Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Building renovations can adversely affect building occupants through the release of biological contaminants, gases and particulates. In this study, the research aim was to monitor the air quality of a renovated building and assess the impact of sick building syndrome (SBS) on the occupants. Post occupancy monitoring of the building was carried out after two months occupancy for the following environmental parameters: airborne microflora using an air sampler (SAS super 180) and a hand-held monitoring device (Graywolf advance sense IQ-610) to measure total volatile organic compounds (TVOC), CO2, CO and temperature and relative humidity in each office environment. In addition, an online (Qualtrics) structured questionnaire was used to assess occupants’ perceptions of the indoor environment. Results of the airborne flora showed 833 cfu/m3 recovered on a Malt Extract Agar (MEA) plate in the morning and 1213 cfu/m3 in the afternoon. A similar result was noticed on a Plate Count Agar (PCA) plate during the morning period (731 cfu/m3) and afternoon (1358 cfu/m3). Results of TVOC monitored over one week showed that the first two days of monitoring had a high reading that peaked at 10,837 ppb and that the CO2 concentration during that period was 1163 ppm. Online questionnaire analysis indicates that a majority of the staff who took part in the survey experienced some form of health abnormality, including headache, shortness of breath, itchy eyes/ears, loss of concentration and so on, especially in the first few weeks of returning to the office. The results from the study indicate that a large proportion (41%) of the respondents experienced thermal discomfort as a result of varying room temperature during their working hours. A high number of female participants experienced some form of SBS as compared to their male counterparts. The study findings show a direct relationship between high airborne mold counts, TVOC and adverse staff health perception of the building. The study raised a number of opportunities for estate managers to improve building performance based on occupants’ preferences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The SAS air sampler was previously used for monitoring airborne microorganisms in various indoor and outdoor occupational and recreational environments [34,35].”
From Exposure Levels of Airborne Fungi, Bacteria, and Antibiotic Resistance Genes in Cotton Farms during Cotton Harvesting and Evaluations of N95 Respirators against These Bioaerosols (2023) · cites this paper as [34]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Literature survey on how different factors influence human comfort in indoor environments
Frontczak, M., & Wargocki, P. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.10.021 · Cited by 1,248 · cited 3×
“Poorly maintained indoor environments can increase time lost to illness and stress, and can reduce comfort and staff work pace, leading to a reduction in work output [4,5].”
BackgroundA review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843 · cited 1×
“Thermal comfort plays a significant role in the productivity of occupants of any indoor environment, and high degrees of thermal discomfort can result in loss of productivity [19].”
BackgroundThermal comfort and gender: a literature review
Karjalainen, S. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00747.x · Cited by 536 · cited 1×
“These studies reported similar findings where the female respondents reported less satisfaction around each variable considered [15,16].”
ResultGender differences in thermal comfort and use of thermostats in everyday thermal environments
Karjalainen, S. (2007) · Building and Environment · doi:10.1016/j.buildenv.2006.01.009 · Cited by 452 · cited 2×
“Recent studies by Kim et al. [2] and Karjalainen [7] have reported females as being more likely than males to report dissatisfaction of an indoor air environment and other sick building symptoms (SBS) such as fatigue, headache, irritated or dry eyes/nose/throat or skin symptoms.”
BackgroundIndoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
The medical effects of mold exposure
Bush, R. K., Portnoy, J. M., Saxon, A., Terr, A. I., & Wood, R. A. (2006) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.12.001 · Cited by 337
Gender differences in office occupant perception of indoor environmental quality (IEQ)
Kim, J., de Dear, R., Cândido, C., Zhang, H., & Arens, E. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.022 · Cited by 267 · cited 3×
“, nutritional differences, fitness, ethnicity and social class) may lead to a misrepresentation of SBS impact based on gender differentiation [2].”
BackgroundThermal comfort in offices in India: Behavioral adaptation and the effect of age and gender
Indraganti, M., Ooka, R., & Rijal, H. B. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.042 · Cited by 207 · cited 1×
“These studies reported similar findings where the female respondents reported less satisfaction around each variable considered [15,16].”
ResultIndoor air quality in public utility environments—a review
Śmiełowska, M., Marć, M., & Zabiegała, B. (2017) · Environmental Science and Pollution Research · doi:10.1007/s11356-017-8567-7 · Cited by 187
BRASCHE, S., BULLINGER, M., MORFELD, M., GEBHARDT, H. J., & BISCHOF, W. (2001) · Indoor Air · doi:10.1034/j.1600-0668.2001.110402.x · Cited by 151 · cited 1×
“However, from these few work done, the female gender has been reported to be an important factor in several SBS studies [6].”
BackgroundGola, M., Settimo, G., & Capolongo, S. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/8358306 · Cited by 120
A field study about gender and thermal comfort temperatures in office buildings
Maykot, J. K., Rupp, R. F., & Ghisi, E. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.033 · Cited by 119 · cited 1×
“Both physiological and metabolic rate differences have previously been reported as factors that contribute to different levels of SBS reported between genders [17,18].”
BackgroundComparison between male and female subjective estimates of thermal effects and sensations
BESHIR, M. Y., & Ramsey, J. D. (1981) · Applied Ergonomics · doi:10.1016/0003-6870(81)90091-0 · Cited by 118 · cited 1×
“Both physiological and metabolic rate differences have previously been reported as factors that contribute to different levels of SBS reported between genders [17,18].”
BackgroundHuman health and thermal comfort of office workers in Singapore
Chen, A., & Chang, V. W.-C. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.07.004 · Cited by 107 · cited 1×
“It is worth noting that urban environments comprise high building densities, of which sick building syndrome (SBS) symptoms and levels of thermal comfort are important concerns from both building operation and occupant health/productivity points of view [12].”
BackgroundPark, J.-H., Schleiff, P. L., Attfield, M. D., Cox‐Ganser, J. M., & Kreiss, K. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00291.x · Cited by 101
Haghighat, F., & Donnini, G. (1999) · Building and Environment · doi:10.1016/s0360-1323(98)00034-1 · Cited by 100 · cited 1×
“Despite efforts that have been made to improve air quality and ventilation standards in buildings, occupants’ satisfaction level also need further investigation, as ventilation standards do not necessarily ensure a reasonable level of occupant satisfaction [5,9].”
BackgroundIndoor Temperature, Productivity, and Fatigue in Office Tasks
Tanabe, S.-I., Nishihara, N., & Haneda, M. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390975 · Cited by 98
Medrela-Kuder, E. (2003) · International Biodeterioration & Biodegradation · doi:10.1016/s0964-8305(02)00167-1 · Cited by 91 · cited 1×
“The external environment was the chief source of these molds found in the indoor air, and seasonal variations and climatic conditions contribute to increases in the number but also the types of fungal spores present in the air [26,27].”
BackgroundKreja, L., & Seidel, H. (2002) · Chemosphere · doi:10.1016/s0045-6535(02)00159-5 · Cited by 58
Genotoxicity of Microbial Volatile Organic Compounds
Nakajima, D., Ishii, R., Kageyama, S., Yoshiki, O. N. J. I., Mineki, S., MOROOKA, N., Takatori, K., & Goto, S. (2006) · Eisei kagaku · doi:10.1248/jhs.52.148 · Cited by 46
Psychosocial factors and gender as predictors of symptoms associated with sick building syndrome
Kinman, G., & Griffin, M. (2008) · Stress and Health · doi:10.1002/smi.1175 · Cited by 34 · cited 1×
“It has further been suggested that the reason why women report more symptoms related to SBS than men is that they tend to work in less favorable physical and psychosocial conditions than men [8].”
BackgroundPsychosocial Factors and the "Sick Building-Syndrome". A case-referent study
Eriksson, N., Höög, J., Stenberg, B., & Sundell, J. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-2-00006.x · Cited by 30
Cox‐Ganser, J. M. (2015) · Clinical & Experimental Allergy · doi:10.1111/cea.12601 · Cited by 30
Gola, M., Settimo, G., & Capolongo, S. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16224388 · Cited by 29
Moda, H. M., & King, D. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16183284 · Cited by 17 · cited 4×
“At high concentrations, many of these TVOCs are potent narcotics and can depress the central nervous system [5,25], and exposure to these compounds can lead to irritation of the eyes and respiratory tracts, in addition to causing sensitization reactions involving the eyes, skin and lungs.”
BackgroundMethodInfluentialSelf-citationThe Impact of Sick Building Syndrome on Call Centre Agents’ Effectiveness
Oodith, D., & Parumasur, S. B. (2012) · Journal of Economics and Behavioral Studies · doi:10.22610/jebs.v4i9.355 · Cited by 10
Research works printed but not linked: 3
- Humphreys, M.A., and Nicol, J.F. (2020, February 26). Self-Assessed Productivity and the Office Environment: Monthly Surveys in Five European Countries. ASHRAE Transactions. Available online: http://www.thefreelibrary.com/_/print/PrintArticle.aspx?id=164927243.
- Musa, H.M., Aidoo, K.A., and Hunter, C.A. (2009, January 13–17). The Occurrence of Aflatoxins, Mutagenicity and Cytotoxicity Nature of Dust Samples from a Converted Library Block into Office Space. Proceedings of the Paper Presented at the 9th International Conference and Exhibition of Healthy Buildings, Syracuse, NY, USA.
- Musa, H.M., Hunter, C.A., and Aidoo, K.A. (2009, January 13–17). Cytotoxicity and MVOCs Released by Stachybotrys Chartarum Isolated from Water Damaged Residential Buildings in Glasgow. Proceedings of the Paper Presented at the 9th International Conference and Exhibition of Healthy Buildings, Syracuse, NY, USA.
Cited by
Awada, M., Becerik-Gerber, B., White, E., Hoque, S., O’Neill, Z. D., Pedrielli, G., Wen, J., & Wu, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108440 · Cited by 118
Niza, I. L., de Souza, M. P., da Luz, I. M., & Broday, E. E. (2023) · Indoor and Built Environment · doi:10.1177/1420326x231191079 · Cited by 93
Post-Occupancy Evaluation’s (POE) Applications for Improving Indoor Environment Quality (IEQ)
Lolli, F., Marinello, S., Coruzzolo, A. M., & Butturi, M. A. (2022) · Toxics · doi:10.3390/toxics10100626 · Cited by 57
Dam-Krogh, E. P., Rupp, R. F., Clausen, G., & Toftum, J. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.108911 · Cited by 46
Aziz, N., Adman, M. A., Suhaimi, N. S., Misbari, S., Alias, A. R., Aziz, A. A., Lee, L. F., & Khan, M. M. H. (2023) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1140/1/012007 · Cited by 30
“Nevertheless, headache, fatigue, difficulty concentrating or breathing, feeling sleepy, and chest tightness were also some of the general symptoms reported by the office staff [29,41,44].”
BackgroundInfluential
Metadata
- Authors
- Fahad Alomirah, H., & Moda, H. M.
- Affiliations
- College of Health Sciences, Shawaik, P.O. Box 1983, Safat 13020, Kuwait
- Manchester Metropolitan University (GB)
- Corresponding author
- Moda, Haruna Musa
- ORCID
- Moda, Haruna Musa
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2020-03-17
- Volume
- 17
- Issue
- 6
- Pages
- 1972
- ISSN
- 1660-4601 (ISSN-L)
- PMC
- PMC7143121
- OpenAlex
- W3011926615
- Cited by
- 34
- References
- 28
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 5 · 2023: 8 · 2022: 5 · 2021: 4 · 2020: 1
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- International Journal of Environmental Research and Public Health (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- e-space (Manchester Metropolitan University) (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Architecture › Facilities and Workplace Management
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- indoor air quality, building renovation, sick building syndrome, airborne microorganisms, airborne mold, total volatile organic compounds, carbon dioxide, carbon monoxide, thermal discomfort, office buildings
- MeSH terms
- England, Female, Fungi, Humans, Male, Perception, Temperature, Air Pollution, Indoor, Sick Building Syndrome, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.