CoChat

Recent Advancements in Surface Modification, Characterization and Functionalization for Enhancing the Biocompatibility and Corrosion Resistance of Biomedical Implants

Open access
Thakur, Abhinay, Kumar, Ashish, Kaya, Savaş, Marzouki, Riadh, Zhang, Fan, Guo, Lei · 2022 · Coatings
Cited by 229

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

Abstract

Metallic materials are among the most crucial engineering materials widely utilized as biomaterials owing to their significant thermal conductivity, mechanical characteristics, and biocompatibility. Although these metallic biomedical implants, such as stainless steel, gold, silver, dental amalgams, Co-Cr, and Ti alloys, are generally used for bone tissue regeneration and repairing bodily tissue, the need for innovative technologies is required owing to the sensitivity of medical applications and to avoid any potential harmful reactions, thereby improving the implant to bone integration and prohibiting infection lea by corrosion and excessive stress. Taking this into consideration, several research and developments in biomaterial surface modification are geared toward resolving these issues in bone-related medical therapies/implants offering a substantial influence on cell adherence, increasing the longevity of the implant and rejuvenation along with the expansion in cell and molecular biology expertise. The primary objective of this review is to reaffirm the significance of surface modification of biomedical implants by enlightening numerous significant physical surface modifications, including ultrasonic nanocrystal surface modification, thermal spraying, ion implantation, glow discharge plasma, electrophoretic deposition, and physical vapor deposition. Furthermore, we also focused on the characteristics of some commonly used biomedical alloys, such as stainless steel, Co-Cr, and Ti alloys.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/coatings12101459

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Metadata

Authors
Thakur, A., Kumar, A., Kaya, S., Marzouki, R., Zhang, F., & Guo, L.
Venue
Coatings
Publisher
MDPI AG
Published
2022-10-03
Volume
12
Issue
10
Pages
1459
ISSN
2079-6412 (ISSN-L)
OpenAlex
W4303628122
Cited by
229
References
63
FWCI
15.69
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recent Advancements in Surface Modification, Characterization and Functionalization for Enhancing the Biocompatibility and Corrosion Resistance of Biomedical Implants. https://app.cochat.ai/papers/10.3390/coatings12101459
The paper
Thakur, A., Kumar, A., Kaya, S., Marzouki, R., Zhang, F., & Guo, L. (2022). Recent Advancements in Surface Modification, Characterization and Functionalization for Enhancing the Biocompatibility and Corrosion Resistance of Biomedical Implants. Coatings. https://doi.org/10.3390/coatings12101459

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.