Ferritin: A Biomarker Requiring Caution in Clinical Decision

Open access
Lemaire, Baptiste, Frias, Miguel A., Golaz, Olivier, Magnin, Jean-Luc, Viette, Véronique, Vuilleumier, Nicolas, Waldvogel Abramowski, Sophie · 2024 · Diagnostics

Abstract

Objectives. To determine the ferritin inter-assay differences between three “Conformité Européenne” (CE) marked tests, the impact on reference intervals (RI), and the proportion of individuals with iron deficiency (ID), we used plasma and serum from healthy blood donors (HBD) recruited in three different Switzerland regions. Design and Methods. Heparinized plasma and serum from HBD were obtained from three different transfusion centers in Switzerland (Fribourg, Geneva, and Neuchatel). One hundred forty samples were recruited per center and per matrix, with a gender ratio of 50%, for a total of 420 HBD samples available per matrix. On both matrices, ferritin concentrations were quantified by three different laboratories using electrochemiluminescence (ECL), latex immunoturbidimetric assay (LIA), and luminescent oxygen channeling immunoassay (LOCI) assays, respectively. The degree of agreement between matrices and between the three sites/methods was assessed by Passing–Bablok and we evaluated the proportion of individuals deemed to have ID per method. Results. Overall, no difference between serum and heparinized plasma ferritin values was observed according to Passing–Bablok analyses (proportional bias range: 1.0–3.0%; maximum constant bias: 1.84 µg/L). Significant median ferritin differences (p < 0.001 according to Kruskal–Wallis test) were observed between the three methods (i.e., 83.6 µg/L, 103.5 µg/L, and 62.1 µg/L for ECL, LIA, and LOCI in heparinized plasma, respectively), with proportional bias varying significantly between ±16% and ±32% on serum and from ±14% to ±35% on plasma with no sign of gender-related differences. Affecting the lower end of RI, the proportion of ID per method substantially varied between 4.76% (20/420) for ECL, 2.86% (12/420) for LIA, and 9.05% (38/420) for LOCI. Conclusions. Serum and heparinized plasma are exchangeable for ferritin assessment. However, the order of magnitude of ferritin differences across methods and HBD recruitment sites could lead to diagnostic errors if uniform RI were considered. Challenging the recently proposed use of uniform ferritin thresholds, our results highlight the importance of method- and region-specific RI for ferritin due to insufficient inter-assay harmonization. Failing to do so significantly impacts ID diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/diagnostics14040386

Cites

Statistics

Figures

Figure 1 Flowchart showing the distribution of the 840 samples between laboratories. N: number of blood donors. n: number of samples. ECL: electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.
Figure 1 Flowchart showing the distribution of the 840 samples between laboratories. N: number of blood donors. n: number of samples. ECL: electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.CC BY · PubMed Central
Figure 2 Comparison of matrices between serum and heparinized plasma. Passing–Bablok analyses were performed by ECL (A,B), LIA (C,D), and LOCI (E,F) for men and women, respectively. ECL: electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.
Figure 2 Comparison of matrices between serum and heparinized plasma. Passing–Bablok analyses were performed by ECL (A,B), LIA (C,D), and LOCI (E,F) for men and women, respectively. ECL: electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.CC BY · PubMed Central
Figure 3 Comparison of the three methods using the Kruskal–Wallis test. ECL: Electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.
Figure 3 Comparison of the three methods using the Kruskal–Wallis test. ECL: Electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.CC BY · PubMed Central
Figure 4 Comparison of the three methods two by two using the Passing–Bablok analyses, performed with heparinized plasma between the ECL and LIA methods (A), LOCI and ECL methods (B), and LOCI and LIA methods (C). ECL: electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.
Figure 4 Comparison of the three methods two by two using the Passing–Bablok analyses, performed with heparinized plasma between the ECL and LIA methods (A), LOCI and ECL methods (B), and LOCI and LIA methods (C). ECL: electrochemiluminescence. LIA: latex immunoturbidimetric assay. LOCI: luminescent oxygen channeling immunoassay.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 25 · Cited by 4

Research works printed but not linked: 1

  1. Institute of Medicine (US) Panel on Micronutrients (2001). Dietary Reference Intakes for Vitamin A, Vitamin K, Arsenic, Boron, Chromium, Copper, Iodine, Iron, Manganese, Molybdenum, Nickel, Silicon, Vanadium, and Zinc, National Academies Press.

Metadata

Authors
Lemaire, B., Frias, M. A., Golaz, O., Magnin, J.-L., Viette, V., Vuilleumier, N., & Waldvogel Abramowski, S.
Affiliations
  • University Hospital of Geneva (CH)
  • HFR Freiburg Kantonsspital (CH)
  • ADMED (Switzerland) (CH)
  • Diagnostic Department, Geneva University Hospitals, 1205 Geneva, Switzerland
Venue
Diagnostics
Publisher
MDPI AG
Published
2024-02-10
Volume
14
Issue
4
Pages
386
ISSN
2075-4418 (ISSN-L)
OpenAlex
W4391747228
Cited by
4
References
25
Citations by year
2026: 2 · 2025: 1 · 2024: 1
FWCI
1.13
Type
journal article
Language
en
Open access
Locations
  • Diagnostics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
  • Health Sciences › Medicine › Hematology › Hematological disorders and diagnostics
Keywords
ferritin, iron deficiency, reference values, electrochemiluminescence assay, healthy blood donors, diagnostic thresholds, assay harmonization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ferritin: A Biomarker Requiring Caution in Clinical Decision. https://app.cochat.ai/papers/10.3390/diagnostics14040386
The paper
Lemaire, B., Frias, M. A., Golaz, O., Magnin, J.-L., Viette, V., Vuilleumier, N., & Waldvogel Abramowski, S. (2024). Ferritin: A Biomarker Requiring Caution in Clinical Decision. Diagnostics. https://doi.org/10.3390/diagnostics14040386

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.