Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Estimating the Heating Load of Buildings for Smart City Planning Using a Novel Artificial Intelligence Technique PSO-XGBoost

Open access
Le, Le Thi, Nguyen, Hoang, Zhou, Jian, Dou, Jie, Moayedi, Hossein·2019·Applied Sciences

Abstract

In this study, a novel technique to support smart city planning in estimating and controlling the heating load (HL) of buildings, was proposed, namely PSO-XGBoost. Accordingly, the extreme gradient boosting machine (XGBoost) was developed to estimate HL first; then, the particle swarm optimization (PSO) algorithm was applied to optimize the performance of the XGBoost model. The classical XGBoost model, support vector machine (SVM), random forest (RF), Gaussian process (GP), and classification and regression trees (CART) models were also investigated and developed to predict the HL of building systems, and compared with the proposed PSO-XGBoost model; 837 investigations of buildings were considered and analyzed with many influential factors, such as glazing area distribution (GAD), glazing area (GA), orientation (O), overall height (OH), roof area (RA), wall area (WA), surface area (SA), and relative compactness (RC). Mean absolute percentage error (MAPE), root-mean-squared error (RMSE), variance account for (VAF), mean absolute error (MAE), and determination coefficient (R2), were used as the statistical criteria for evaluating the performance of the above models. The color intensity, as well as the ranking method, were also used to compare and evaluate the models. The results showed that the proposed PSO-XGBoost model was the most robust technique for estimating the HL of building systems. The remaining models (i.e., XGBoost, SVM, RF, GP, and CART) yielded more mediocre performance through RMSE, MAE, R2, VAF, and MAPE metrics. Another finding of this study also indicated that OH, RA, WA, and SA were the most critical parameters for the accuracy of the proposed PSO-XGBoost model. They should be particularly interested in smart city planning as well as the optimization of smart cities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app9132714

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 162

Metadata

Authors
Le, L. T., Nguyen, H., Zhou, J., Dou, J., & Moayedi, H.
Venue
Applied Sciences
Publisher
MDPI AG
Published
2019-07-04
Volume
9
Issue
13
Pages
2714
ISSN
2076-3417 (ISSN-L)
OpenAlex
W2953959218
Cited by
162
References
3
FWCI
11.83
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating the Heating Load of Buildings for Smart City Planning Using a Novel Artificial Intelligence Technique PSO-XGBoost. https://app.cochat.ai/papers/10.3390/app9132714
The paper
Le, L. T., Nguyen, H., Zhou, J., Dou, J., & Moayedi, H. (2019). Estimating the Heating Load of Buildings for Smart City Planning Using a Novel Artificial Intelligence Technique PSO-XGBoost. Applied Sciences. https://doi.org/10.3390/app9132714

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.