Construction and Evaluation of Rodent-Specific rTMS Coils
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Rodent models of transcranial magnetic stimulation (TMS) play a crucial role in aiding the understanding of the cellular and molecular mechanisms underlying TMS induced plasticity. Rodent-specific TMS have previously been used to deliver focal stimulation at the cost of stimulus intensity (12 mT). Here we describe two novel TMS coils designed to deliver repetitive TMS (rTMS) at greater stimulation intensities whilst maintaining spatial resolution. Two circular coils (8 mm outer diameter) were constructed with either an air or pure iron-core. Peak magnetic field strength for the air and iron-cores were 90 and 120 mT, respectively, with the iron-core coil exhibiting less focality. Coil temperature and magnetic field stability for the two coils undergoing rTMS, were similar at 1 Hz but varied at 10 Hz. Finite element modeling of 10 Hz rTMS with the iron-core in a simplified rat brain model suggests a peak electric field of 85 and 12.7 V/m, within the skull and the brain, respectively. Delivering 10 Hz rTMS to the motor cortex of anaesthetized rats with the iron-core coil significantly increased motor evoked potential amplitudes immediately after stimulation (n = 4). Our results suggest these novel coils generate modest magnetic and electric fields, capable of altering cortical excitability and provide an alternative method to investigate the mechanisms underlying rTMS-induced plasticity in an experimental setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gersner, R., Kravetz, E., Feil, J., Pell, G., & Zangen, A. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.6751-10.2011 · Cited by 313 · cited 2×
“Neural Circuits 10:47. doi: 10.3389/fncir.2016.00047 Construction and Evaluation of Rodent-Specific rTMS Coils Alexander D. Tang1*, Andrea S. Lowe2,3, Andrew R. Garrett1, Robert Woodward4, William Bennett5, Alison J. Canty5, Michael I. Garry6, Mark R. Hinder6, Jeffery J. Summers6,7, Roman Gersner8,…”
BackgroundInfluentialSelf-citation
Cited by
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
“Finally, a significant body of work has addressed the issue of building practical and efficient TMS coils for small animals (for example, Rastogi et al., 2016; Tang et al., 2016b).”
Self-citationMoretti, J., & Rodger, J. (2022) · Current Research in Neurobiology · doi:10.1016/j.crneur.2022.100033 · Cited by 60
Self-citationNguyen, P. T., Makowiecki, K., Lewis, T. S., Fortune, A. J., Clutterbuck, M., Reale, L. A., Taylor, B. V., Rodger, J., Cullen, C. L., & Young, K. M. (2024) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-024-05391-0 · Cited by 21
“…was delivered as previously described [29] using a custom made 120mT circular coil designed for rodent stimulation (8 mm outer diameter, iron core) [37]. iTBS consisted of bursts of 3 pulses at 50 Hz, repeated at 5 Hz for a 2 s period (10 bursts), followed by an 8 s gap, repeated for 20 cycles…”
MethodSelf-citation
Metadata
- Authors
- Tang, A. D., Lowe, A. S., Garrett, A. R., Woodward, R., Bennett, W., Canty, A. J., Garry, M. I., Hinder, M. R., Summers, J. J., Gersner, R., Rotenberg, A., Thickbroom, G., Walton, J., & Rodger, J.
- Venue
- Frontiers in Neural Circuits
- Publisher
- Frontiers Media SA
- Published
- 2016-06-30
- Volume
- 10
- Pages
- 47-47
- ISSN
- 1662-5110 (ISSN-L)
- OpenAlex
- W2471158066
- Cited by
- 100
- References
- 1
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.