Comprehensive Review on Climate Control and Cooling Systems in Greenhouses under Hot and Arid Conditions
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
This work is motivated by the difficulty of cultivating crops in horticulture greenhouses under hot and arid climate conditions. The main challenge is to provide a suitable greenhouse indoor environment, with sufficiently low costs and low environmental impacts. The climate control inside the greenhouse constitutes an efficient methodology for maintaining a satisfactory environment that fulfills the requirements of high-yield crops and reduced energy and water resource consumption. In hot climates, the cooling systems, which are assisted by an effective control technique, constitute a suitable path for maintaining an appropriate climate inside the greenhouse, where the required temperature and humidity distribution is maintained. Nevertheless, most of the commonly used systems are either highly energy or water consuming. Hence, the main objective of this work is to provide a detailed review of the research studies that have been carried out during the last few years, with a specific focus on the technologies that allow for the enhancement of the system effectiveness under hot and arid conditions, and that decrease the energy and water consumption. Climate control processes in the greenhouse by means of manual and smart control systems are investigated first. Subsequently, the different cooling technologies that provide the required ranges of temperature and humidity inside the greenhouse are detailed, namely, the systems using heat exchangers, ventilation, evaporation, and desiccants. Finally, the recommended energy-efficient approaches of the desiccant dehumidification systems for greenhouse farming are pointed out, and the future trends in cooling systems, which include water recovery using the method of combined evaporation–condensation, as well as the opportunities for further research and development, are identified as a contribution to future research work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MORE EFFICIENT PLANTS: A Consequence of Rising Atmospheric CO2?
Drake, B. G., Gonzàlez-Meler, M. A., & Long, S. P. (1997) · Annual Review of Plant Physiology and Plant Molecular Biology · doi:10.1146/annurev.arplant.48.1.609 · Cited by 1,925 · cited 2×
“[37] proved, through 60 experiments that were performed under a CO2 enrichment of around 700 μ ol ol−1, that the increase in the photosynthesis of plants reaches 58%, compared to plants under ambient conditions.”
BackgroundDesiccant cooling air conditioning: a review
DAOU, K., WANG, R., & XIA, Z. (2006) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2004.09.010 · Cited by 491
The cooling potential of earth–air heat exchangers for domestic buildings in a desert climate
Al-ajmi, F. F., Loveday, D. L., & Hanby, V. I. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.01.027 · Cited by 361
Advanced applications of solar energy in agricultural greenhouses
Hassanien, R. H. E., Li, M., & Dong Lin, W. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.095 · Cited by 360
Does Enhanced Photosynthesis Enhance Growth? Lessons Learned from CO2 Enrichment Studies
Kirschbaum, M. U. F. (2011) · Plant Physiology · doi:10.1104/pp.110.166819 · Cited by 343
Gorjian, S., Calise, F., Kant, K., Ahamed, M. S., Copertaro, B., Najafi, G., Zhang, X., Aghaei, M., & Shamshiri, R. R. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.124807 · Cited by 320 · cited 7×
“CSCs are usually mounted with solar tracking systems to collect the maxim m radiation, and they are coupled to solar cooling processes, particularly in hot desert locations r rural areas, where electrification is difficult and expensive, and where solar resources are abu d nt [8].”
BackgroundInfluentialSurvey of cooling technologies for worldwide agricultural greenhouse applications
Sethi, V. P., & Sharma, S. K. (2007) · Solar Energy · doi:10.1016/j.solener.2007.03.004 · Cited by 288 · cited 3×
“Whitewashing is, therefore, a passive and low-cost shading technique that reduces the indoor temperature, the VPD, and the light supply [62].”
BackgroundCossu, M., Murgia, L., Ledda, L., Deligios, P. A., Sirigu, A., Chessa, F., & Pazzona, A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.07.070 · Cited by 287
An overview of solid desiccant dehumidification and air conditioning systems
Sultan, M., El-Sharkawy, I. I., Miyazaki, T., Saha, B. B., & Koyama, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.02.038 · Cited by 271
A technical review on use of liquid-desiccant dehumidification for air-conditioning application
Mei, L., & Dai, Y. J. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2006.10.006 · Cited by 265
Review: CO2 enrichment in greenhouses. Crop responses
Mortensen, L. M. (1987) · Scientia Horticulturae · doi:10.1016/0304-4238(87)90028-8 · Cited by 255 · cited 4×
“Kirschbaum [35] states that, under elevated CO2 concentrations, the photosynthetic rate increase can exceed 50%, when compared to plants grown under normal CO2 concentrations.”
BackgroundInfluentialChoab, N., Allouhi, A., El Maakoul, A., Kousksou, T., Saadeddine, S., & Jamil, A. (2019) · Solar Energy · doi:10.1016/j.solener.2019.08.042 · Cited by 253 · cited 2×
“[51] and Sethi [52], independently of the considered location, the Quonset form corresponds to the minimal values of the temperature and solar collection, as opposed to the uneven-span shape, which allows for maximum solar capture, as well as high heat records.”
BackgroundSethi, V. P. (2009) · Solar Energy · doi:10.1016/j.solener.2008.05.018 · Cited by 212 · cited 3×
“[51] and Sethi [52], independently of the considered location, the Quonset form corresponds to the minimal values of the temperature and solar collection, as opposed to the uneven-span shape, which allows for maximum solar capture, as well as high heat records.”
BackgroundInfluence of Covering Material and Shading on the Spectral Distribution of Light in Greenhouses
Kittas, C., Baille, A., & Giaglaras, P. (1999) · Journal of Agricultural Engineering Research · doi:10.1006/jaer.1999.0420 · Cited by 190 · cited 1×
“For hot climates, white painted roofs that are alternatively combined with external black shading nets, or internal aluminized screens, can guarantee the necessary shading [59].”
BackgroundDesign challenges of agricultural greenhouses in hot and arid environments – A review
Ghani, S. A., Bakochristou, F., ElBialy, E. M. A. A., Gamaledin, S. M. A., Rashwan, M., Abdelhalim, A. M., & Ismail, S. M. (2018) · Engineering in Agriculture Environment and Food · doi:10.1016/j.eaef.2018.09.004 · Cited by 179 · cited 3×
“The water evaporation through the wet pad material leads to a decrease in the temperature, and to the humidification of the air inside the greenhouse [64].”
BackgroundPerformance of a concentrated photovoltaic energy system with static linear Fresnel lenses
Sonneveld, P. J., Swinkels, G. L. A. M., van Tuijl, B. A. J., Janssen, H. J. J., Campen, J. B., & Bot, G. P. A. (2011) · Solar Energy · doi:10.1016/j.solener.2010.12.001 · Cited by 173 · cited 4×
“(a) The PV modules of the system; (b) the linear Fresnel collectors of the system; (c) the Fresnel greenhouse (The Netherlands).”
BackgroundMethodInfluentialSolar greenhouse an option for renewable and sustainable farming
Panwar, N. L., Kaushik, S. C., & Kothari, S. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.030 · Cited by 166
Vadiee, A., & Martin, V. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.04.022 · Cited by 165 · cited 3×
“Furthermore, given the close relationship between the ventilation rate and the CO2 concentration inside the greenhouse, it is strongly recommended that these two parameters should be controlled simultaneously [30].”
BackgroundInfluentialGanguly, A., -, D. K. M., & Ghosh, S. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.06.012 · Cited by 163 · cited 4×
“[90], they proved that the cooling solar plant that was tested in India, which combined a fan and pad evaporative system and PV panels, provided the coolness required for a 90 m2 greenhouse.”
BackgroundInfluentialOptimal control of greenhouse climate using minimal energy and grower defined bounds
van Beveren, P. J. M., Bontsema, J., van Straten, G., & van Henten, E. J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.09.012 · Cited by 159 · cited 1×
“[50] found that by using the optimal control method, the cooling energy consumption and the CO2 injection could be reduced by up 15% and 10%, respectively.”
MethodRecent progress in liquid desiccant dehumidification and air-conditioning: A review
Chen, X., Riffat, S., Bai, H., Zheng, X., & Reay, D. (2019) · Energy and Built Environment · doi:10.1016/j.enbenv.2019.09.001 · Cited by 149
Comprehensive review on dehumidification strategies for agricultural greenhouse applications
Amani, M., Foroushani, S., Sultan, M. A., & Bahrami, M. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115979 · Cited by 146 · cited 8×
“[5] found that the optimal relative humidity inside the greenhouse should range between 60 and 80%.”
BackgroundInfluentialRecent advancements in liquid desiccant dehumidification technology
Yin, Y., Qian, J., & Zhang, X. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.11.021 · Cited by 143
Renewable energy for liquid desiccants air conditioning system: A review
Fekadu, G., & Subudhi, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.016 · Cited by 142
Methodologies of control strategies for improving energy efficiency in agricultural greenhouses
Zhang, S., Guo, Y., Zhao, H., Wang, Y., Chow, D., & Fang, Y. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.122695 · Cited by 137 · cited 2×
“There are different types of control systems (manual, automatic, or intelligent control), where the greenhouse is equipped with Internet data monitoring [47,48].”
BackgroundXu, J., Li, Y., Wang, R. Z., Liu, W., & Zhou, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.10.061 · Cited by 132 · cited 1×
“Fan and pad systems Shanghai [93] Energy saving and easily adjustable Not sufficient in humid climates, and it is necessary to add shading Decrease in temperature to 27–29 ◦C”
BackgroundDesiccant cooling systems: a review
Sahlot, M., & Riffat, S. B. (2016) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/ctv032 · Cited by 129
Protected Cropping in Warm Climates: A Review of Humidity Control and Cooling Methods
Rabbi, B., Chen, Z., & Sethuvenkatraman, S. (2019) · Energies · doi:10.3390/en12142737 · Cited by 129
A solar cooling system for greenhouse food production in hot climates
Davies, P. A. (2005) · Solar Energy · doi:10.1016/j.solener.2005.02.001 · Cited by 122 · cited 3×
“Nonetheless, the traditional cooling processes, which involve natural ventilation and passive cooling techniques, were difficult to control, and no ideal climate conditions were guaranteed for the crops, which prohibited the cultivation of many crops, especially those that were not resistant to the high levels of temp…”
BackgroundRecent developments in solar assisted liquid desiccant evaporative cooling technology—A review
Büker, M. S., & Riffat, S. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.03.020 · Cited by 119
Dehumidification of Greenhouses at Northern Latitudes
Campen, J. B., Bot, G. P. A., & de Zwart, H. F. (2003) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2003.08.008 · Cited by 102 · cited 1×
“[80] investigated the effect of using the exchanger in the greenhouse on economic incomes.”
BackgroundEffect of variable CO2 enrichment on greenhouse production in mild winter climates
Sánchez-Guerrero, M. C., Lorenzo, P., Medrano, E., et al. (2005) · Agricultural and Forest Meteorology · doi:10.1016/j.agrformet.2005.07.014 · Cited by 98 · cited 1×
“The mean daytime values averaged between 400 and 500 μmol mol−1, while, in the nonenriched greenhouse, they ranged between 285 and 300 μmol mol−1 [43,44].”
BackgroundSultan, M. A., Miyazaki, T., Saha, B. B., & Koyama, S. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.09.015 · Cited by 96 · cited 3×
“Normal and ideal greenhouse growth zones according to vapor pressure deficit levels [13].”
BackgroundSolar energy storing rock-bed to heat an agricultural greenhouse
Gourdo, L., Fatnassi, H., Tiskatine, R., Wifaya, A., Demrati, H., Aharoune, A., & Bouirden, L. (2018) · Energy · doi:10.1016/j.energy.2018.12.036 · Cited by 96
El-Maghlany, W. M., Teamah, M. A., & Tanaka, H. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.08.066 · Cited by 88
Waller, R., Kaçıra, M., Magadley, E., Teitel, M., & Yehia, I. (2021) · Agronomy · doi:10.3390/agronomy11061152 · Cited by 84
Rosati, A. (2003) · Annals of Botany · doi:10.1093/aob/mcg094 · Cited by 83
An experimental study of a forced flow solar collector/regenerator using liquid desiccant
Alizadeh, S., & Saman, W. Y. (2002) · Solar Energy · doi:10.1016/s0038-092x(02)00116-0 · Cited by 79
Soussi, M., Balghouthi, M., & Guizani, A. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.08.033 · Cited by 75 · cited 2×
“However, the adoption of solar collectors to generate high temperatures and to operate the system efficiently, particularly for agriculture use, is often constrained by economic and technical barriers [79,88,89].”
BackgroundSelf-citationZaragoza, G., Buchholz, M., Jochum, P., & Pérez-Parra, J. J. (2007) · Desalination · doi:10.1016/j.desal.2006.03.599 · Cited by 73
Self-citationNederhoff, E. M. (1994) · doi:10.18174/206000 · Cited by 72 · cited 1×
“Several previous studies have quantified the CO2 amount to supply in greenhouses, and they have proven that the economic-based optimal CO2 concentration for healthy crop growth ranges between 700 and 900 μmol mol−1, depending on the plant species [34,35,38,39].”
BackgroundPhotovoltaic Greenhouses: Comparison of Optical and Thermal Behaviour for Energy Savings
Carlini, M., Honorati, T., & Castellucci, S. (2012) · Mathematical Problems in Engineering · doi:10.1155/2012/743764 · Cited by 72
A comprehensive review of solar‐driven desalination technologies for off‐grid greenhouses
Shekarchi, N., & Shahnia, F. (2018) · International Journal of Energy Research · doi:10.1002/er.4268 · Cited by 70
Boughanmi, H., Lazaar, M., Bouadila, S., & Farhat, A. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.004 · Cited by 59
Greenhouse heating and cooling using aquifer water
Sethi, V. P., & Sharma, S. K. (2006) · Energy · doi:10.1016/j.energy.2006.10.022 · Cited by 54 · cited 1×
“For instance, in India, Sethi and Sharma [62,81] performed an experiment on a cooling and heating system using the aquifer water at 24 ◦C as the heat transfer fluid in the air-to-liquid heat exchanger to ensure the greenhouse heating on winter nights and cooling during summer days.”
BackgroundCooling Efficiency of Fogging Systems for Greenhouses
Abdel-Ghany, A. M., & Kozai, T. (2006) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2006.02.008 · Cited by 52 · cited 3×
“, Abdel-Ghany, and Kozai [33,107] compared three fogging cycles, with fixed fogging rates of 10 g/s, and fixed fogging spans of 30, 60, and 90 s, which were separated with time intervals of 90, 180, and 270 s, respectively.”
BackgroundA Review of Ventilation and Cooling Technologies in Agricultural Greenhouse Application
Ganguly, A., & Ghosh, S. (2011) · Iranica Journal of Energy and Environment · Cited by 49
Flores-Velázquez, J., Montero, J. I., Baeza, E. J., & López, J. C. (2014) · International journal of agricultural and biological engineering · doi:10.25165/ijabe.v7i1.887 · Cited by 43 · cited 1×
“[78], maintaining a comfortable climate inside the greenhouse is induced by combining the roof opening and the ventilators, which is better than using forced ventilators only.”
BackgroundStanghellini, C., Dai, J., & Kempkes, F. L. K. (2011) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2011.08.002 · Cited by 42 · cited 4×
“As a result, the air temperature inside the greenhouse is lowered by 5 ◦C, and the energy requirements for cooling are reduced by 8% [66,67].”
BackgroundInfluentialGreenhouse climate control in mediterranean greenhouses
Kittas, C., Katsoulas, N., & Bartzanas, T. (2012) · Cited by 42
Crop based climate regimes for energy saving in greenhouse cultivation
Körner, O. (2003) · doi:10.18174/27517 · Cited by 36
Double closed-loop optimal control of greenhouse cultivation
Xu, D., Du, S., & van Willigenburg, L. G. (2019) · Control Engineering Practice · doi:10.1016/j.conengprac.2019.01.010 · Cited by 33
Ghosh, A., & Ganguly, A. (2017) · Solar Energy · doi:10.1016/j.solener.2017.10.030 · Cited by 33
Photosynthetically Active Radiation: Measurement and Modeling
Mõttus, M., Sulev, M., Baret, F., Lopez-Lozano, R., & Reinart, A. (2013) · Springer eBooks · doi:10.1007/978-1-4614-5806-7_451 · Cited by 32
Effects of Various Radiant Sources on Plant Growth (Part 1)
Tazawa, S. (1999) · Japan Agricultural Research Quarterly JARQ · Cited by 31
Micro Climate Control in Greenhouse
Tiwari, D., Singh, V. K., & Reddy, A. R. G. (2017) · International Journal of Current Microbiology and Applied Sciences · doi:10.20546/ijcmas.2017.603.199 · Cited by 28 · cited 2×
“[74], maintaining a suitable rate of ventilation is also essential to avoiding the inequitable CO2 distribution, and to equalizing the inside greenhouse temperature to the outside temperature.”
BackgroundMaslak, K., & Nimmermark, S. (2017) · Agricultural and Food Science · doi:10.23986/afsci.58936 · Cited by 23 · cited 2×
“For instance, in Sweden and Spain, the energy consumption designed for greenhouse dehumidification via natural ventilation is estimated to be between 20 and 30% of the total energy consumption [5,71,73].”
BackgroundMethodMethodic design of a measurement and control system for climate control in horticulture
Speetjens, S. L., Janssen, H. J. J., Straten, G. V., et al. (2008) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2008.04.010 · Cited by 20
A hybrid neuro-fuzzy approach for greenhouse climate modeling
Yousefi, M. R., Hasanzadeh, S., Mirinejad, H., & Ghasemian, M. (2010) · IEEE International Conference on Intelligent Systems · doi:10.1109/is.2010.5548375 · Cited by 19 · cited 1×
“There are different types of control systems (manual, automatic, or intelligent control), where the greenhouse is equipped with Internet data monitoring [47,48].”
BackgroundMultivariable greenhouse climate control using dynamic decoupling controllers
Paraforos, D. S., & Griepentrog, H. W. (2013) · IFAC Proceedings Volumes · doi:10.3182/20130828-2-sf-3019.00064 · Cited by 16 · cited 1×
“Detailed studies have been carried out to investigate the coupling characteristics between the environmental parameters, and they show that, in order to enhance the accuracy of the control strategy for low-energy greenhouses, it is necessary to study the multiparameter coupling [47,49].”
BackgroundGreenhouse Cooling Systems and Models for Arid Climate
du Plessis, E., Workneh, T. S., & Laing, M. D. (2015) · Sustainable agriculture reviews · doi:10.1007/978-3-319-21629-4_6 · Cited by 15 · cited 1×
“[64] confirm that the evaporative cooling coupled with ven ilation devices (fans, roof openings) is more efficient for climate control in greenhouse in hot climates [91].”
BackgroundRafique, M. M., Rehman, S., Alhems, L. M., & Shakir, M. A. (2017) · Energies · doi:10.3390/en11010072 · Cited by 15 · cited 1×
“[95] report that the use of only an indirect evaporative cooler in hot and humid climates is not sufficient, and that the use of only a direct evaporative cooler is not economical.”
BackgroundWang, F. L., Wang, H., & Wang, G. (2007) · Photosynthetica · doi:10.1007/s11099-007-0009-1 · Cited by 11
Solar Powered Dehumidification Systems Using Desert Evaporative Coolers: Review
Kassem, T. K., Alosaimy, A. S., Hamed, A. M., & Fazian, M. (2013) · Cited by 11
Effect of Greenhouse Cooling Methods on the Growth and Yield of Tomato in a Mediterranean Climate
Boyacı, S., & Akyüz, A. (2018) · International journal of Horticulture Agriculture and Food science · doi:10.22161/ijhaf.2.6.1 · Cited by 8
Cited by
Adesanya, M. A., Obasekore, H., Rabiu, A., Na, W.-H., Ogunlowo, Q. O., Akpenpuun, T. D., Kim, M.-H., Kim, H.-T., Kang, B.-Y., & Lee, H.-W. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124126 · Cited by 72
Valuation of Climate Performance of a Low-Tech Greenhouse in Costa Rica
Rojas-Rishor, A., Flores-Velazquez, J., Villagran, E., & Aguilar-Rodríguez, C. E. (2022) · Processes · doi:10.3390/pr10040693 · Cited by 9
Metadata
- Authors
- Soussi, M., Chaibi, M. T., Buchholz, M., & Saghrouni, Z.
- Venue
- Agronomy
- Publisher
- MDPI AG
- Published
- 2022-03-03
- Volume
- 12
- Issue
- 3
- Pages
- 626
- ISSN
- 2073-4395 (ISSN-L)
- OpenAlex
- W4214805889
- Cited by
- 164
- References
- 65
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.