CoChat

Internal Heat Gains in a Lunar Base—A Contemporary Case Study

Open access

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

The Moon’s environmental conditions present limited opportunities for waste heat dissipation, so internal heat gains (IHG) are a key component of thermal balance in a lunar building. Despite the significant development in energy saving and energy storage technologies of the last thirty years, the issue of IHG in lunar buildings has not been readdressed since the early 1990s. This study is based on an inspection of internal heat sources conducted aboard LUNARES, the first European extraterrestrial analogue habitat. The equipment absent on LUNARES, but indispensable for an actual lunar base, was identified and accounted for, along with additional laboratory and maintenance equipment. Three main groups of internal heat sources were identified and studied in detail. Waste heat generated by electric devices was accounted for, along with occupational heat loads adjusted for lunar partial gravity conditions. Assuming a photovoltaic power source for the studied building, two alternative energy storage systems (ESS) were analysed as another source of waste heat. Depending on the time of lunar day and applied ESS, the nominal IHG were between 73 and 133 W/m2. The most significant internal heat sources in a lunar base are life support systems and potentially, regenerative fuel cells; thus, lithium–ion batteries were recommended for ESS. Within assumed parameter range, parametric study exhibited differences in IHG between 41.5 and 163 W/m2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en13123213

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 An axonometric projection of the LUNARES habitat three-dimensional (3D) model. Source: Leszek Orzechowski and Agata Mintus . Figure 1. An axonometric projection of the LUNARES habitat three-dimensional (3D) model. Source: Leszek Orzechowski and Agata Mintus.
Figure 1 An axonometric projection of the LUNARES habitat three-dimensional (3D) model. Source: Leszek Orzechowski and Agata Mintus . Figure 1. An axonometric projection of the LUNARES habitat three-dimensional (3D) model. Source: Leszek Orzechowski and Agata Mintus.CC-BY · From the PDF
Figure 2 LUNARES and its vicinity. Source: Space is More . Figure 2. LUNARES and its vicinity. Source: Space is More.
Figure 2 LUNARES and its vicinity. Source: Space is More . Figure 2. LUNARES and its vicinity. Source: Space is More.CC-BY · From the PDF
Figure 3 Heat loads from electrical devices. Figure 3. Heat loads from electrical devices.
Figure 3 Heat loads from electrical devices. Figure 3. Heat loads from electrical devices.CC-BY · From the PDF
Figure 4 Total occupational heat loads and its components. Figure 4. Total occupational heat loads and its components.
Figure 4 Total occupational heat loads and its components. Figure 4. Total occupational heat loads and its components.CC-BY · From the PDF
Figure 5 Internal heat loads in the lunar base during the lunar cycle. Figure 5. Internal heat loads in the lunar base during the lunar cycle.
Figure 5 Internal heat loads in the lunar base during the lunar cycle. Figure 5. Internal heat loads in the lunar base during the lunar cycle.CC-BY · From the PDF
Figure 6 Nominal operations heat load distribution for the three categories of electrical devices. Figure 6. Nominal operations heat load distribution for the three categories of electrical devices.
Figure 6 Nominal operations heat load distribution for the three categories of electrical devices. Figure 6. Nominal operations heat load distribution for the three categories of electrical devices.CC-BY · From the PDF
Figure 7 Ratios of the obtained internal heat gains (IHG) to the reference values. Figure 7. Ratios of the obtained internal heat gains (IHG) to the reference values.
Figure 7 Ratios of the obtained internal heat gains (IHG) to the reference values. Figure 7. Ratios of the obtained internal heat gains (IHG) to the reference values.CC-BY · From the PDF
Figure 8 Dependence of the total IHG on the number of base inhabitants. Figure 8. Dependence of the total IHG on the number of base inhabitants.
Figure 8 Dependence of the total IHG on the number of base inhabitants. Figure 8. Dependence of the total IHG on the number of base inhabitants.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Research works printed but not linked: 4

  1. Kaczmarzyk, 2019, Internal heat loads in the LUNARES analogue planetary base—A case study, J. Civ. Eng. Environ. Archit., 3, 25
  2. Goodfellow, H.D., and Tahti, E. (2001). Industrial Ventilation Design Guidebook, Elsevier. Available online: https://books.google.com/books/about/Industrial_Ventilation_Design_Guidebook.html?id=t9O8xvY_XoUC.
  3. Grigore, R., and Dima, C. (2015). Research on the influence of internal heat gains on energy performance evaluation of industrial buildings. Proceedings of Plumee 2015, Alma Mater Publishing House. Available online: http://pubs.ub.ro/dwnl.php?id=PLUMEE201501V05S01A0009.
  4. Mark, S., Iscott, G.B., Donoviel, D.B., Leveton, L.B., Mahoney, E., Charles, J.B., and Siegel, B. (2020, June 02). The Impact of Sex and Gender on Adaptation to Space: Executive Summary, Available online: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4236030/.

Cited by

See all 9

Metadata

Authors
Kaczmarzyk, M., Starakiewicz, A., & Waśniowski, A.
Affiliations
  • Rzeszów University of Technology (PL)
  • LUNARES Mobile Research Station, Space Garden ltd., Pl. Wolnosci 13/2, 35-073 Rzeszow, Poland
Corresponding author
Kaczmarzyk, Marcin
Venue
Energies
Publisher
MDPI AG
Published
2020-06-20
Volume
13
Issue
12
Pages
3213
ISSN
1996-1073 (ISSN-L)
OpenAlex
W3036966097
Cited by
9
References
38
Citations by year
2025: 3 · 2023: 3 · 2022: 2 · 2021: 1
FWCI
0.90
Type
journal article
Language
en
Open access
Locations
  • Energies (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Space Exploration and Technology
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Aerospace Engineering › Spacecraft Design and Technology
Keywords
internal heat gains, lunar base, heat balance, waste heat, energy storage systems, lithium-ion batteries, photovoltaic power, life support systems, regenerative fuel cells, electrical equipment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Internal Heat Gains in a Lunar Base—A Contemporary Case Study. https://app.cochat.ai/papers/10.3390/en13123213
The paper
Kaczmarzyk, M., Starakiewicz, A., & Waśniowski, A. (2020). Internal Heat Gains in a Lunar Base—A Contemporary Case Study. Energies. https://doi.org/10.3390/en13123213

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.