ettinger M PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study Knee Surg Sports Traumatol Arthrosc 2017 25 1743 1748 27120192
- [17]Waterson HB Clement ND Eyres KS Mandalia VI Toms AD The early outcome of kinematic versus mechanical alignment in total knee arthroplasty: a prospective randomized control trial Bone Joint J 2016 98-B 1360 1368 27694590
- [18]Dossett HG Estrada NA Swartz GJ LeFevre GW Kwasman BG A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results Bone Joint J 2014 96-B 907 913 24986944
- [19]Nam D Nunley RM Barrack RL Patient dissatisfaction following total knee replacement: a growing concern? Bone Joint J 2014 96-B 11 Supple A 96 100 25381418
- [20]Young SW Walker ML Bayan A Briant-Evans T Pavlou P Farrington B The Chitranjan S. Ranawat Award: No difference in 2-year functional outcomes using kinematic versus mechanical alignment in TKA: a randomized controlled clinical trial Clin Orthop Relat Res 2017 475 9 20 27113595 PMC5174030
- [21]Howell SM Howell SJ Kuznik KT Cohen J Hull ML Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 2013 471 1000 1007 22996362 PMC3563808
- [22]Howell SM Papadopoulos S Kuznik K Ghaly LR Hull ML Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty? Int Orthop 2015 39 2117 2124 25823516
- [23]Howell SM Shelton TJ Hull ML Implant survival and function ten years after kinematically aligned total knee arthroplasty J Arthroplasty 2018 33 3678 3684 30122435
- [24]Howell SM Kuznik K Hull ML Siston RA Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients Orthopedics 2008 31 857 863 18814593
- [25]Klatt BA Goyal N Austin MS Hozack WJ Custom-fit total knee arthroplasty (OtisKnee) results in malalignment J Arthroplasty 2008 23 26 29 18165024
- [26]Weber W Weber E Section 4: On the knee Maquet P Furlong R Mechanics of the human walking apparatus Berlin Springer Verlag 1992 75
- [27]Eckhoff DG Bach JM Spitzer VM Reinig KD Bagur MM Baldini TH Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality J Bone Joint Surg Am 2005 87 Suppl 2 71 80 16326726
- [28]Eckhoff D Hogan C DiMatteo L Robinson M Bach J Difference between the epicondylar and cylindrical axis of the knee Clin Orthop Relat Res 2007 461 238 244 17549027
- [29]Hollister AM Jatana S Singh AK Sullivan WW Lupichuk AG The axes of rotation of the knee Clin Orthop Relat Res 1993 290 259 268 8472457
- [30]Iranpour F Merican AM Baena FR Cobb JP Amis AA Patellofemoral joint kinematics: the circular path of the patella around the trochlear axis J Orthop Res 2010 28 589 594 19950364
- [31]Griffin FM Math K Scuderi GR Insall JN Poilvache PL Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees J Arthroplasty 2000 15 354 359 10794232
- [32]Chan WP Lang P Stevens MP Sack K Majumdar S Stoller DW Osteoarthritis of the knee: comparison of radiography, CT, and MR imaging to assess extent and severity AJR Am J Roentgenol 1991 157 799 806 1892040
- [33]Pfitzner T Röhner E Preininger B Perka C Matziolis G Femur positioning in navigated total knee arthroplasty Orthopedics 2012 35 10 Suppl 45 49 23026252
- [34]Ensini A Timoncini A Cenni F Belvedere C Fusai F Leardini A Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement Knee Surg Sports Traumatol Arthrosc 2014 22 621 629 24061719
- [35]Nedopil AJ Howell SM Hull ML What clinical characteristics and radiographic parameters are associated with patellofemoral instability after kinematically aligned total knee arthroplasty? Int Orthop 2017 41 283 291 27619673
- [36]Kim K Kim J Lee D Lim S Eom J The accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty Knee Surg Relat Res 2019 31 19 24 30871288 PMC6425897
- [37]Howell SM Howell SJ Hull ML Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis J Bone Joint Surg Am 2010 92 98 104 20048101
- [38]Johnson JM Mahfouz MR Midilliogğlu MR Nedopil AJ Howell SM Three-dimensional analysis of the tibial resection plane relative to the arthritic tibial plateau in total knee arthroplasty J Exp Orthop 2017 4 27 28791659 PMC5548698
- [39]Nedopil AJ Howell SM Hull ML What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty? Int Orthop 2017 41 1561 1569 28493211
- [40]Ikeuchi M Yamanaka N Okanoue Y Ueta E Tani T Determining the rotational alignment of the tibial component at total knee replacement: a comparison of two techniques J Bone Joint Surg Br 2007 89 45 49 17259415
- [41]Coughlin KM Incavo SJ Churchill DL Beynnon BD Tibial axis and patellar position relative to the femoral epicondylar axis during squatting J Arthroplasty 2003 18 1048 1055 14658111
- [42]Akagi M Matsusue Y Mata T Asada Y Horiguchi M Iida H Effect of rotational alignment on patellar tracking in total knee arthroplasty Clin Orthop Relat Res 1999 366 155 163 10627729
- [43]Rhoads DD Noble PC Reuben JD Mahoney OM Tullos HS The effect of femoral component position on patellar tracking after total knee arthroplasty Clin Orthop Relat Res 1990 260 43 51 2225641
- [44]Steinbrück A Schröder C Woiczinski M Fottner A Müller PE Jansson V The effect of trochlea tilting on patellofemoral contact patterns after total knee arthroplasty: an in vitro study Arch Orthop Trauma Surg 2014 134 867 872 24522864
- [45]Rivière C Iranpour F Harris S Auvinet E Aframian A Parratte S Differences in trochlear parameters between native and prosthetic kinematically or mechanically aligned knees Orthop Traumatol Surg Res 2018 104 165 170 29223778
- [46]Ishikawa M Kuriyama S Ito H Furu M Nakamura S Matsuda S Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: a case study on a single implant design Knee 2015 22 206 212 25813759
- [47]Anouchi YS Whiteside LA Kaiser AD Milliano MT The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens Clin Orthop Relat Res 1993 287 170 177 8448937
- [48]Incavo SJ Schmid S Sreenivas K Ismaily S Noble PC Total knee arthroplasty using anatomic alignment can produce mid-flexion laxity Clin Biomech (Bristol, Avon) 2013 28 429 435 23528629
- [49]Freeman MA Pinskerova V The movement of the normal tibiofemoral joint J Biomech 2005 38 197 208 15598446
- [50]French SR Munir S Brighton R A single surgeon series comparing the outcomes of a cruciate retaining and medially stabilized total knee arthroplasty using kinematic alignment principles J Arthroplasty 2020 35 422 428 31611163
- [51]Schütz P Taylor WR Postolka B Fucentese SF Koch PP Freeman MA Kinematic evaluation of the GMK sphere implant during gait activities: a dynamic video fluoroscopy study J Orthop Res 2019 37 2337 2347 31304995 PMC6851890
- [52]Nicolet-Petersen S Saiz A Shelton T Howell SM Hull ML Small differences in tibial contact locations following kinematically aligned TKA from the native contralateral knee Knee Surg Sports Traumatol Arthrosc 2019 8 13 10.1007/s00167-019-05658-1 [Epub]. Available at: 31410525 · DOI
Cited by
Sorted by citations
Edelstein, A. I., Orsi, A. D., Plaskos, C., Coffey, S., & Suleiman, L. I. (2024) · Arthroplasty · doi:10.1186/s42836-024-00231-9 · Cited by 11 · see citing works
“Some of the methods based on CT or MRI use proprietary algorithms that may not be accessible to all surgeons [14–17].”
Method
- Authors
- Kim, K.-K., Howell, S. M., & Won, Y.-Y.
- Affiliations
- Konyang University (KR)
- University of California, Davis (US)
- Ajou University (KR)
- Corresponding author
- Won, Ye-yeon
- Venue
- Yonsei Medical Journal
- Publisher
- XMLink
- Published
- 2020
- Volume
- 61
- Issue
- 3
- Pages
- 201
- ISSN
- 0513-5796 (ISSN-L)
- 1976-2437
- PMC
- PMC7044694
- OpenAlex
- W3008253625
- Cited by
- 23
- References
- 0
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 2 · 2020: 2 · 2019: 1
- FWCI
- 0.74
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Yonsei Medical Journal (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- AJOU Open Repository (Ajou University) (submittedVersion, cc-by-nc)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- total knee arthroplasty, kinematic alignment, patient-specific instrumentation, knee kinematics, posterior femoral condyle, implant design, knee deformity correction, tibiofemoral alignment
- MeSH terms
- Biomechanical Phenomena, Femur, Humans, Knee Prosthesis, Preoperative Care, Arthroplasty, Replacement, Knee, Osteoarthritis, Knee
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review