Cited by 57Building Energy and Comfort OptimizationBuilding energy efficiency and sustainabilityHygrothermal properties of building materials

The DOI matches its Crossref record.

Performance Evaluation of Modern Building Thermal Envelope Designs in the Semi-Arid Continental Climate of Tehran

Open access

Abstract

In this paper we evaluate the thermal performance of a range of modern wall constructions used in the residential buildings of Tehran in order to find the most appropriate alternative to the traditional un-fired clay and brick materials, which are increasingly being replaced in favor of more slender wall constructions employing hollow clay, autoclaved aerated concrete or light expanded clay aggregate blocks. The importance of improving the building envelope through estimating the potential for energy saving due to the application of the most energy-efficient wall type is presented and the wall constructions currently erected in Tehran are introduced along with their dynamic and steady-state thermal properties. The application of a dynamic simulation tool is explained and the output of the thermal simulation model is compared with the dynamic thermal properties of the wall constructions to assess their performance in summer and in winter. Finally, the best and worst wall type in terms of their cyclic thermal performance and their ability to moderate outdoor conditions is identified through comparison of the predicted indoor temperature and a target comfort temperature.

Overview

Integrity signals

Registry

Crossref · 10.3390/buildings3040674

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Research works printed but not linked: 9

  1. Fayaz, 2009, Comparison of energy conservation building codes of Iran, Turkey, Germany, China, ISO 9164 and EN 832, Appl. Energy, 86, 1949, 10.1016/j.apenergy.2008.12.024 · DOI
  2. Crawley, 2008, Contrasting the capabilities of building energy performance simulation programs, Build. Environ., 43, 661, 10.1016/j.buildenv.2006.10.027 · DOI
  3. Heidari, 2009, Comfort temperature for Iranian people in the city of Tehran, Honar-Ha-Ye-Ziba, 1, 5
  4. McMullan, R. (2007). Environmental Science in Buildings, Palgrave Macmillan. [6th ed.].
  5. Gregory, 2008, Effect of thermal mass on the thermal performance of various Australian residential constructions systems, Energy Build., 40, 459, 10.1016/j.enbuild.2007.04.001 · DOI
  6. Balaras, 1996, The role of thermal mass on the cooling load of buildings: An overview of computational methods, Energy Build., 24, 1, 10.1016/0378-7788(95)00956-6 · DOI
  7. Kruger, 2010, Effectiveness of indirect evaporative cooling and thermal mass in a hot arid climate, Build. Environ., 45, 1422, 10.1016/j.buildenv.2009.12.005 · DOI
  8. Nicol, 2002, Adaptive thermal comfort and sustainable thermal standards for buildings, Energy Build., 34, 563, 10.1016/S0378-7788(02)00006-3 · DOI
  9. Hegger, M., Fuchs, M., Stark, Th., and Zeumer, M. (2008). Energy Manual: Sustainable Architecture, Birkhauser. · DOI

Cited by

Sorted by citations

See all 57

Metadata

Authors
Mohammad, S., & Shea, A.
Affiliations
University of Bath (GB)
Corresponding author
Shea, Andrew
Venue
Buildings
Publisher
MDPI AG
Published
2013-10-04
Volume
3
Issue
4
Pages
674-688
ISSN
2075-5309 (ISSN-L)
OpenAlex
W2009782349
Cited by
57
References
0
Citations by year
2026: 2 · 2025: 2 · 2024: 10 · 2023: 7 · 2022: 5 · 2021: 5 · 2020: 4 · 2019: 9 · 2018: 4 · 2017: 4 · 2016: 3 · 2015: 1 · 2014: 1
FWCI
2.91
Type
journal article
Language
en
Open access
Locations
  • Buildings (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
  • Physical Sciences › Engineering › Building and Construction › Hygrothermal properties of building materials
Keywords
building thermal envelope, wall construction, thermal performance, energy conservation, hollow clay bricks, autoclaved aerated concrete, dynamic thermal simulation, indoor temperature, thermal comfort, Tehran

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance Evaluation of Modern Building Thermal Envelope Designs in the Semi-Arid Continental Climate of Tehran. https://app.cochat.ai/papers/10.3390/buildings3040674
The paper
Mohammad, S., & Shea, A. (2013). Performance Evaluation of Modern Building Thermal Envelope Designs in the Semi-Arid Continental Climate of Tehran. Buildings. https://doi.org/10.3390/buildings3040674