AC-DC Converters for Electrolyzer Applications: State of the Art and Future Challenges
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The main objective of the article is to provide a thorough review of currently used AC-DC converters for alkaline and proton exchange membrane (PEM) electrolyzers in power grid or wind energy conversion systems. Based on the current literature, this article aims at emphasizing the advantages and drawbacks of AC-DC converters mainly based on thyristor rectifier bridges and chopper-rectifiers. The analysis is mainly focused on the current issues for these converters in terms of specific energy consumption, current ripple, reliability, efficiency, and power quality. From this analysis, it is shown that thyristors-based rectifiers are particularly fit for high-power applications but require the use of active and passive filters to enhance the power quality. By comparison, the association combination of the chopper-rectifier can avoid the use of bulky active and passive filters since it can improve power quality. However, the use of a basic chopper (i.e., buck converter) presents several disadvantages from the reliability, energy efficiency, voltage ratio, and current ripple point of view. For this reason, new emerging DC-DC converters must be employed to meet these important issues according to the availability of new power switching devices. Finally, based on the authors’ experience in power conversion for PEM electrolyzers, a discussion is provided regarding the future challenges that must face power electronics for green hydrogen production based on renewable energy sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Wide Bandgap Power Semiconductor Devices
Millán, J., Godignon, P., Perpiñà, X., Pérez-Tomás, A., & Rebollo, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2268900 · Cited by 2,685
Buttler, A., & Spliethoff, H. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.003 · Cited by 2,510 · cited 3×
“In hydrogen production pathways based on renewable energy sources, produced and stored hydrogen can be employed for various applications as shown in Figure 1 [8,10]:”
BackgroundMethodGandía, L. M., Arzamendi, G., & Diéguez, P. M. (2013) · Renewable Hydrogen Technologies · doi:10.1016/b978-0-444-56352-1.00001-5 · Cited by 65
Cited by
An overview of water electrolysis technologies for green hydrogen production
Shiva Kumar, S., & Lim, H. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.10.127 · Cited by 1,526
State-of-the-art hydrogen generation techniques and storage methods: A critical review
Tang, D., Tan, G.-L., Li, G.-W., Liang, J.-G., Ahmad, S. M., Bahadur, A., Humayun, M., Ullah, H., Khan, A., & Bououdina, M. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.107196 · Cited by 297
Guilbert, D., & Vitale, G. (2021) · Clean Technologies · doi:10.3390/cleantechnol3040051 · Cited by 195
“4 A·cm−2) and a slow response to dynamic operations [36].”
BackgroundSelf-citation
Metadata
- Authors
- Yodwong, B., Guilbert, D., Phattanasak, M., Kaewmanee, W., Hinaje, M., & Vitale, G.
- Venue
- Electronics
- Publisher
- MDPI AG
- Published
- 2020-05-29
- Volume
- 9
- Issue
- 6
- Pages
- 912
- ISSN
- 2079-9292 (ISSN-L)
- OpenAlex
- W3030778130
- Cited by
- 182
- References
- 3
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.