Segmentation-Based Classification Deep Learning Model Embedded with Explainable AI for COVID-19 Detection in Chest X-ray Scans
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background and Motivation: COVID-19 has resulted in a massive loss of life during the last two years. The current imaging-based diagnostic methods for COVID-19 detection in multiclass pneumonia-type chest X-rays are not so successful in clinical practice due to high error rates. Our hypothesis states that if we can have a segmentation-based classification error rate <5%, typically adopted for 510 (K) regulatory purposes, the diagnostic system can be adapted in clinical settings. Method: This study proposes 16 types of segmentation-based classification deep learning-based systems for automatic, rapid, and precise detection of COVID-19. The two deep learning-based segmentation networks, namely UNet and UNet+, along with eight classification models, namely VGG16, VGG19, Xception, InceptionV3, Densenet201, NASNetMobile, Resnet50, and MobileNet, were applied to select the best-suited combination of networks. Using the cross-entropy loss function, the system performance was evaluated by Dice, Jaccard, area-under-the-curve (AUC), and receiver operating characteristics (ROC) and validated using Grad-CAM in explainable AI framework. Results: The best performing segmentation model was UNet, which exhibited the accuracy, loss, Dice, Jaccard, and AUC of 96.35%, 0.15%, 94.88%, 90.38%, and 0.99 (p-value <0.0001), respectively. The best performing segmentation-based classification model was UNet+Xception, which exhibited the accuracy, precision, recall, F1-score, and AUC of 97.45%, 97.46%, 97.45%, 97.43%, and 0.998 (p-value <0.0001), respectively. Our system outperformed existing methods for segmentation-based classification models. The mean improvement of the UNet+Xception system over all the remaining studies was 8.27%. Conclusion: The segmentation-based classification is a viable option as the hypothesis (error rate <5%) holds true and is thus adaptable in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Can AI help in screening viral and COVID-19 pneumonia?
Chowdhury, M. E. H., Rahman, T., Khandakar, A., Mazhar, R., Kadir, M. A., Mahbub, Z. B., Islam, K. R., Khan, M. S., Iqbal, A., Emadi, N. A., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3010287 · Cited by 1,913 · cited 4×
“(2020) [60] COVID-19 Radiography database (Kaggle) (423 + 3064) CheXNet 3 class-97.”
BackgroundMethodInfluentialGeneralized Cross Entropy Loss for Training Deep Neural Networks with Noisy Labels
Zhang, Z., & Sabuncu, M. R. (2018) · arXiv · doi:10.48550/arxiv.1805.07836 · Cited by 1,907 · cited 1×
“The mathematical representations for the matrices are given in the equation below [37,55,56]: Jaccard index = TP ( TP + FN + FP ) For the classification phase of experiment, a total of 12,926 chest X-ray images were used.”
MethodSecure, privacy-preserving and federated machine learning in medical imaging
Kaissis, G. A., Makowski, M. R., Rückert, D., & Braren, R. F. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-0186-1 · Cited by 1,676
Estimation of prediction error by using K-fold cross-validation
Fushiki, T. (2011) · Statistics and Computing · doi:10.1007/s11222-009-9153-8 · Cited by 1,470
Reliable Accuracy Estimates from k-Fold Cross Validation
Wong, T.-T., & Yeh, P.-Y. (2020) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2019.2912815 · Cited by 1,074 · cited 2×
“The 5‐fold cross‐validation is the most popular protocol, where 80% of images are used for training and 20% for testing the model [51,52].”
BackgroundMethodChrist, P. F., Elshaer, M. E. A., Ettlinger, F., Tatavarty, S., Bickel, M., Bilic, P., Rempfler, M., Armbruster, M., Hofmann, F., D’Anastasi, M., et al. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_48 · Cited by 625
The present and future of deep learning in radiology
Saba, L., Biswas, M., Kuppili, V., Cuadrado Godia, E., Suri, H. S., Edla, D. R., Omerzu, T., Laird, J. R., Khanna, N. N., Mavrogeni, S., et al. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.02.038 · Cited by 353
Self-citationWehbe, R. M., Sheng, J., Dutta, S., Chai, S., Dravid, A., Barutcu, S., Wu, Y., Cantrell, D. R., Xiao, N., Allen, B. D., et al. (2021) · Radiology · doi:10.1148/radiol.2020203511 · Cited by 190
Cited by
Economics of artificial intelligence in healthcare: Diagnosis vs. treatment
Khanna, N. N., Maindarkar, M. A., Viswanathan, V., Fernandes, J. F. E., Paul, S., Bhagawati, M., Ahluwalia, P., Ruzsa, Z., Sharma, A., Kolluri, R., et al. (2022) · Healthcare · doi:10.3390/healthcare10122493 · Cited by 347
Self-citationYuan, H., Yu, K., Xie, F., Liu, M., & Sun, S. (2024) · Medicine Advances · doi:10.1002/med4.75 · Cited by 61
Pawar, L., Patil, S., Dhotre, S., & Sonawane, S. (2024) · 2024 8th International Artificial Intelligence and Data Processing Symposium (IDAP) · doi:10.1109/idap64064.2024.10710903 · Cited by 5
Metadata
- Authors
- Nillmani, Sharma, N., Saba, L., Khanna, N., Kalra, M., Fouda, M., & Suri, J.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2022-09-02
- Volume
- 12
- Issue
- 9
- Pages
- 2132
- ISSN
- 2075-4418 (ISSN-L)
- OpenAlex
- W4294675761
- Cited by
- 100
- References
- 11
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.