Real-Time Energy Management of a Microgrid Using Deep Reinforcement Learning
Open accessAbstract
Driven by the recent advances and applications of smart-grid technologies, our electric power grid is undergoing radical modernization. Microgrid (MG) plays an important role in the course of modernization by providing a flexible way to integrate distributed renewable energy resources (RES) into the power grid. However, distributed RES, such as solar and wind, can be highly intermittent and stochastic. These uncertain resources combined with load demand result in random variations in both the supply and the demand sides, which make it difficult to effectively operate a MG. Focusing on this problem, this paper proposed a novel energy management approach for real-time scheduling of an MG considering the uncertainty of the load demand, renewable energy, and electricity price. Unlike the conventional model-based approaches requiring a predictor to estimate the uncertainty, the proposed solution is learning-based and does not require an explicit model of the uncertainty. Specifically, the MG energy management is modeled as a Markov Decision Process (MDP) with an objective of minimizing the daily operating cost. A deep reinforcement learning (DRL) approach is developed to solve the MDP. In the DRL approach, a deep feedforward neural network is designed to approximate the optimal action-value function, and the deep Q-network (DQN) algorithm is used to train the neural network. The proposed approach takes the state of the MG as inputs, and outputs directly the real-time generation schedules. Finally, using real power-grid data from the California Independent System Operator (CAISO), case studies are carried out to demonstrate the effectiveness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-level control through deep reinforcement learning
Mnih, V., Kavukcuoglu, K., Silver, D., Rusu, A. A., Veness, J., Bellemare, M. G., Graves, A., Riedmiller, M., Fidjeland, A. K., Ostrovski, G., et al. (2015) · Nature · doi:10.1038/nature14236 · Cited by 30,357
Mastering the game of Go with deep neural networks and tree search
Silver, D., Huang, A., Maddison, C. J., Guez, A., Sifre, L., van den Driessche, G., Schrittwieser, J., Antonoglou, I., Panneershelvam, V., Lanctot, M., et al. (2016) · Nature · doi:10.1038/nature16961 · Cited by 15,612
Smart Grid — The New and Improved Power Grid: A Survey
Fang, X., Misra, S., Xue, G., & Yang, D. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.101911.00087 · Cited by 3,405
Self-citationFarhangi, H. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2009.934876 · Cited by 2,870
For the Grid and Through the Grid: The Role of Power Line Communications in the Smart Grid
Galli, S., Scaglione, A., & Wang, Z. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2109670 · Cited by 1,002
Battery Energy Storage System (BESS) and Battery Management System (BMS) for Grid-Scale Applications
Lawder, M. T., Suthar, B., Northrop, P. W. C., De, S., Hoff, C. M., Leitermann, O., Crow, M. L., Santhanagopalan, S., & Subramanian, V. R. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2317451 · Cited by 713
Zhou, H., Bhattacharya, T., Tran, D., Siew, T. S. T., & Khambadkone, A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095040 · Cited by 704
Control and Operation of a DC Microgrid With Variable Generation and Energy Storage
Xu, L., & Chen, D. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2158456 · Cited by 567
A BENCHMARK LOW VOLTAGE MICROGRID NETWORK
Papathanassiou, S. A., Hatziargyriou, N. D., & Strunz, K. (2005) · Cited by 419
Dynamic Energy Management System for a Smart Microgrid
Venayagamoorthy, G. K., Sharma, R. K., Gautam, P. K., & Ahmadi, A. (2016) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2016.2514358 · Cited by 328
Cited by
A Review of Deep Reinforcement Learning for Smart Building Energy Management
Yu, L., Qin, S., Zhang, M., Shen, C., Jiang, T., & Guan, X. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3078462 · Cited by 476
Applications of reinforcement learning in energy systems
Perera, A. T. D., & Kamalaruban, P. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110618 · Cited by 420
Li, J., Herdem, M. S., Nathwani, J., & Wen, J. Z. (2023) · Energy and AI · doi:10.1016/j.egyai.2022.100208 · Cited by 409
Deep reinforcement learning for energy management in a microgrid with flexible demand
Nakabi, T. A., & Toivanen, P. (2021) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2020.100413 · Cited by 306
Deep Reinforcement Learning for Autonomous Internet of Things: Model, Applications and Challenges
Lei, L., Tan, Y., Zheng, K., Liu, S., Zhang, K., & Shen, X. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2988367 · Cited by 298
Metadata
- Authors
- Ji, Y., Wang, J., Xu, J., Fang, X., & Zhang, H.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2019-06-15
- Volume
- 12
- Issue
- 12
- Pages
- 2291
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2952242647
- Cited by
- 275
- References
- 22
- FWCI
- 14.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Energy Management of a Microgrid Using Deep Reinforcement Learning. https://app.cochat.ai/papers/10.3390/en12122291
- The paper
- Ji, Y., Wang, J., Xu, J., Fang, X., & Zhang, H. (2019). Real-Time Energy Management of a Microgrid Using Deep Reinforcement Learning. Energies. https://doi.org/10.3390/en12122291
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.