Cost-Effectiveness of Artificial Intelligence Support in Computed Tomography-Based Lung Cancer Screening
Open accessAbstract
Background: Lung cancer screening is already implemented in the USA and strongly recommended by European Radiological and Thoracic societies as well. Upon implementation, the total number of thoracic computed tomographies (CT) is likely to rise significantly. As shown in previous studies, modern artificial intelligence-based algorithms are on-par or even exceed radiologist’s performance in lung nodule detection and classification. Therefore, the aim of this study was to evaluate the cost-effectiveness of an AI-based system in the context of baseline lung cancer screening. Methods: In this retrospective study, a decision model based on Markov simulation was developed to estimate the quality-adjusted life-years (QALYs) and lifetime costs of the diagnostic modalities. Literature research was performed to determine model input parameters. Model uncertainty and possible costs of the AI-system were assessed using deterministic and probabilistic sensitivity analysis. Results: In the base case scenario CT + AI resulted in a negative incremental cost-effectiveness ratio (ICER) as compared to CT only, showing lower costs and higher effectiveness. Threshold analysis showed that the ICER remained negative up to a threshold of USD 68 for the AI support. The willingness-to-pay of USD 100,000 was crossed at a value of USD 1240. Deterministic and probabilistic sensitivity analysis showed model robustness for varying input parameters. Conclusion: Based on our results, the use of an AI-based system in the initial low-dose CT scan of lung cancer screening is a feasible diagnostic strategy from a cost-effectiveness perspective.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ziegelmayer et al. reported that AI-assisted low-dose computed tomography remained cost-saving (saving $68 per patient) if the cost per scan stayed below $1240, a threshold confirmed through probabilistic sensitivity analyses.
“Ziegelmayer et al.25 reported that AI-assisted low-dose computed tomography (LDCT) remained cost-saving (saving $68 per patient) if the cost per scan stayed below $1240—a threshold confirmed through extensive probabilistic sensitivity analyses25.”
From Systematic review of cost effectiveness and budget impact of artificial intelligence in healthcare (2025) · cites this paper as Ziegelmayer et al.25
Section 3.3 (page unavailable) says AI support remained cost-saving only while its additional cost was at or below $68 per scan; $1,240 was the limit for cost-effectiveness at a willingness-to-pay of $100,000 per QALY, not for cost savings. Section 3.1 reports approximately $68 lower cumulative cost per patient only in the base case, when the additional AI cost was $0. Sections 3.2–3.3 describe probabilistic sensitivity analysis and threshold analysis separately, rather than saying the former confirmed a cost-saving threshold of $1,240. (LLM, conf=0.90)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredZiegelmayer et al. used up to 30,000 Monte Carlo simulations to demonstrate that AI-assisted LDCT remained cost-saving under various scenarios.
“Ziegelmayer et al.25 used up to 30,000 Monte Carlo simulations to demonstrate that AI-assisted LDCT remained cost-saving under various scenarios.”
From Systematic review of cost effectiveness and budget impact of artificial intelligence in healthcare (2025) · cites this paper as Ziegelmayer et al.25
Methods §2.7 reports a Monte Carlo probabilistic sensitivity analysis with 30,000 iterations, rather than 30,000 separate simulations. Results §3.1 finds lower costs for CT + AI in the base case, but Results §3.2 says the ICER turned positive when specificity varied. Those cases remained cost-effective at the stated willingness-to-pay threshold, not cost-saving. (LLM, conf=0.90)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 43 · Cited by 63
Research works printed but not linked: 37
- [1]Moyer Virginia A. On behalf of the us preventive services task force screening for lung cancer: Us preventive services task force recommendation statement Ann. Intern. Med. 2014 160 330 338 24378917
- [2]National Lung Screening Trial Research Team Reduced lung-cancer mortality with low-dose computed tomographic screening N. Engl. J. Med. 2011 365 395 409 10.1056/NEJMoa1102873 21714641 PMC4356534 · DOI · Paper page
- [3]Oudkerk M. Devaraj A. Vliegenthart R. Henzler T. Prosch H. Heussel C.P. Bastarrika G. Sverzellati N. Mascalchi M. Delorme S. European position statement on lung cancer screening Lancet Oncol. 2017 18 e754 e766 29208441
- [5]Rasmussen J.F. Siersma V. Pedersen J.H. Heleno B. Saghir Z. Brodersen J. Healthcare costs in the danish randomised controlled lung cancer ct-screening trial: A registry study Lung Cancer 2014 83 347 355 10.1016/j.lungcan.2013.12.005 24418526 · DOI
- [6]Wiener R.S. Schwartz L.M. Woloshin S. Welch H.G. Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: An analysis of discharge records Ann. Intern. Med. 2011 155 137 144 10.7326/0003-4819-155-3-201108020-00003 21810706 PMC3150964 · DOI
- [7]Kastner J. Hossain R. Jeudy J. Dako F. Mehta V. Dalal S. Dharaiya E. White C. Lung-rads version 1.0 versus lung-rads version 1.1: Comparison of categories using nodules from the national lung screening trial Radiology 2021 300 203704 33944631
- [8]McKee B.J. Regis S.M. McKee A.B. Flacke S. Wald C. Performance of acr lung-rads in a clinical ct lung screening program J. Am. Coll. Radiol. 2016 13 R25 R29 10.1016/j.jacr.2015.12.009 26846532 · DOI
- [9]Mehta H.J. Mohammed T.-L. Jantz M.A. The american college of radiology lung imaging reporting and data system: Potential drawbacks and need for revision Chest 2017 151 539 543 10.1016/j.chest.2016.07.028 27521737 · DOI
- [10]Singh S. Pinsky P. Fineberg N.S. Gierada D.S. Garg K. Sun Y. Nath P.H. Evaluation of reader variability in the interpretation of follow-up ct scans at lung cancer screening Radiology 2011 259 263 270 10.1148/radiol.10101254 21248232 PMC3064819 · DOI
- [11]McKinney S.M. Sieniek M. Godbole V. Godwin J. Antropova N. Ashrafian H. Back T. Chesus M. Corrado G.S. Darzi A. International evaluation of an ai system for breast cancer screening Nature 2020 577 89 94 10.1038/s41586-019-1799-6 31894144 · DOI · Paper page
- [12]Brown M.S. Goldin J.G. Rogers S. Kim H.J. Suh R.D. McNitt-Gray M.F. Shah S.K. Truong D. Brown K. Sayre J.W. Computer-aided lung nodule detection in ct: Results of large-scale observer test1 Acad. Radiol. 2005 12 681 686 10.1016/j.acra.2005.02.041 15935966 · DOI
- [13]De Hoop B. de Boo D.W. Gietema H.A. van Hoorn F. Mearadji B. Schijf L. van Ginneken B. Prokop M. Schaefer-Prokop C. Computer-aided detection of lung cancer on chest radiographs: Effect on observer performance Radiology 2010 257 532 540 10.1148/radiol.10092437 20807851 · DOI
- [14]Jeon K.N. Goo J.M. Lee C.H. Lee Y. Choo J.Y. Lee N.K. Shim M.-S. Lee I.S. Kim K.G. Gierada D.S. Computer-aided nodule detection and volumetry to reduce variability between radiologists in the interpretation of lung nodules at low-dose screening ct Investig. Radiol. 2012 47 457 10.1097/RLI.0b013e318250a5aa 22717879 PMC3501405 · DOI
- [15]Ardila D. Kiraly A.P. Bharadwaj S. Choi B. Reicher J.J. Peng L. Tse D. Etemadi M. Ye W. Corrado G. End-to-end lung cancer screening with three-dimensional deep learning on low-dose chest computed tomography Nat. Med. 2019 25 954 961 10.1038/s41591-019-0447-x 31110349 · DOI · Paper page
- [16]Arias E. Xu J. Kochanek K.D. United states life tables, 2016 Natl. Vital Stat. Rep. 2019 68 4 31112121
- [17]Cameron D. Ubels J. Norstr öm f: On what basis are medical cost-effectiveness thresholds set Clashing Opin. Absence Data A Syst. Rev. Glob. Health Action 2018 11 1447828 10.1080/16549716.2018.1447828 PMC5930346 29564962 · DOI
- [19]Jacob L. Freyn M. Kalder M. Dinas K. Kostev K. Impact of tobacco smoking on the risk of developing 25 different cancers in the uk: A retrospective study of 422,010 patients followed for up to 30 years Oncotarget 2018 9 17420 10.18632/oncotarget.24724 29707117 PMC5915125 · DOI
- [21]Ten Haaf K. Tammemägi M.C. Bondy S.J. van der Aalst C.M. Gu S. McGregor S.E. Nicholas G. de Koning H.J. Paszat L.F. Performance and cost-effectiveness of computed tomography lung cancer screening scenarios in a population-based setting: A microsimulation modeling analysis in Ontario, Canada PLoS Med. 2017 14 e1002225 10.1371/journal.pmed.1002225 28170394 PMC5295664 · DOI
- [22]Cowper P.A. Feng L. Kosinski A.S. Tong B.C. Habib R.H. Putnam J.B. Jr. Onaitis M.W. Furnary A.P. Wright C.D. Jacobs J.P. Initial and longitudinal cost of surgical resection for lung cancer Ann. Thorac. Surg. 2021 111 1827 1833 10.1016/j.athoracsur.2020.07.048 33031776 · DOI
- [23]Gareen I.F. Duan F. Greco E.M. Snyder B.S. Boiselle P.M. Park E.R. Fryback D. Gatsonis C. Impact of lung cancer screening results on participant health-related quality of life and state anxiety in the national lung screening trial Cancer 2014 120 3401 3409 10.1002/cncr.28833 25065710 PMC4205265 · DOI
- [24]Grutters J.P. Joore M.A. Wiegman E.M. Langendijk J.A. de Ruysscher D. Hochstenbag M. Botterweck A. Lambin P. Pijls-Johannesma M. Health-related quality of life in patients surviving non-small cell lung cancer Thorax 2010 65 903 907 10.1136/thx.2010.136390 20861294 · DOI
- [25]Möller A. Sartipy U. Long-term health-related quality of life following surgery for lung cancer Eur. J. Cardio-Thorac. Surg. 2012 41 362 367 10.1016/j.ejcts.2011.05.055 21733714 · DOI
- [26]Doyle S. Lloyd A. Walker M. Health state utility scores in advanced non-small cell lung cancer Lung Cancer 2008 62 374 380 10.1016/j.lungcan.2008.03.019 18467000 · DOI
- [27]Green A. Hauge J. Iachina M. Jakobsen E. The mortality after surgery in primary lung cancer: Results from the danish lung cancer registry Eur. J. Cardio-Thorac. Surg. 2016 49 589 594 10.1093/ejcts/ezv107 25825264 · DOI
- [28]Toker A. Dilege S. Ziyade S. Eroglu O. Tanju S. Yilmazbayhan D. Kilicarslan Z. Kalayci G. Causes of death within 1 year of resection for lung cancer. Early mortality after resection Eur. J. Cardio-Thorac. Surg. 2004 25 515 519 10.1016/j.ejcts.2004.01.012 15037264 · DOI
- [29]Lou F. Huang J. Sima C.S. Dycoco J. Rusch V. Bach P.B. Patterns of recurrence and second primary lung cancer in early-stage lung cancer survivors followed with routine computed tomography surveillance J. Thorac. Cardiovasc. Surg. 2013 145 75 82 10.1016/j.jtcvs.2012.09.030 23127371 · DOI
- [30]Scholten E.T. Horeweg N. de Koning H.J. Vliegenthart R. Oudkerk M. Willem P.T.M. de Jong P.A. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening Eur. Radiol. 2015 25 81 88 10.1007/s00330-014-3394-4 25187382 · DOI
- [31]Thorsteinsson H. Alexandersson A. Oskarsdottir G.N. Skuladottir R. Isaksson H.J. Jonsson S. Gudbjartsson T. Resection rate and outcome of pulmonary resections for non–small-cell lung cancer: A nationwide study from iceland J. Thorac. Oncol. 2012 7 1164 1169 10.1097/JTO.0b013e318252d022 22592213 · DOI
- [33]Goldstein I.M. Lawrence J. Miner A.S. Human-machine collaboration in cancer and beyond: The centaur care model JAMA Oncol. 2017 3 1303 1304 10.1001/jamaoncol.2016.6413 28152137 · DOI · Paper page
- [34]Liang M. Tang W. Xu D.M. Jirapatnakul A.C. Reeves A.P. Henschke C.I. Yankelevitz D. Low-dose ct screening for lung cancer: Computer-aided detection of missed lung cancers Radiology 2016 281 279 288 10.1148/radiol.2016150063 27019363 · DOI · Paper page
- [35]Wolff J. Pauling J. Keck A. Baumbach J. Systematic review of economic impact studies of artificial intelligence in health care J. Med. Internet Res. 2020 22 e16866 10.2196/16866 32130134 PMC7059082 · DOI
- [36]Pastorino U. Rossi M. Rosato V. Marchianò A. Sverzellati N. Morosi C. Fabbri A. Galeone C. Negri E. Sozzi G. Annual or biennial ct screening versus observation in heavy smokers: 5-year results of the mild trial Eur. J. Cancer Prev. 2012 21 308 315 10.1097/CEJ.0b013e328351e1b6 22465911 · DOI
- [37]Van Klaveren R.J. Oudkerk M. Prokop M. Scholten E.T. Nackaerts K. Vernhout R. van Iersel C.A. van den Bergh K.A. Westeinde S.V. van der Aalst C. Management of lung nodules detected by volume ct scanning N. Engl. J. Med. 2009 361 2221 2229 10.1056/NEJMoa0906085 19955524 · DOI
- [38]Van den Bergh K.A. Essink-Bot M.-L. Borsboom G.J. Scholten E.T. Prokop M. de Koning H.J. van Klaveren R.J. Short-term health-related quality of life consequences in a lung cancer ct screening trial (nelson) Br. J. Cancer 2010 102 27 34 10.1038/sj.bjc.6605459 19935789 PMC2813757 · DOI
- [39]Jonas D.E. Reuland D.S. Reddy S.M. Nagle M. Clark S.D. Weber R.P. Enyioha C. Malo T.L. Brenner A.T. Armstrong C. Screening for lung cancer with low-dose computed tomography: Updated evidence report and systematic review for the us preventive services task force JAMA 2021 325 971 987 10.1001/jama.2021.0377 33687468 · DOI
- [41]Hoverman J.R. Klein I. Harrison D.W. Hayes J.E. Garey J.S. Harrell R. Sipala M. Houldin S. Jameson M.D. Abdullahpour M. Opening the black box: The impact of an oncology management program consisting of level i pathways and an outbound nurse call system J. Oncol. Pract. 2014 10 63 67 10.1200/JOP.2013.001210 24443735 · DOI
- [42]Peng S. Liu Y. Lv W. Liu L. Zhou Q. Yang H. Ren J. Liu G. Wang X. Zhang X. Deep learning-based artificial intelligence model to assist thyroid nodule diagnosis and management: A multicentre diagnostic study Lancet Digit. Health 2021 3 e250 e259 10.1016/S2589-7500(21)00041-8 33766289 · DOI
- Authors
- Ziegelmayer, S., Graf, M., Makowski, M., Gawlitza, J., & Gassert, F.
- Affiliations
- TUM Klinikum (DE)
- Corresponding author
- Ziegelmayer, Sebastian
- Venue
- Cancers
- Publisher
- MDPI AG
- Published
- 2022-03-29
- Volume
- 14
- Issue
- 7
- Pages
- 1729
- ISSN
- 2072-6694 (ISSN-L)
- PMC
- PMC8997030
- OpenAlex
- W4221017734
- Cited by
- 63
- References
- 43
- Citations by year
- 2026: 14 · 2025: 24 · 2024: 11 · 2023: 10 · 2022: 4
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Cancers (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Keywords
- lung cancer screening, artificial intelligence, computer-aided detection, low-dose CT, cost-effectiveness, quality-adjusted life years, lung nodule detection, Markov decision process, incremental cost-effectiveness ratio, willingness-to-pay threshold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review