CoChat

Compression Garments as Countermeasures to Orthostatic Intolerance

Platts, Steven H., Tuxhorn, Jennifer A., Ribeiro, L. Christine, Stenger, Michael B., Lee, Stuart M.C., Meck, Janice V. · 2009 · Aviation, Space, and Environmental Medicine
Cited by 77

The DOI matches its Crossref record.

Abstract

INTRODUCTION: All astronauts experience some degree of orthostatic intolerance following spaceflight, ranging from tachycardia to orthostatic hypotension and syncope. The purpose of this study was to evaluate the ability of two compression garments, the National Aeronautics and Space Administration's inflatable antigravity suit (AGS) and the Russian Federal Space Agency's non-inflatable compression garment (Kentavr), to prevent hypovolemia-related orthostatic intolerance. METHODS: To mimic the plasma volume loss experienced by astronauts during spaceflight 19 healthy subjects received an intravenous dose of a diuretic, furosemide (0.5 mg x kg(-1)), and then consumed a low-salt diet for 36 h. Thereafter, subjects participated in a 15-min 80 degrees head-up tilt test wearing either the AGS (N = 9) or Kentavr (N = 10). Compression garments were used in the fashion recommended by the respective agencies, delivering approximately 78 mmHg and approximately 30 mmHg of compression in the AGS and Kentavr, respectively. Incidence of presyncope and hemodynamic responses during upright tilt were compared to a separate group of hypovolemic control subjects (N = 16). RESULTS: Subjects wearing the AGS or Kentavr completed the full 15 min of upright tilt without incidence of orthostatic hypotension or presyncope. In contrast, only 9 control subjects (56%) were able to complete the tilt test. In addition, both types of compression garments maintained systolic blood pressure and significantly reduced tilt-induced tachycardia and reductions in stroke volume. CONCLUSIONS: Although both garments successfully countered hypovolemia-induced orthostatic intolerance, the Kentavr provided protection by using lower levels of compression. Determining the optimal compression level required for protection of intolerance may improve crewmember comfort and decrease restrictions on physical activities after spaceflight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3357/asem.2473.2009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 77

Metadata

Authors
Platts, S. H., Tuxhorn, J. A., Ribeiro, L. C., Stenger, M. B., Lee, S. M. C., & Meck, J. V.
Venue
Aviation, Space, and Environmental Medicine
Published
2009-05-01
Volume
80
Issue
5
Pages
437-442
ISSN
  • 0001-9402 (ISSN-L)
  • 0095-6562
OpenAlex
W2088845254
Cited by
77
References
0
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compression Garments as Countermeasures to Orthostatic Intolerance. https://app.cochat.ai/papers/10.3357/asem.2473.2009
The paper
Platts, S. H., Tuxhorn, J. A., Ribeiro, L. C., Stenger, M. B., Lee, S. M. C., & Meck, J. V. (2009). Compression Garments as Countermeasures to Orthostatic Intolerance. Aviation, Space, and Environmental Medicine. https://doi.org/10.3357/asem.2473.2009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.