Assessment of the Use of Venetian Blinds as Solar Thermal Collectors in Double Skin Facades in Mediterranean Climates
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The global trend on energy integration and building efficiency is making both researchers and building developers look for technical solutions to use facade surfaces for energy harvesting. In this work, the assessment of the thermal performance of a double-skin facade (DSF) with a venetian blind-type of structure used as a solar thermal collector by means of computational fluid dynamics (CFD) is presented. A Venetian blind collector would allow for heat rejection/energy harvesting and exterior views simultaneously and can be easily integrated into the DSF aesthetical design. For the purposes of this study, the modeled facades (south, west, and east-oriented) were set to be located in Barcelona (Spain), where large solar gains are a constant condition throughout the year, and such large semi-transparent envelopes lead to interior over-heating in buildings, even during the winter. For the studied facades, both the reductions in radiative heat gains entering the building and the heat recovery in the Venetian blind collector were evaluated for a yearlong operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The solar heat gains observed in an experimental setup in China were reduced from 330 to 28 W/m 2 with Venetian blinds [149].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [149]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pinel, P., Cruickshank, C. A., Beausoleil-Morrison, I., & Wills, A. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.04.013 · Cited by 536
Energy and cost analysis of semi-transparent photovoltaic in office buildings
Li, D. H. W., Lam, T. N. T., Chan, W. W. H., & Mak, A. H. L. (2009) · Applied Energy · doi:10.1016/j.apenergy.2008.08.009 · Cited by 235 · cited 1×
“A previously validated modeling strategy [11] was used to obtain the presented results, consolidating the idea that CFD can offer tailored solutions for DSF-VB thermal collectors’ performance assessment.”
MethodAnalysis of thermal and electrical performance of semi-transparent photovoltaic (PV) module
Park, K. E., Kang, G. H., Kim, H. I., Yu, G. J., & Kim, J. T. (2010) · Energy · doi:10.1016/j.energy.2009.07.019 · Cited by 194
Pasut, W., & Carli, M. D. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.11.028 · Cited by 179 · cited 2×
“Obtained average surface and cavity temperatures for the studied DSF-VB thermal collector system were in all cases lower than the values reported for DSF with mechanical air ventilation operating under similar climatic conditions [6,8,16].”
MethodResultSafer, N., Woloszyn, M., & Roux, J. J. (2005) · Solar Energy · doi:10.1016/j.solener.2004.09.016 · Cited by 169 · cited 1×
“Windows and DSF with VB have also been studied by means of CFD modeling [19,20].”
MethodOptimal operation of a south double-skin facade
Gratia, E., & De Herde, A. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2003.06.001 · Cited by 160 · cited 1×
“, Northern Europe), it has been proven that the use of DSF reduces the heating loads during winter and increases the cooling loads of the building during summer [7].”
BackgroundA comprehensive review of solar facades. Transparent and translucent solar facades
Quesada, G., Rousse, D., Dutil, Y., Badache, M., & Hallé, S. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.059 · Cited by 158 · cited 1×
“[12] reviewed scientific studies carried out on transparent and translucent ASF during the first decade of this century.”
BackgroundValidation of CFD simulation for flat plate solar energy collector
Selmi, M., Al-Khawaja, M. J., & Marafia, A. (2007) · Renewable Energy · doi:10.1016/j.renene.2007.02.003 · Cited by 153 · cited 1×
“Previous works on this subject include the study of flat plate solar energy collectors [23,24], polymer solar collectors [25,26], solar collectors with horizontally inclined absorber strips [27], and tilted wavy solar collectors [28] on integrated collector storage devices [29,30], among others.”
BackgroundFlow distribution in a solar collector panel with horizontally inclined absorber strips
Fan, J., Shah, L. J., & Furbo, S. (2007) · Solar Energy · doi:10.1016/j.solener.2007.02.001 · Cited by 114
Total solar energy transmittance of glass double façades with free convection
Manz, H. (2003) · Energy and Buildings · doi:10.1016/j.enbuild.2003.10.003 · Cited by 110 · cited 1×
“Manz [17] evaluated the total solar transmittance of a DSF with free convection using CFD techniques.”
Method
Research works printed but not linked: 4
- Calorimetric analysis of the solar and thermal performance of windows with interior louvered blinds. M R Collins, S J Harrison, Trans. Am. Soc. Heat. Refrig. Air Cond. Eng. 110152004. 2017
- convective heat transfer from a window with a Venetian blind: Detailed modelling. Iashrae Trans. P Ye, S J Harrison, P H Oosthuizen, 19991031
- Thermal surface finishes. D G Gilmore, W K Stuckey, M Fong, D G Gilmore, Ed, Spacecraft Thermal Control Handbook. Segundo, CA, USAEl200212nd ed
- Uso De La Radiación Solar En DFA Para La Reducción De Cargas De Enfriamiento. A Ravello, 2017Barcelona, SpainUniversitat Politècnica de CatalunyaBachelor's Thesis
Cited by
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Climate-Adaptive Façades with an Air Chamber
Kotlyarskaya, I. L., Nemova, D. V., Vatin, N. I., Федюк, Р. С., & Karelina, M. Y. (2022) · Buildings · doi:10.3390/buildings12030366 · Cited by 27
Jun, Y.-J., Park, K.-S., & Song, Y.-H. (2021) · Solar Energy · doi:10.1016/j.solener.2021.10.019 · Cited by 20
Review of Energy Harvesting for Buildings Based on Solar Energy and Thermal Materials
Sucupira, L., & Castro-Gomes, J. P. (2021) · CivilEng · doi:10.3390/civileng2040046 · Cited by 14
Iribarren, V. E., Rizo-Maestre, C., & Echarri, F. (2018) · Energies · doi:10.3390/en11102707 · Cited by 10
“These values were compared with other sources and publications, and correl tive values were obtained [72,73].”
Result
Metadata
- Authors
- Velasco, A., Jiménez García, S., Guardo, A., Fontanals, A., & Egusquiza, M.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- Centre de Diagnòstic Industrial i Fluidodinàmica, Universitat Politècnica de Catalunya BarcelonaTECH (UPC CDIF), Av. Diagonal 647, 08028 Barcelona, Spain
- Corresponding author
- Guardo, Alfredo
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2017-11-10
- Volume
- 10
- Issue
- 11
- Pages
- 1825
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2768064806
- Cited by
- 16
- References
- 27
- Citations by year
- 2026: 2 · 2024: 1 · 2023: 3 · 2022: 5 · 2021: 4 · 2018: 1
- FWCI
- 0.21
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, cc-by-nc-nd)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (publishedVersion, cc-by-nc-nd)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (submittedVersion, cc-by-nc-nd)
- Funders
- California State University, Chico
- Topics
- Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Solar Thermal and Photovoltaic Systems
- Keywords
- venetian blinds, double-skin facade, solar thermal collectors, heat recovery, building thermal performance, Mediterranean climate, Barcelona, facade orientation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of the Use of Venetian Blinds as Solar Thermal Collectors in Double Skin Facades in Mediterranean Climates. https://app.cochat.ai/papers/10.3390/en10111825
- The paper
- Velasco, A., Jiménez García, S., Guardo, A., Fontanals, A., & Egusquiza, M. (2017). Assessment of the Use of Venetian Blinds as Solar Thermal Collectors in Double Skin Facades in Mediterranean Climates. Energies. https://doi.org/10.3390/en10111825
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.