CoChat

Global Study of Human Heart Rhythm Synchronization with the Earth’s Time Varying Magnetic Field

Open access

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Abstract

Changes in geomagnetic conditions have been shown to affect the rhythms produced by the brain and heart and that human autonomic nervous system activity reflected in heart rate variability (HRV) over longer time periods can synchronize to changes in the amplitude of resonant frequencies produced by geomagnetic field-line and Schumann resonances. During a 15-day period, 104 participants located in California, Lithuania, Saudi Arabia, New Zealand, and England underwent continuous ambulatory HRV monitoring. The local time varying magnetic field (LMF) intensity was obtained using a time synchronized and calibrated network of magnetometers located at five monitoring sites in the same geographical locations as the participant groups. This paper focuses on the results of an experiment conducted within the larger study where all of the participants simultaneously did a heart-focused meditation called a Heart Lock-In (HLI) for a 15-min period. The participant’s level of HRV coherence and HRV synchronization to each other before, during and after the HLI and the synchronization between participants’ HRV and local time varying magnetic field power during each 24-h period were computed for each participant and group with near-optimal chaotic attractor embedding techniques. In analysis of the participants HRV coherence before, during and after the HLI, most of the groups showed significantly increased coherence during the HLI period. The pairwise heart rhythm synchronization between participants’ in each group was assessed by determining the Euclidean distance of the optimal time lag vectors of each participant to all other participants in their group. The group member’s heart rhythms were significantly more synchronized with each other during the HLI period in all the groups. The participants’ daily LMF-HRV-synchronization was calculated for each day over an 11-day period, which provided a 5-day period before, the day of and 5-days after the HLI day. The only day where all the groups HRV was positively correlated with the LMF was on the day of the HLI and the synchronization between the HRV and LMF for all the groups was significantly higher than most of the other days.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app11072935

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The original Di (blue line) and smoothed ̂ Di (red line) discrete derivative of the difference between standard deviations of filtered and non-filtered data. The degree of tolerance used in this study was set to # = 0.01 (black line). Thus, the optimal size of the filtering data window was selected as the maximal data window satisfying ̂ Di > # . It can be observed from this figure that the optimal length filtering data window corresponding to such criteria is 36,000 elements, i.e., 10 h of local magnetic field spectral power data.
Figure 1 The original Di (blue line) and smoothed ̂ Di (red line) discrete derivative of the difference between standard deviations of filtered and non-filtered data. The degree of tolerance used in this study was set to # = 0.01 (black line). Thus, the optimal size of the filtering data window was selected as the maximal data window satisfying ̂ Di > # . It can be observed from this figure that the optimal length filtering data window corresponding to such criteria is 36,000 elements, i.e., 10 h of local magnetic field spectral power data.CC-BY · From the PDF
Figure 2 Mean LMF-HRV-correlations by Day and group (Abbreviations CA, LT, NZ, SA and UK correspond to California, Lithuania, New Zealand, Saudi Arabia and United Kingdom, respectively). Note that the only day of study period where all the groups' HRV was positively correlated with the LMF was on the day 6, which was the day of the HLI and the correlations between the HRV and LMF for all the groups were substantially higher on that day.
Figure 2 Mean LMF-HRV-correlations by Day and group (Abbreviations CA, LT, NZ, SA and UK correspond to California, Lithuania, New Zealand, Saudi Arabia and United Kingdom, respectively). Note that the only day of study period where all the groups' HRV was positively correlated with the LMF was on the day 6, which was the day of the HLI and the correlations between the HRV and LMF for all the groups were substantially higher on that day.CC-BY · From the PDF
Figure 3 Mean LMF-HRV-correlation by Day and group.The day with the black color indicates day 6 which is the day all the groups did the 15-min Heart Lock-In at the same time. Pairwise significance is noted by Day# labels above each bar. It can be seen, for example, that in the Lithuanian group, day 6 (HLI day) was significantly different from all other days in the study period. Day 11 was different from three of the other days (2, 6 and 8), etc.
Figure 3 Mean LMF-HRV-correlation by Day and group.The day with the black color indicates day 6 which is the day all the groups did the 15-min Heart Lock-In at the same time. Pairwise significance is noted by Day# labels above each bar. It can be seen, for example, that in the Lithuanian group, day 6 (HLI day) was significantly different from all other days in the study period. Day 11 was different from three of the other days (2, 6 and 8), etc.CC-BY · From the PDF
Figure 4 The results of a repeated measures (within-subjects) ANOVA test assessing differences in the coherence score for all five groups during 15-min periods before (T1), during (T2) and after (T3) using the Heart lock-In technique (* corresponds to p < 0.05, ** corresponds to p < 0.001). Note that a coherence score below one is considered as low coherence, scores between one and two as medium, and scores above two as high levels of coherence. It can be seen, for example, that California's and New Zealand's group members' HRV coherence was significantly higher during the HLI period than before and after the HLI period, etc.
Figure 4 The results of a repeated measures (within-subjects) ANOVA test assessing differences in the coherence score for all five groups during 15-min periods before (T1), during (T2) and after (T3) using the Heart lock-In technique (* corresponds to p < 0.05, ** corresponds to p < 0.001). Note that a coherence score below one is considered as low coherence, scores between one and two as medium, and scores above two as high levels of coherence. It can be seen, for example, that California's and New Zealand's group members' HRV coherence was significantly higher during the HLI period than before and after the HLI period, etc.CC-BY · From the PDF
Image 5
CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Image 7
CC-BY · From the PDF
Image 8
CC-BY · From the PDF
Image 9
CC-BY · From the PDF
Figure A1. The results of the analysis of the LMF-HRV-synchronization for California. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that almost all of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF, and the highest LMF-HRV-synchronization values were obtained during the day of the Heart Lock-In.
Figure A1. The results of the analysis of the LMF-HRV-synchronization for California. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that almost all of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF, and the highest LMF-HRV-synchronization values were obtained during the day of the Heart Lock-In.CC-BY · From the PDF
Figure A2. The results of the analysis of the LMF-HRV-synchronization for Lithuania. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that almost all of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF, and the highest LMF-HRV-synchronization values were obtained during the day of the Heart Lock-In.
Figure A2. The results of the analysis of the LMF-HRV-synchronization for Lithuania. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that almost all of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF, and the highest LMF-HRV-synchronization values were obtained during the day of the Heart Lock-In.CC-BY · From the PDF
Figure A3. The results of the analysis of the LMF-HRV-synchronization for New Zealand. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that for almost all of the participants' the highest positive LMF-HRV-synchronization values were obtained during the day of the Heart Lock-In.
Figure A3. The results of the analysis of the LMF-HRV-synchronization for New Zealand. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that for almost all of the participants' the highest positive LMF-HRV-synchronization values were obtained during the day of the Heart Lock-In.CC-BY · From the PDF
Figure A4. The results of the analysis of the LMF-HRV-synchronization for Saudi Arabia. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that most of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF on the day of the Heart Lock-In.
Figure A4. The results of the analysis of the LMF-HRV-synchronization for Saudi Arabia. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that most of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF on the day of the Heart Lock-In.CC-BY · From the PDF
Figure A5. The results of the analysis of the LMF-HRV-synchronization for UK. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that most of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF on the day of the Heart Lock-In.
Figure A5. The results of the analysis of the LMF-HRV-synchronization for UK. Each part of the figure displays participants' LMF-HRV-synchronization for the indicated day. Plot (e) corresponds to the day of the Heart Lock-In. Note that most of the participants' HRV signals shifted to being positively correlated (synchronized) with LMF on the day of the Heart Lock-In.CC-BY · From the PDF
Figure A6. Pairwise synchronization for California's group. For the majority of participants (10 out of 11) the mean Euclidean distance during the HLI was smaller than before the Heart Lock-In. This means those individuals were more coherent with the group during the Heart Lock-In than they were before. The mean distance after the HLI is bigger (for the majority of participants) than before the application of the technique.
Figure A6. Pairwise synchronization for California's group. For the majority of participants (10 out of 11) the mean Euclidean distance during the HLI was smaller than before the Heart Lock-In. This means those individuals were more coherent with the group during the Heart Lock-In than they were before. The mean distance after the HLI is bigger (for the majority of participants) than before the application of the technique.CC-BY · From the PDF
Figure A7. Pairwise synchronization for New Zealand's group. For the majority of participants (18 out of 19) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that those participants were more coherent with the group during the HLI than they were before. The mean distance after the HLI is also smaller (for the majority of participants) than before the Heart Lock-In.
Figure A7. Pairwise synchronization for New Zealand's group. For the majority of participants (18 out of 19) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that those participants were more coherent with the group during the HLI than they were before. The mean distance after the HLI is also smaller (for the majority of participants) than before the Heart Lock-In.CC-BY · From the PDF
Figure A8. Pairwise synchronization for United Kingdom's group. For the majority of participants (7 out of 8) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that the participants were more coherent with the group during the HLI than they were before it. The mean distance after the Heart Lock-In procedure is smaller than before the Heart Lock-In for four out of the eight participants.
Figure A8. Pairwise synchronization for United Kingdom's group. For the majority of participants (7 out of 8) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that the participants were more coherent with the group during the HLI than they were before it. The mean distance after the Heart Lock-In procedure is smaller than before the Heart Lock-In for four out of the eight participants.CC-BY · From the PDF
Figure A9. Pairwise synchronization for Saudi Arabia's group. For the majority of participants (10 out of 11) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that the participants were more coherent with the group during the HLI than they were before it. The mean distance after the HLI is smaller than before the Heart Lock-In for 7 out of 11 participants.
Figure A9. Pairwise synchronization for Saudi Arabia's group. For the majority of participants (10 out of 11) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that the participants were more coherent with the group during the HLI than they were before it. The mean distance after the HLI is smaller than before the Heart Lock-In for 7 out of 11 participants.CC-BY · From the PDF
Figure A10. Pairwise synchronization for Lithuania's group. For the majority of participants (11 out of 16) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that those participants were more coherent with the group during the HLI than they were before it. The mean distance after the HLI is larger (for all participants) than before the HLI. Three participants who were outliers and extremely far away from others during the HLI were removed from the analysis.
Figure A10. Pairwise synchronization for Lithuania's group. For the majority of participants (11 out of 16) the mean Euclidean distance during the HLI was smaller than before the HLI, indicating that those participants were more coherent with the group during the HLI than they were before it. The mean distance after the HLI is larger (for all participants) than before the HLI. Three participants who were outliers and extremely far away from others during the HLI were removed from the analysis.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Research works printed but not linked: 2

  1. Hamer, 1965, Biological entrainment of the human brain by low frequency radiation, Northrop Space Labs, 36, 65
  2. Morris, 2010, Achieving collective coherence: Group effects on heart rate variability, coherence and heart rhythm synchronization, Altern Ther Health Med, 16, 62

Cited by

See all 28

Metadata

Authors
Timofejeva, I., McCraty, R., Atkinson, M., Alabdulgader, A. A., Vainoras, A., Landauskas, M., Šiaučiūnaitė, V., & Ragulskis, M.
Affiliations
  • Kaunas University of Technology (LT)
  • HeartMath Institute (US)
  • Research and Scientific Bio-Computing, Prince Sultan Cardiac Center, Alhasa, Hofuf 31982, Saudi Arabia
  • Lithuanian University of Health Sciences (LT)
Corresponding author
Timofejeva, Inga
Venue
Applied Sciences
Publisher
MDPI AG
Published
2021-03-25
Volume
11
Issue
7
Pages
2935
ISSN
2076-3417 (ISSN-L)
OpenAlex
W3142331474
Cited by
28
References
52
Citations by year
2026: 2 · 2025: 5 · 2024: 6 · 2023: 9 · 2022: 4 · 2021: 1
FWCI
3.38
Type
journal article
Language
en
Open access
Locations
  • Applied Sciences (publishedVersion, cc-by)
  • KTUePubl (Repository of Kaunas University of Technology) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Lithuanian University of Health Sciences (submittedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Complementary and alternative medicine › Biofield Effects and Biophysics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
Keywords
heart rate variability, geomagnetic field, time-dependent magnetic field, Schumann resonance, autonomic nervous system, magnetometer network

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Global Study of Human Heart Rhythm Synchronization with the Earth’s Time Varying Magnetic Field. https://app.cochat.ai/papers/10.3390/app11072935
The paper
Timofejeva, I., McCraty, R., Atkinson, M., Alabdulgader, A. A., Vainoras, A., Landauskas, M., Šiaučiūnaitė, V., & Ragulskis, M. (2021). Global Study of Human Heart Rhythm Synchronization with the Earth’s Time Varying Magnetic Field. Applied Sciences. https://doi.org/10.3390/app11072935

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.