A Review on Upper Limb Rehabilitation Robots
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Rehabilitation is the process of treating post-stroke consequences. Impaired limbs are considered the common outcomes of stroke, which require a professional therapist to rehabilitate the impaired limbs and restore fully or partially its function. Due to the shortage in the number of therapists and other considerations, researchers have been working on developing robots that have the ability to perform the rehabilitation process. During the last two decades, different robots were invented to help in rehabilitation procedures. This paper explains the types of rehabilitation treatments and robot classifications. In addition, a few examples of well-known rehabilitation robots will be explained in terms of their efficiency and controlling mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 3×
“[38] MIME Assistive >6 months 27 24 sessions 8 weeks 1 h/workday the reach ability and the proximal arm strength were largely improved”
BackgroundInfluentialAdvances and challenges in stroke rehabilitation
Stinear, C. M., Lang, C. E., Zeiler, S., & Byblow, W. D. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30415-6 · Cited by 792 · cited 1×
“However, the availability of therapists, the duration of the therapeutic session and the cost of rehabilitation tools are all considered as factors that affect both the therapist and the patients [5].”
BackgroundBi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418 · cited 1×
“An electromyograph (EMG) signal extracted from the muscles fibers is used to estimate the required torque for each specific movement [77].”
MethodNEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
A paradigm shift for rehabilitation robotics
Krebs, H., Dipietro, L., Levy-Tzedek, S., Fasoli, S., Rykman-Berland, A., Zipse, J., Fawcett, J., Stein, J., Poizner, H., Lo, A., et al. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.919498 · Cited by 162
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159 · cited 3×
“The neuro-fuzzy method is commonly used in robots that are dedicated for improving the life quality of elderly and disabled people [69,70].”
BackgroundMethod
Metadata
- Authors
- Qassim, H. M., & Wan Hasan, W. Z.
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2020-10-06
- Volume
- 10
- Issue
- 19
- Pages
- 6976
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W3092608441
- Cited by
- 199
- References
- 6
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.