Passive Back Support Exoskeleton Improves Range of Motion Using Flexible Beams
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
In the EU, lower back pain affects more than 40% of the working population. Mechanical loading of the lower back has been shown to be an important risk factor. Peak mechanical load can be reduced by ergonomic interventions, the use of cranes and, more recently, by the use of exoskeletons. Despite recent advances in the development of exoskeletons for industrial applications, they are not widely adopted by industry yet. Some of the challenges, which have to be overcome are a reduced range of motion, misalignment between the human anatomy and kinematics of the exoskeleton as well as discomfort. A body of research exists on how an exoskeleton can be designed to compensate for misalignment and thereby improve comfort. However, how to design an exoskeleton that achieves a similar range of motion as a human lumbar spine of up to 60° in the sagittal plane, has not been extensively investigated. We addressed this need by developing and testing a novel passive back support exoskeleton, including a mechanism comprised of flexible beams, which run in parallel to the spine, providing a large range of motion and lowering the peak torque requirements around the lumbo-sacral (L5/S1) joint. Furthermore, we ran a pilot study to test the biomechanical (N = 2) and functional (N = 3) impact on subjects while wearing the exoskeleton. The biomechanical testing was once performed with flexible beams as a back interface and once with a rigid structure. An increase of more than 25% range of motion of the trunk in the sagittal plane was observed by using the flexible beams. The pilot functional tests, which are compared to results from a previous study with the Laevo device, suggest, that the novel exoskeleton is perceived as less hindering in almost all tested tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dagenais, S., Caro, J., & Haldeman, S. (2008) · The Spine Journal · doi:10.1016/j.spinee.2007.10.005 · Cited by 2,046 · cited 1×
“Besides the health risks for the workers, these numbers also have quite severe financial implications: Cost estimates for health expenditure, caused by lower back pain range from 116e per capita in Belgium up to 209e per capita in Sweden (Dagenais et al., 2008).”
BackgroundRevised NIOSH equation for the design and evaluation of manual lifting tasks
WATERS, T. R., PUTZ-ANDERSON, V., GARG, A., & FINE, L. J. (1993) · Ergonomics · doi:10.1080/00140139308967940 · Cited by 2,042
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677 · cited 1×
“marker clusters using a probe with six markers (Cappozzo et al., 1995).”
MethodExoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Orthopedic Physical Assessment
Braddom, R. L. (1998) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199807000-00011 · Cited by 654
Wearable Robots: Biomechatronic Exoskeletons
(2008) · Wiley eBooks · doi:10.1002/9780470987667 · Cited by 517
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Measure of Man and Woman: Human Factors in Design
Tilley, A. R. (1993) · Cumulative Index of Computer Aided Architectural Design · Cited by 451
Kinematic Design to Improve Ergonomics in Human Machine Interaction
Schiele, A., & van der Helm, F. C. T. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.881565 · Cited by 386
A Musculoskeletal model for the lumbar spine
Christophy, M., Faruk Senan, N. A., Lotz, J. C., & O’Reilly, O. M. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0290-6 · Cited by 319 · cited 1×
“More complex models, consist of five separate spherical joints to model the lumbar spine (Christophy et al., 2012).”
Coenen, P., Gouttebarge, V., van der Burght, A. S. A. M., van Dieën, J. H., Frings-Dresen, M. H. W., van der Beek, A. J., & Burdorf, A. (2014) · Occupational and Environmental Medicine · doi:10.1136/oemed-2014-102346 · Cited by 318 · cited 3×
“INTRODUCTION Lower Back Pain (LBP) and shoulder pain affects more than 40% of the working population in the EU (Eurofound, 2012).”
BackgroundAbdoli-E, M., Agnew, M. J., & Stevenson, J. M. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.12.021 · Cited by 218
The use of the Visual Analogue Scale (VAS) in rehabilitation outcomes
Kersten, P., Küçükdeveci, A., & Tennant, A. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0999 · Cited by 149
Ulrey, B. L., & Fathallah, F. A. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.08.014 · Cited by 134
MACCEPA 2.0: compliant actuator used for energy efficient hopping robot Chobino1D
Vanderborght, B., Tsagarakis, N. G., Ham, R. V., Thorson, I., & Caldwell, D. G. (2011) · Autonomous Robots · doi:10.1007/s10514-011-9230-7 · Cited by 115
Self-citationAbdoli-Eramaki, M., Stevenson, J. M., Reid, S. A., & Bryant, J. T. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.006 · Cited by 109 · cited 4×
“Soft, suit like structures have a relatively long history in back support devices (Abdoli-Eramaki et al., 2007).”
BackgroundInfluentialLower Extremity Exoskeleton Reduces Back Forces in Lifting
Wehner, M. F., Rempel, D. M., & Kazerooni, H. (2009) · ASME Dynamic Systems and Control Conference (DSCC) · doi:10.1115/dscc2009-2644 · Cited by 90
Improvement and quantitative performance estimation of the back support muscle suit
Muramatsu, Y., Umehara, H., & Kobayashi, H. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610133 · Cited by 86 · cited 5×
“above mentioned ones, that accounts for this additional degree of freedom in the sagittal plane with an additional joint, is the Back Support Muscle Suit (Muramatsu et al., 2013).”
BackgroundInfluentialHow to lift a box that is too large to fit between the knees
Kingma, I., Faber, G. S., & van Dieën, J. H. (2010) · Ergonomics · doi:10.1080/00140139.2010.512983 · Cited by 78 · cited 3×
“Twowellestablished cases include: a predominant use of the hip joint with small lumbar angles, which is commonly referred to as a squat lift, or a predominant use of the lumbar joint(s) with relatively small hip angles, commonly referred to as stoop lift (Kingma et al., 2010).”
BackgroundInfluentialPredicting the Motions and Forces of Wearable Robotic Systems Using Optimal Control
Millard, M., Sreenivasa, M., & Mombaur, K. (2017) · Frontiers in Robotics and AI · doi:10.3389/frobt.2017.00041 · Cited by 50 · cited 1×
“More complex, optimization based models indicate, that torque requirements for a passive back support exoskeleton could be as low as approximately 20Nm (Millard et al., 2017).”
BackgroundDesign and Preliminary Evaluation of a Passive Spine Exoskeleton
Zhang, H., Kadrolkar, A., & Sup, F. C. (2015) · Journal of Medical Devices · doi:10.1115/1.4031798 · Cited by 48
Bilateral, Misalignment-Compensating, Full-DOF Hip Exoskeleton: Design and Kinematic Validation
Junius, K., Degelaen, M., Lefeber, N., Swinnen, E., Vanderborght, B., & Lefeber, D. (2017) · Applied Bionics and Biomechanics · doi:10.1155/2017/5813154 · Cited by 47 · cited 4×
“One that is used in a number of devices (Schiele and van der Helm, 2006; Schiele, 2009; Toxiri et al., 2016; Junius et al., 2017a), is the introduction of additional degrees of freedom (See Figure 2D).”
BackgroundInfluentialSelf-citationErgonomics of exoskeletons: Subjective performance metrics
Schiele, A. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354029 · Cited by 39
A novel self-aligning mechanism to decouple force and torques for a planar exoskeleton joint
Schorsch, J. F., Keemink, A. Q. L., Stienen, A. H. A., van der Helm, F. C. T., & Abbink, D. A. (2014) · Mechanical sciences · doi:10.5194/ms-5-29-2014 · Cited by 29
Metabolic Effects Induced by a Kinematically Compatible Hip Exoskeleton During STS
Junius, K., Lefeber, N., Swinnen, E., Vanderborght, B., & Lefeber, D. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2754922 · Cited by 24
Self-citationTowards low back support with a passive biomimetic exo-spine
Näf, M. B., Rijcke, L. D., Rodriguez‐Guerrero, C., Millard, M., Vanderborght, B., & Lefeber, D. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009407 · Cited by 14
Self-citationKersten, P., Küçükdeveci, A. A., & Tennant, A. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-1044 · Cited by 7 · cited 1×
“This allows to more accurately distinguish between participants opinion compared to numeric scales (Kersten et al., 2012).”
Background
Metadata
- Authors
- Näf, M. B., Koopman, A. S., Baltrusch, S., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D.
- Venue
- Frontiers in Robotics and AI
- Publisher
- Frontiers Media SA
- Published
- 2018-06-21
- Volume
- 5
- Pages
- 72-72
- ISSN
- 2296-9144 (ISSN-L)
- OpenAlex
- W2807119323
- Cited by
- 207
- References
- 27
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.