Stiffness Matters: Fine-Tuned Hydrogel Elasticity Alters Chondrogenic Redifferentiation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Biomechanical cues such as shear stress, stretching, compression and matrix elasticity are considered vital in the establishment of next generation physiological in vitro tissue models. Matrix elasticity, for instance, is known to guide stem cell differentiation, influence healing processes and modulate extracellular matrix (ECM) deposition needed for tissue development and maintenance. To better understand the biomechanical effect of matrix elasticity on formation of articular cartilage analogues in vitro, this study aimed at assessing the redifferentiation capacity of primary human chondrocytes in three different hydrogel matrices of predefined matrix elasticities. The hydrogel elasticities were chosen to represent a wide range of tissue stiffness between very soft tissues with 1 kPa Young’s modulus and perichondral-space mimicking 30 kPa elasticity. In addition, the interplay of matrix elasticity and transforming growth factor beta-3 (TGF-β3) on redifferentiation of primary human articular chondrocytes was analyzed both qualitatively (viability, morphology, histology) and quantitatively (RT-qPCR, sGAG, DNA). Results show that fibrin hydrogels of 30 kPa Young’s modulus ideally guide chondrocyte redifferentiation resulting in a native-like morphology and ECM synthesis of glycosaminoglycans (sGAG) and collagen type II. This comprehensive study sheds light on the mechanobiological impact of matrix elasticity on formation and maintenance of articular cartilage and thus represents a major step towards meeting the need for advanced in vitro tissue model to study articular cartilage regeneration and degenerative disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, T., Lai, J. H., Han, L.-H., Tong, X., & Yang, F. (2014) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0531 · Cited by 70
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Hydrogels: Properties and Applications in Biomedicine
Ho, T.-C., Chang, C.-C., Chan, H.-P., Chung, T.-W., Shu, C.-W., Chuang, K.-P., Duh, T.-H., Yang, M.-H., & Tyan, Y.-C. (2022) · Molecules · doi:10.3390/molecules27092902 · Cited by 1,091
Hydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
De novo neo-hyaline-cartilage from bovine organoids in viscoelastic hydrogels
Crispim, J. F., & Ito, K. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.008 · Cited by 71
Tan, X. H., Liu, L., Mitryashkin, A., Wang, Y., & Goh, J. C. H. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00313 · Cited by 36
Metadata
- Authors
- Bachmann, B., Spitz, S., Schädl, B., Teuschl, A. H., Redl, H., Nürnberger, S., & Ertl, P.
- Venue
- Frontiers in Bioengineering and Biotechnology
- Publisher
- Frontiers Media SA
- Published
- 2020-04-30
- Volume
- 8
- Pages
- 373-373
- ISSN
- 2296-4185 (ISSN-L)
- OpenAlex
- W3020862515
- Cited by
- 105
- References
- 1
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.