How Multi-Criterion Optimized Control Methods Improve Effectiveness of Multi-Zone Building Heating System Upgrading
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper aims to develop multi-objective optimized control methods to improve the performance of retrofitting building heating systems in reducing consumed energy as well as providing comfortable temperature in a multi-zone building. While researchers evaluate various controllers in specific systems, providing a comprehensive controller for retrofitting the existing heating systems of multi-zone buildings is less investigated. A case study approach with a four-story residential building is simulated. The building energy consumption is modeled by EnergyPlus. The model is validated with energy data. Then, the building steam system model is upgraded, and in the other case, renewed by a hydronic system instead of a steam one. Three optimized controller groups are developed, including Model Predictive Controller (MPC), fuzzy controllers (Fuzzy Logic Controller (FLC) and an Optimized Fuzzy Sliding Mode Controller (OFSMC)), and optimized traditional ones. These controllers were applied to the upgraded steam and hydronic heating systems. The control methods affected the tuning of the boiler feed flow by regulating the condensing cycle and circulating the pump flow of the hydronic system. Accordingly, renewing the heating system improves energy efficiency by up to 29% by implementing a hydronic system instead of the steam one. The fuzzy controllers increased renewing effectiveness by providing comfortable temperatures and reducing building environmental footprints by up to 95% and 12%, respectively, compared with an on/off controller baseline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Model predictive control (MPC) is widely used in the field of commercial building energy efficiency due to its advantages of good control effect, strong robustness, and fast response speed [2][3][4].”
From Energy-Saving Control Method for Factory Mushroom Room Air Conditioning Based on MPC (2023) · cites this paper as [2]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory and applications of HVAC control systems – A review of model predictive control (MPC)
Afram, A., & Janabi-Sharifi, F. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.016 · Cited by 1,310
Energy management strategies in hybrid renewable energy systems: A review
Olatomiwa, L., Mekhilef, S., Ismail, M. S., & Moghavvemi, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.05.040 · Cited by 645
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Users Manual for TMY3 Data Sets (Revised)
Wilcox, S., & Marion, W. (2008) · doi:10.2172/928611 · Cited by 484
Ten Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Attia, S., Hamdy, M., O’Brien, W., & Carlucci, S. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.01.016 · Cited by 454
Halhoul Merabet, G., Essaaidi, M., Ben Haddou, M., Qolomany, B., Qadir, J., Anan, M., Al-Fuqaha, A., Abid, M. R., & Benhaddou, D. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110969 · Cited by 422
Li, Y., Tong, S., & Li, T. (2016) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2015.2486811 · Cited by 400
Advanced Sliding Mode Control for Mechanical Systems
Liu, J., & Wang, X. (2011) · Springer eBooks · doi:10.1007/978-3-642-20907-9 · Cited by 363
MPC-Based Appliance Scheduling for Residential Building Energy Management Controller
Chen, C., Wang, J., Heo, Y., & Kishore, S. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2265239 · Cited by 287
Research works printed but not linked: 2
- Grondzik, W.T., and Kwok, A.G. (2019). Mechanical and Electrical Equipment for Buildings, John Wiley & Sons.
- Perera, 2014, International journal of energy and environment Control of temperature and energy consumption in buildings-A review, Int. J. Energy Environ., 5, 2076
Cited by
Agouzoul, A., Simeu, E., & Tabaa, M. (2024) · Sustainability · doi:10.3390/su16072879 · Cited by 22
Energy-Saving Control Method for Factory Mushroom Room Air Conditioning Based on MPC
Wang, M., Zheng, W., Zhao, C., Chen, Y., Chen, C., & Zhang, X. (2023) · Energies · doi:10.3390/en16227623 · Cited by 8
Norouziasas, A., Esmaeilzadeh, A., Yin, H., Nord, N., & Hamdy, M. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116134 · Cited by 7
Self-citationEsmaeilzadeh, A., Deal, B. M., & Hamdy, M. (2026) · Energy Reports · doi:10.1016/j.egyr.2026.109049 · Cited by 3
Self-citationEsmaeilzadeh, A., & Hamdy, M. (2024) · IEEE International Conference on Smart Energy Grid Engineering (SEGE) · doi:10.1109/sege62220.2024.10739531 · Cited by 2
Self-citation
Metadata
- Authors
- Esmaeilzadeh, A., Deal, B., Yousefi-Koma, A., & Zakerzadeh, M. R.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Center of Advanced Systems and Technologies (CAST), School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 15614, Iran
- University of Tehran (IR)
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2022-11-18
- Volume
- 15
- Issue
- 22
- Pages
- 8675
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W4309740742
- Cited by
- 10
- References
- 46
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 2
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Iran National Science Foundation (4013238)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Keywords
- heating system retrofit, multi-objective control, model predictive control, fuzzy logic controller, hydronic heating, steam heating systems, building energy consumption, thermal comfort, residential buildings, EnergyPlus simulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How Multi-Criterion Optimized Control Methods Improve Effectiveness of Multi-Zone Building Heating System Upgrading. https://app.cochat.ai/papers/10.3390/en15228675
- The paper
- Esmaeilzadeh, A., Deal, B., Yousefi-Koma, A., & Zakerzadeh, M. R. (2022). How Multi-Criterion Optimized Control Methods Improve Effectiveness of Multi-Zone Building Heating System Upgrading. Energies. https://doi.org/10.3390/en15228675
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.