Immunohistochemical Evaluation of Peri-Implant Soft Tissues around Machined and Direct Metal Laser Sintered (DMLS) Healing Abutments in Humans
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Direct metal laser Sintering (DMLS) is an additive manufacturing technique that allows fabrication of dental implants and related components with a highly porous surface. To date, no human studies have investigated the soft tissue adhesion and presence of inflammatory infiltrate with porous DMLS healing abutments (HAs), nor have they compared these with the classic machined ones. Purpose: To evaluate the degree of cell adhesion (integrin expression) and the quantity/quality of inflammatory infiltrate, on HAs with different surfaces; full DMLS, full machined, and hybrid (half DMLS and half machined). Methods: Fifty implant patients were randomly assigned to receive one of these different Has: T1, full DMLS (11 subjects); T2, machined in the upper portion and DMLS in the lower one (10 subjects); T3, DMLS in the upper portion and machined in the lower one (19 subjects); T4, full machined (10 patients). Thirty days after placement, circular sections of soft tissues around HAs were retrieved for immunohistochemical evaluation. Results: With regard to the adhesion molecules, the samples showed different intensity of integrin expression, with a statistically significant difference (p < 0.001) between T1 and the other groups. All the samples were positive for the different clusters related to the inflammatory infiltrate (T lymphocytes, CD3; B lymphocytes, CD20; and macrophages, CD68), but a lower infiltrate was found in T1, with statistically significant differences (p < 0.001) among the groups. Conclusions: The HA surface seems to influence the degree of cell adhesion and the inflammatory infiltrate of the surrounding soft tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dental plaque as a biofilm and a microbial community—Implications for health and disease
Marsh, P. D. (2006) · BMC Oral Health · doi:10.1186/1472-6831-6-s1-s14 · Cited by 1,094
Dimensions and Relations of the Dentogingival Junction in Humans
Gargiulo, A. W., Wentz, F. M., & Orban, B. (1961) · The Journal of Periodontology · doi:10.1902/jop.1961.32.3.261 · Cited by 1,053
Cited by
Mangano, C., Bianchi, A., Mangano, F. G., Dana, J., Colombo, M., Solop, I., & Admakin, O. (2020) · 3D Printing in Medicine · doi:10.1186/s41205-019-0055-x · Cited by 119
Self-citationThe biological width around implant
Zheng, Z., Ao, X., Xie, P., Jiang, F., & Chen, W. (2021) · Journal of Prosthodontic Research · doi:10.2186/jpr.jpor_2019_356 · Cited by 84
Custom-made additively manufactured subperiosteal implant
STRAPPA, E. M., MEMÈ, L., CEREA, M., ROY, M., & BAMBINI, F. (2023) · Minerva Dental and Oral Science · doi:10.23736/s2724-6329.22.04640-x · Cited by 32
Metadata
- Authors
- Mangano, C., Mangano, F. G., Shibli, J. A., Roth, L. A., D’ Addazio, G., Piattelli, A., & Iezzi, G.
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2018-07-30
- Volume
- 15
- Issue
- 8
- Pages
- 1611
- ISSN
- 1660-4601 (ISSN-L)
- OpenAlex
- W2883018275
- Cited by
- 38
- References
- 2
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.