The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Classification of EEG Signals Based on Pattern Recognition Approach
Open accessAbstract
Feature extraction is an important step in the process of electroencephalogram (EEG) signal classification. The authors propose a "pattern recognition" approach that discriminates EEG signals recorded during different cognitive conditions. Wavelet based feature extraction such as, multi-resolution decompositions into detailed and approximate coefficients as well as relative wavelet energy were computed. Extracted relative wavelet energy features were normalized to zero mean and unit variance and then optimized using Fisher's discriminant ratio (FDR) and principal component analysis (PCA). A high density EEG dataset validated the proposed method (128-channels) by identifying two classifications: (1) EEG signals recorded during complex cognitive tasks using Raven's Advance Progressive Metric (RAPM) test; (2) EEG signals recorded during a baseline task (eyes open). Classifiers such as, K-nearest neighbors (KNN), Support Vector Machine (SVM), Multi-layer Perceptron (MLP), and Naïve Bayes (NB) were then employed. Outcomes yielded 99.11% accuracy via SVM classifier for coefficient approximations (A5) of low frequencies ranging from 0 to 3.90 Hz. Accuracy rates for detailed coefficients were 98.57 and 98.39% for SVM and KNN, respectively; and for detailed coefficients (D5) deriving from the sub-band range (3.90-7.81 Hz). Accuracy rates for MLP and NB classifiers were comparable at 97.11-89.63% and 91.60-81.07% for A5 and D5 coefficients, respectively. In addition, the proposed approach was also applied on public dataset for classification of two cognitive tasks and achieved comparable classification results, i.e., 93.33% accuracy with KNN. The proposed scheme yielded significantly higher classification performances using machine learning classifiers compared to extant quantitative feature extraction. These results suggest the proposed feature extraction method reliably classifies EEG signals recorded during cognitive tasks with a higher degree of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Machine learning classifiers and fMRI: A tutorial overview
Pereira, F., Mitchell, T., & Botvinick, M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.11.007 · Cited by 1,624
Performance evaluation of classification algorithms by k-fold and leave-one-out cross validation
Wong, T.-T. (2015) · Pattern Recognition · doi:10.1016/j.patcog.2015.03.009 · Cited by 1,562 · cited 1×
“…in the present work were trained and tested with EEG data and then confirmed using k-fold cross validation, which is a commonly used technique that compares (i) performances of two classification algorithms, or (ii) evaluates the performance of a single classifier on a given dataset (Wong, 2015).”
MethodThe Raven's Progressive Matrices: Change and Stability over Culture and Time
Raven, J. (2000) · Cognitive Psychology · doi:10.1006/cogp.1999.0735 · Cited by 1,560 · cited 4×
“Raven’s Advance Progressive Matric Test (Raven, 2000) is a non-verbal tool that measures levels of an individual’s intellectual ability.”
BackgroundMethodInfluentialIntelligence and neural efficiency
Neubauer, A. C., & Fink, A. (2009) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.04.001 · Cited by 878 · cited 1×
“Thepresent study utilized “Raven’s Advance Progressive Metric” (RAPM)—commonly used to measure inter-individual differences in cognitive performance—as its standard psychometric cognitive task to stimulate EEG data (Raven, 2000; Neubauer and Fink, 2009).”
Method
Cited by
A Review on Machine Learning for EEG Signal Processing in Bioengineering
Hosseini, M.-P., Hosseini, A., & Ahi, K. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2969915 · Cited by 468
Metadata
- Authors
- Amin, H. U., Mumtaz, W., Subhani, A. R., Saad, M. N. M., & Malik, A. S.
- Venue
- Frontiers in Computational Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2017-11-21
- Volume
- 11
- Pages
- 103-103
- ISSN
- 1662-5188 (ISSN-L)
- OpenAlex
- W2770341796
- Cited by
- 211
- References
- 4
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.