A Self-Calibrating, Camera-Based Eye Tracker for the Recording of Rodent Eye Movements
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Much of neurophysiology and vision science relies on careful measurement of a human or animal subject's gaze direction. Video-based eye trackers have emerged as an especially popular option for gaze tracking, because they are easy to use and are completely non-invasive. However, video eye trackers typically require a calibration procedure in which the subject must look at a series of points at known gaze angles. While it is possible to rely on innate orienting behaviors for calibration in some non-human species, other species, such as rodents, do not reliably saccade to visual targets, making this form of calibration impossible. To overcome this problem, we developed a fully automated infrared video eye-tracking system that is able to quickly and accurately calibrate itself without requiring co-operation from the subject. This technique relies on the optical geometry of the cornea and uses computer-controlled motorized stages to rapidly estimate the geometry of the eye relative to the camera. The accuracy and precision of our system was carefully measured using an artificial eye, and its capability to monitor the gaze of rodents was verified by tracking spontaneous saccades and evoked oculomotor reflexes in head-fixed rats (in both cases, we obtained measurements that are consistent with those found in the literature). Overall, given its fully automated nature and its intrinsic robustness against operator errors, we believe that our eye-tracking system enhances the utility of existing approaches to gaze-tracking in rodents and represents a valid tool for rodent vision studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modulation of visual responses by behavioral state in mouse visual cortex
Niell, C. M., & Stryker, M. P. (2010) · Neuron · doi:10.1016/j.neuron.2010.01.033 · Cited by 1,483
Highly selective receptive fields in mouse visual cortex
Niell, C. M., & Stryker, M. P. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.0623-08.2008 · Cited by 1,081 · cited 2×
“However, rodents are increasingly recognized as a valuable model system for the study of various aspects of visual processing (Xu et al., 2007; Griffiths et al., 2008; Niell and Stryker, 2008, 2010; Jacobs et al., 2009; Lopez-Aranda et al., 2009; Zoccolan et al., 2009).”
Background
Cited by
Functional specialization of mouse higher visual cortical areas
Andermann, M. L., Kerlin, A. M., Roumis, D. K., Glickfeld, L. L., & Reid, R. C. (2011) · Neuron · doi:10.1016/j.neuron.2011.11.013 · Cited by 406
“In a subset of experiments (Figure S2), we analyzed eye position using custom Matlab implementation of a previously described algorithm for pupil tracking (Zoccolan et al., 2010).”
MethodInception loops discover what excites neurons most using deep predictive models
Walker, E. Y., Sinz, F. H., Cobos, E., Muhammad, T., Froudarakis, E., Fahey, P. G., Ecker, A. S., Reimer, J., Pitkow, X., & Tolias, A. S. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0517-x · Cited by 215
A method for single-neuron chronic recording from the retina in awake mice
Hong, G., Fu, T.-M., Qiao, M., Viveros, R. D., Yang, X., Zhou, T., Lee, J. M., Park, H.-G., Sanes, J. R., & Lieber, C. M. (2018) · Science · doi:10.1126/science.aas9160 · Cited by 172
“5") was placed a distance of 20 cm from both eyes of the mouse, covering an azimuth angle range of ±52°, similar to previously reported protocols (29).”
Decision-making behaviors: weighing ethology, complexity, and sensorimotor compatibility
Juavinett, A. L., Erlich, J. C., & Churchland, A. K. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.001 · Cited by 82
“Tools to automatically track such variables in head-restrained mice are increasingly available and widely implemented [85,86], and will continue to benefit from the development of unsupervised approaches.”
BackgroundCaspi, A., Roy, A., Wuyyuru, V., Rosendall, P. E., Harper, J. W., Katyal, K. D., Barry, M. P., Dagnelie, G., & Greenberg, R. J. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22377 · Cited by 47
“Eyetracking calibration without visual stimuli was done based on pupil location relative to corneal reflections of the infrared illuminators.(18) Snapshots from the eye-tracking camera showing the pupil and the six corneal reflections can be seen in Figure 1.”
MethodAsymmetric retinal direction tuning predicts optokinetic eye movements across stimulus conditions
Harris, S. C., & Dunn, F. A. (2023) · eLife · doi:10.7554/elife.81780 · Cited by 21
Metadata
- Authors
- Zoccolan, D., Graham, B. J., & Cox, D. D.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2010
- Volume
- 4
- Pages
- 193-193
- ISSN
- 1662-453X (ISSN-L)
- 1662-4548
- OpenAlex
- W2100881624
- Cited by
- 47
- References
- 2
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.