Machine learning approach for ambient-light-corrected parameters and the Pupil Reactivity (PuRe) score in smartphone-based pupillometry
Published version of a preprint
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Introduction: The pupillary light reflex (PLR) is the constriction of the pupil in response to light. The PLR in response to a pulse of light follows a complex waveform that can be characterized by several parameters. It is a sensitive marker of acute neurological deterioration, but is also sensitive to the background illumination in the environment in which it is measured. To detect a pathological change in the PLR, it is therefore necessary to separate the contributions of neuro-ophthalmic factors from ambient illumination. Illumination varies over several orders of magnitude and is difficult to control due to diurnal, seasonal, and location variations. Methods and results: We assessed the sensitivity of seven PLR parameters to differences in ambient light, using a smartphone-based pupillometer (AI Pupillometer, Solvemed Inc.). Nine subjects underwent 345 measurements in ambient conditions ranging from complete darkness (<5 lx) to bright lighting (≲10,000 lx). Lighting most strongly affected the initial pupil size, constriction amplitude, and velocity. Nonlinear models were fitted to find the correction function that maximally stabilized PLR parameters across different ambient light levels. Next, we demonstrated that the lighting-corrected parameters still discriminated reactive from unreactive pupils. Ten patients underwent PLR testing in an ophthalmology outpatient clinic setting following the administration of tropicamide eye drops, which rendered the pupils unreactive. The parameters corrected for lighting were combined as predictors in a machine learning model to produce a scalar value, the Pupil Reactivity (PuRe) score, which quantifies Pupil Reactivity on a scale 0–5 (0, non-reactive pupil; 0–3, abnormal/“sluggish” response; 3–5, normal/brisk response). The score discriminated unreactive pupils with 100% accuracy and was stable under changes in ambient illumination across four orders of magnitude. Discussion: This is the first time that a correction method has been proposed to effectively mitigate the confounding influence of ambient light on PLR measurements, which could improve the reliability of pupillometric parameters both in pre-hospital and inpatient care settings. In particular, the PuRe score offers a robust measure of Pupil Reactivity directly applicable to clinical practice. Importantly, the formulae behind the score are openly available for the benefit of the clinical research community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore, the recent integration of artificial intelligence and mobile-based pupillometry systems has expanded their utility; smartphone-based measurement applications and machine learning (ML) algorithms have been shown to deliver reliable assessments even under variable lighting conditions (10).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [10]
In the citing paper
“Bogucki et al. demonstrated that the Pupil Reactivity (PuRe) score, developed using smartphone-based pupillometry, provides reliable results despite variations in ambient lighting conditions (10).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [10]
In the citing paper
“Studies have demonstrated the applicability of these technologies in distinguishing sportrelated concussion (SRC) and acute ischemic-hemorrhagic stroke (10,26).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [10]
In the citing paper
“Today, smartphone-based pupillometry systems and artificial intelligence-assisted analytical techniques have shown promising results in the rapid and accurate differentiation of acute neurological conditions.”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [10]
In the citing paper
“The recently developed Pupil Reactivity (PuRe) score provides reliable assessment of pupillary reactivity despite varying lighting conditions, thereby demonstrating potential to improve consistency, particularly in emergency department settings (10).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al. (2020) · arXiv · doi:10.48550/arxiv.2010.11929 · Cited by 47,472
Research works printed but not linked: 31
- Kardon, 1995, Pupillary light reflex, Curr Opin Ophthalmol, 6, 20, 10.1097/00055735-199512000-00004 · DOI
- Ellis, 1981, The pupillary light reflex in normal subjects, Br J Ophthalmol, 65, 754, 10.1136/bjo.65.11.754 · DOI · Paper page
- Meeker, 2005, Pupil examination: validity and clinical utility of an automated pupillometer, J Neurosci Nurs, 37, 34, 10.1097/01376517-200502000-00006 · doi:10.1097/01376517-200502000-00006
- Sharma, 2016, Factors influencing the pupillary light reflex in healthy individuals, Graefe's Archiv Clin Exp Ophthalmol, 254, 1353, 10.1007/s00417-016-3311-4 · DOI · Paper page
- Ong, 2019, The effect of ambient light conditions on quantitative pupillometry, Neurocrit Care, 30, 316, 10.1007/s12028-018-0607-8 · DOI · Paper page
- Couret, 2019, The effect of ambient-light conditions on quantitative pupillometry: a history of rubber cup, Neurocrit Care, 30, 492, 10.1007/s12028-018-0664-z · doi:10.1007/s12028-018-0664-z
- Greer, 2020, Determination of brain death/death by neurologic criteria: the world brain death project, J Am Med Assoc, 324, 1078, 10.1001/jama.2020.11586 · DOI · Paper page
- Couret, 2016, Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study, Crit Care, 20, 99, 10.1186/s13054-016-1239-z · DOI · Paper page
- Aderman, 2023, Normative values for pupillary light reflex metrics among healthy service academy cadets, Milit Med, 2023, usad271, 10.1093/milmed/usad271 · doi:10.1093/milmed/usad271
- Shah, 2020, Establishing a normative database for quantitative pupillometry in the pediatric population, BMC Ophthalmol, 20, 121, 10.1186/s12886-020-01389-x · doi:10.1186/s12886-020-01389-x
- Lussier, 2019, Distributions and reference ranges for automated pupillometer values in neurocritical care patients, J Neurosci Nurs, 51, 335, 10.1097/JNN.0000000000000478 · doi:10.1097/jnn.0000000000000478
- Phillips, 2019, A systematic review assessing the current state of automated pupillometry in the NeuroICU, Neurocrit Care, 31, 142, 10.1007/s12028-018-0645-2 · doi:10.1007/s12028-018-0645-2
- Kim, 2022, Quantitative assessments of pupillary light reflexes in neurocritically ill patients, J Neurocrit Care, 15, 79, 10.18700/jnc.220085 · doi:10.18700/jnc.220085
- Boulter, 2021, The expanding role of quantitative pupillometry in the evaluation and management of traumatic brain injury, Front Neurol, 12, 685313, 10.3389/fneur.2021.685313 · doi:10.3389/fneur.2021.685313
- Bower, 2021, Quantitative pupillometry in the intensive care unit, J Intens Care Med, 36, 383, 10.1177/0885066619881124 · doi:10.1177/0885066619881124
- Chen, 2011, Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the neurological pupil index, Surg Neurol Int, 2, 82, 10.4103/2152-7806.82248 · DOI · Paper page
- Ong, 2023, Quantitative pupillometry: not a clear predictor of delayed cerebral ischemia after subarachnoid hemorrhage, Neurocritical Care, 39, 34, 10.1007/s12028-023-01709-1 · doi:10.1007/s12028-023-01709-1
- Prescott, 2022, Anisocoria and poor pupil reactivity by quantitative pupillometry in patients with intracranial pathology, Crit Care Med, 50, e143, 10.1097/CCM.0000000000005272 · DOI
- Olson, 2016, The use of automated pupillometry in critical care, Crit Care Nurs Clin N Am, 28, 101, 10.1016/j.cnc.2015.09.003 · DOI
- Ong, 2023, The prognostic potential of pupillometry in patients with acute brain injury, Lancet Neurol, 22, 876, 10.1016/S1474-4422(23)00314-9 · doi:10.1016/s1474-4422(23)00314-9
- Zafar, 2014, Automated pupillometer for monitoring the critically ill patient: a critical appraisal, J Crit Care, 29, 599, 10.1016/j.jcrc.2014.01.012 · DOI
- Leinonen, 2018, Raised intracranial pressure and brain edema, Handb Clin Neurol, 145, 25, 10.1016/B978-0-12-802395-2.00004-3 · DOI
- Changa, 2019, Management of elevated intracranial pressure: a review, Current Neurol Neurosci Rep, 19, 99, 10.1007/s11910-019-1010-3 · DOI
- Olson, 2016, Interrater reliability of pupillary assessments, Neurocrit Care, 24, 251, 10.1007/s12028-015-0182-1 · DOI
- Omburo, 2017, High variance in pupillary examination findings among postanesthesia care unit nurses, J PeriAnesth Nurs, 32, 219, 10.1016/j.jopan.2015.05.117 · DOI · Paper page
- Chougule, 2019, Light-induced pupillary responses in Alzheimer's disease, Front Neurol, 10, 360, 10.3389/fneur.2019.00360 · DOI · Paper page
- Packiasabapathy, 2021, Pupillometry in perioperative medicine: a narrative review, Can J Anesth, 68, 566, 10.1007/s12630-020-01905-z · doi:10.1007/s12630-020-01905-z
- Alexis, 2023, Assessment of altered mental status in the emergency department using quantitative pupillometry: a prospective cohort study (P7-4, Neurology, 10.1212/WNL.0000000000204165 · doi:10.1212/wnl.0000000000204165
- Fink, 2023, From pre-processing to advanced dynamic modeling of pupil data, Behav Res Methods, 23, 2098, 10.3758/s13428-023-02098-1 · DOI
- Reilly, 2023, The human task-evoked pupillary response function is linear: Implications for baseline response scaling in pupillometry, Behav Res Methods, 59, 865, 10.3758/s13428-018-1134-4 · DOI
- Sherman, 2018, Acute and chronic effects of hypobaric exposure upon the brain, 10.5772/intechopen.74231 · DOI
Cited by
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Metadata
- Authors
- Bogucki, A., John, I., Zinkiewicz, Ł., Jachura, M., Jaworski, D., Suwała, K., Chrost, H., Wlodarski, M., Kałużny, J., Campbell, D., Bakken, P., Pandya, S., Chrapkiewicz, R., & Manohar, S. G.
- Venue
- Frontiers in Neurology
- Publisher
- Frontiers Media SA
- Published
- 2024-04-09
- Volume
- 15
- ISSN
- 1664-2295
- Cited by
- 16
- References
- 2
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine learning approach for ambient-light-corrected parameters and the Pupil Reactivity (PuRe) score in smartphone-based pupillometry. https://app.cochat.ai/papers/10.3389/fneur.2024.1363190
- The paper
- Bogucki, A., John, I., Zinkiewicz, Ł., Jachura, M., Jaworski, D., Suwała, K., Chrost, H., Wlodarski, M., Kałużny, J., Campbell, D., Bakken, P., Pandya, S., Chrapkiewicz, R., & Manohar, S. G. (2024). Machine learning approach for ambient-light-corrected parameters and the Pupil Reactivity (PuRe) score in smartphone-based pupillometry. Frontiers in Neurology. https://doi.org/10.3389/fneur.2024.1363190
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.