Design and Optimization of an EEG-Based Brain Machine Interface (BMI) to an Upper-Limb Exoskeleton for Stroke Survivors
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
This study demonstrates the feasibility of detecting motor intent from brain activity of chronic stroke patients using an asynchronous electroencephalography (EEG)-based brain machine interface (BMI). Intent was inferred from movement related cortical potentials (MRCPs) measured over an optimized set of EEG electrodes. Successful intent detection triggered the motion of an upper-limb exoskeleton (MAHI Exo-II), to guide movement and to encourage active user participation by providing instantaneous sensory feedback. Several BMI design features were optimized to increase system performance in the presence of single-trial variability of MRCPs in the injured brain: (1) an adaptive time window was used for extracting features during BMI calibration; (2) training data from two consecutive days were pooled for BMI calibration to increase robustness to handle the day-to-day variations typical of EEG, and (3) BMI predictions were gated by residual electromyography (EMG) activity from the impaired arm, to reduce the number of false positives. This patient-specific BMI calibration approach can accommodate a broad spectrum of stroke patients with diverse motor capabilities. Following BMI optimization on day 3, testing of the closed-loop BMI-MAHI exoskeleton, on 4th and 5th days of the study, showed consistent BMI performance with overall mean true positive rate (TPR) = 62.7 ± 21.4% on day 4 and 67.1 ± 14.6% on day 5. The overall false positive rate (FPR) across subjects was 27.74 ± 37.46% on day 4 and 27.5 ± 35.64% on day 5; however for two subjects who had residual motor function and could benefit from the EMG-gated BMI, the mean FPR was quite low (< 10%). On average, motor intent was detected -367 ± 328 ms before movement onset during closed-loop operation. These findings provide evidence that closed-loop EEG-based BMI for stroke patients can be designed and optimized to perform well across multiple days without system recalibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · cited 2×
“LIBSVM extends traditional SVM implementation and provides a probability estimate, i.e., P(y = Go | x), given a sample vector x (Chang and Lin, 2011).”
MethodDelorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“…of spatial average occurred earlier than −1.5 s (vertical black line) with respect to movement-onset, were rejected when training the classifier since these trials are most likely corrupted by artifacts. raster plots were created using EEGLAB's erpimage() function (Delorme and Makeig, 2004).”
MethodInfluentialAn introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879 · cited 1×
“By grouping the assigned probability estimate on all test trials from the 10 folds, the classifier's ROC curve was computed (Fawcett, 2006).”
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Motor recovery after stroke: a systematic review
Langhorne, P., Coupar, F., & Pollock, A. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70150-4 · Cited by 2,319 · cited 1×
“Functional restoration of arm and hand movements is a major goal of post-stroke rehabilitation therapy (Langhorne et al., 2009; Basteris et al., 2014).”
BackgroundEffects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503 · cited 2×
“There exists evidence to suggest that robotassisted therapy improves upper-limb functional assessment scores (Kwakkel et al., 2008; Klamroth-Marganska et al., 2014) and strength (Milot et al., 2013), by inducing activity-dependent cortical plasticity (Hogan et al., 2006; O'Malley et al., 2006;…”
BackgroundRobot-Assisted Therapy for Long-Term Upper-Limb Impairment after Stroke
Lo, A. C., Guarino, P. D., Richards, L. G., Haselkorn, J. K., Wittenberg, G. F., Federman, D. G., Ringer, R. J., Wagner, T. H., Krebs, H. I., Volpe, B. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0911341 · Cited by 1,397
Cited by
HS-CNN: a CNN with hybrid convolution scale for EEG motor imagery classification
Dai, G., Zhou, J., Huang, J., & Wang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab405f · Cited by 336
EEG neural correlates of goal-directed movement intention
Pereira, J., Ofner, P., Schwarz, A., Sburlea, A. I., & Müller-Putz, G. R. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.030 · Cited by 116
“…(MRCPs) and are EEG neural correlates of movement planning and execution (Birbaumer et al., 1990) which have been used for movement detection (Bhagat et al., 2016, 2014; Jochumsen et al., 2015a, 2015b, 2013; Kamavuako et al., 2015; Lew et al., 2012; López-Larraz et al., 2014; Xu et al.,…”
A systematic deep learning model selection for p300-based brain-computer interfaces
Abibullaev, B., & Zollanvari, A. (2022) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2021.3051136 · Cited by 53
Self-citationThe Emergence of Functional Ultrasound for Noninvasive Brain–Computer Interface
Zheng, H., Niu, L., Qiu, W., Liang, D., Long, X., Li, G., Liu, Z., & Meng, L. (2023) · Research · doi:10.34133/research.0200 · Cited by 27
“Moreover, varied applications based on BCIs have been developed, such as neurorehabilitation [4], neurocommunication [6], and exoskeletons [8].”
Metadata
- Authors
- Bhagat, N. A., Venkatakrishnan, A., Abibullaev, B., Artz, E. J., Yozbatiran, N., Blank, A. A., French, J., Karmonik, C., Grossman, R. G., O'Malley, M. K., Francisco, G. E., & Contreras-Vidal, J. L.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2016-03-31
- Volume
- 10
- Pages
- 122-122
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2332563861
- Cited by
- 174
- References
- 84
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.