Sustainability of Heating, Ventilation and Air-Conditioning (HVAC) Systems in Buildings—An Overview
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
Increasing demand on heating, ventilation, and air-conditioning (HVAC) systems and their importance, as the respiratory system of buildings, in developing and spreading various microbial contaminations and diseases with their huge global energy consumption share have forced researchers, industries, and policymakers to focus on improving the sustainability of HVAC systems. Understanding and considering various parameters related to the sustainability of new and existing HVAC systems as the respiratory system of buildings are vital to providing healthy, energy-efficient, and economical options for various building types. However, the greatest opportunities for improving the sustainability of HVAC systems exist at the design stage of new facilities and the retrofitting of existing equipment. Considering the high available percentage of existing HVAC systems globally reveals the importance of their retrofitting. The attempt has been made to gather all important parameters that affect decision-making to select the optimum HVAC system development considerations among the various opportunities that are available for sustainability improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“However, these systems account for 40–60% of energy usage in buildings [1] or 15% of the world’s total energy consumption (Rafique 2018).”
BackgroundExisting building retrofits: Methodology and state-of-the-art
Ma, Z., Cooper, P., Daly, D., & Ledo, L. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.08.018 · Cited by 1,234
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Progress and Expectation of Atmospheric Water Harvesting
Tu, Y., Wang, R., Zhang, Y., & Wang, J. (2018) · Joule · doi:10.1016/j.joule.2018.07.015 · Cited by 762 · cited 1×
“HVAC systems are considered air–water harvesting systems that liquefy the water vapor available in the air as they condensate; they are also a potential water source [92].”
BackgroundTowards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review
Chenari, B., Dias Carrilho, J., & Gameiro da Silva, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.074 · Cited by 515 · cited 1×
“The study showed that ventilation was interrelated with various factors, such as indoor and outdoor conditions, building characteristics and application, and occupants’ behavior [65].”
BackgroundA review of air filtration technologies for sustainable and healthy building ventilation
Liu, G., Xiao, M., Zhang, X., Gál, C., Chen, X., Liu, L., Pan, S., Wu, J., Tang, L., & Clements-Croome, D. J. (2017) · Sustainable Cities and Society · doi:10.1016/j.scs.2017.04.011 · Cited by 471
Life cycle assessment (LCA) of building refurbishment: A literature review
Vilches, A., Garcia-Martinez, A., & Sanchez-Montañes, B. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2016.11.042 · Cited by 449 · cited 1×
“The fact that more than 25% of existing buildings in Europe are more than 70 years old [110,111], 60% of residential building in the US are more than 30 years old [112], and a high percentage of developing countries are currently using low sustainability concepts suggests the importance of considering their retrofitti…”
BackgroundModeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411 · cited 1×
“advantages, disadvantages, and outcomes of different modeling techniques to find the best option for their application [66,75,77].”
BackgroundReview on heat recovery technologies for building applications
Mardiana-Idayu, A., & Riffat, S. B. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.09.026 · Cited by 352
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Ten questions concerning green buildings and indoor air quality
Steinemann, A., Wargocki, P., & Rismanchi, B. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.010 · Cited by 268 · cited 1×
“Spending more than 80% of peoples’ time indoors reveals the importance of IAQ on the health and comfort of occupants [78].”
BackgroundA comprehensive study of geothermal heating and cooling systems
Soltani, M., M. Kashkooli, F., Dehghani-Sanij, A. R., Kazemi, A. R., Bordbar, N., Farshchi, M. J., Elmi, M., Gharali, K., & B. Dusseault, M. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.09.036 · Cited by 257 · cited 1×
“Desiccant heating, cooling, and ventilation [12–15]; evaporative passive cooling [16,17]; solar heating and cooling systems [18,19]; geothermal heating and cooling systems [20]; and biomass heating and cooling technologies [21,22] are examples of renewable technologies that are used in HVAC systems in buildings.”
BackgroundEnergy and environmental benefits in public buildings as a result of retrofit actions
Ardente, F., Beccali, M., Cellura, M., & Mistretta, M. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.09.022 · Cited by 257 · cited 1×
“The fact that more than 25% of existing buildings in Europe are more than 70 years old [110,111], 60% of residential building in the US are more than 30 years old [112], and a high percentage of developing countries are currently using low sustainability concepts suggests the importance of considering their retrofitti…”
BackgroundA review of HVAC systems requirements in building energy regulations
Pérez-Lombard, L., Ortiz, J., Coronel, J. F., & Maestre, I. R. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.10.025 · Cited by 256
A review on polymer heat exchangers for HVAC&R applications
T'Joen, C., Park, Y., Wang, Q., Sommers, A., Han, X., & Jacobi, A. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.008 · Cited by 246 · cited 1×
“The use of liquid-to-air membrane energy exchangers [46,47], porous metal foam heat exchangers [48], nanofluid as heat transfer fluid [49], phase change material as heat transfer media [50–53], membrane heat exchanger [54–56], and polymer heat exchangers [57,58] affect the energy consumption and recovery and sustainab…”
BackgroundHeat transfer and pressure drop performance of Nanofluid: A state-of- the-art review
Awais, M., Ullah, N., Ahmad, J., Sikandar, F., Ehsan, M. M., Salehin, S., & Bhuiyan, A. A. (2021) · International Journal of Thermofluids · doi:10.1016/j.ijft.2021.100065 · Cited by 229 · cited 1×
“The use of liquid-to-air membrane energy exchangers [46,47], porous metal foam heat exchangers [48], nanofluid as heat transfer fluid [49], phase change material as heat transfer media [50–53], membrane heat exchanger [54–56], and polymer heat exchangers [57,58] affect the energy consumption and recovery and sustainab…”
BackgroundAdaptive-predictive control strategy for HVAC systems in smart buildings – A review
Gholamzadehmir, M., Del Pero, C., Buffa, S., Fedrizzi, R., & Aste, N. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102480 · Cited by 226 · cited 2×
“The use of these smart technologies in buildings and HVAC systems could reduce energy and cost remarkably [7,73] (Figure 2).”
BackgroundMa, N., Aviv, D., Guo, H., & Braham, W. W. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110436 · Cited by 217 · cited 1×
“advantages, disadvantages, and outcomes of different modeling techniques to find the best option for their application [66,75,77].”
BackgroundAn optimization framework for building energy retrofits decision-making
Jafari, A., & Valentin, V. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.01.020 · Cited by 200 · cited 1×
“However, optimum decision making that considers various important parameters, such as energy modeling and assessment, retrofit designs, cost, and risk assessment, is crucial [115,116].”
BackgroundA comprehensive review of heat recovery systems for building applications
Cuce, P. M., & Riffat, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.03.087 · Cited by 192
Lavagna, M., Baldassarri, C., Campioli, A., Giorgi, S., Dalla Valle, A., Castellani, V., & Sala, S. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.09.008 · Cited by 185 · cited 1×
“The fact that more than 25% of existing buildings in Europe are more than 70 years old [110,111], 60% of residential building in the US are more than 30 years old [112], and a high percentage of developing countries are currently using low sustainability concepts suggests the importance of considering their retrofitti…”
BackgroundMembrane heat exchanger in HVAC energy recovery systems, systems energy analysis
Nasif, M. S., Al‐Waked, R., Morrison, G. L., & Behnia, M. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.020 · Cited by 160
A simplified modeling of cooling coils for control and optimization of HVAC systems
Wang, Y.-W., Cai, W., Soh, Y. C., Li, S., Lu, L., & Xie, L. (2004) · Energy Conversion and Management · doi:10.1016/j.enconman.2003.12.024 · Cited by 158 · cited 1×
“cooling coils [31], and ducts and fans [27,32], can reduce the energy consumption of such systems while optimizing their performance [13].”
BackgroundNath, R. K., Zain, M. F. M., & Jamil, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.05.018 · Cited by 156 · cited 1×
“Photocatalysis, plasma, UV, microwave sterilization, and physical adsorption are among the common air purification technologies that are combined with HVAC systems to control indoor microbial contaminations [82,90].”
BackgroundLiu, Z., Ma, S., Cao, G., Meng, C., & He, B. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.050 · Cited by 148 · cited 8×
“Photocatalysis, plasma, UV, microwave sterilization, and physical adsorption are among the common air purification technologies that are combined with HVAC systems to control indoor microbial contaminations [82,90].”
BackgroundMethodInfluentialPang, Z., Chen, Y., Zhang, J., O’Neill, Z. D., Cheng, H., & Dong, B. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115727 · Cited by 145 · cited 1×
“Meanwhile, new integrated designs that implant programmed control systems are very efficient in developing energy-efficient HVAC systems in buildings [33,72,73].”
BackgroundReview of phase change emulsions (PCMEs) and their applications in HVAC systems
Shao, J., Darkwa, J., & Kokogiannakis, G. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.03.003 · Cited by 136
Life Cycle Sustainability Assessment in Building Energy Retrofitting; A Review
Toosi, H. A., Lavagna, M., Leonforte, F., Pero, C. D., & Aste, N. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102248 · Cited by 125 · cited 2×
“[113] reviewed the life cycle sustainability assessment of studies conducted for building energy retrofitting to determine the life cycle environmental impacts, economic aspects, and the social dimensions of a product, service, or process.”
BackgroundGraphene Based Aerogels: Fundamentals and Applications as Supercapacitors
Pottathara, Y. B., Tiyyagura, H. R., Ahmad, Z., & Sadasivuni, K. K. (2020) · Journal of Energy Storage · doi:10.1016/j.est.2020.101549 · Cited by 119
Potential use of evaporator coils for water extraction in hot and humid areas
Habeebullah, B. A. (2009) · Desalination · doi:10.1016/j.desal.2008.01.025 · Cited by 117
Integrated HVAC and DHW production systems for Zero Energy Buildings
Fabrizio, E., Seguro, F., & Filippi, M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.193 · Cited by 112
Air-conditioning condensate recovery and applications—Current developments and challenges ahead
Algarni, S., Saleel, C. A., & Mujeebu, M. A. (2017) · Sustainable Cities and Society · doi:10.1016/j.scs.2017.11.032 · Cited by 111 · cited 3×
“[94] reviewed various condensate recovery systems in HVAC systems, the potential application of the collected water, and the quality characteristics of the condensate water (Figure 7).”
BackgroundSun, W., Zhang, Y., Ling, Z., Fang, X., & Zhang, Z. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109806 · Cited by 109
Ma, Z., Ren, H., & Lin, W. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.118158 · Cited by 105 · cited 2×
“Furthermore, sustainability considerations and innovations in HVAC systems are necessary to provide a remarkable, healthy, productive, and sustainable built environment for occupants while reducing energy consumption and costs [2].”
BackgroundSolutions for enhancement of energy and exergy efficiencies in air handling units
Liu, W., Kalbasi, R., & Afrand, M. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.120565 · Cited by 104 · cited 1×
“Air-to-air heat exchangers [37] and heat pipe heat exchangers (HPHE) with different forms and designs can be used as heat recovery equipment for the air quality improvement in HVAC systems [33,38–45].”
MethodKuruneru, S. T. W., Vafai, K., Sauret, E., & Gu, Y. (2020) · Chemical Engineering Science · doi:10.1016/j.ces.2020.115968 · Cited by 102 · cited 1×
“The use of liquid-to-air membrane energy exchangers [46,47], porous metal foam heat exchangers [48], nanofluid as heat transfer fluid [49], phase change material as heat transfer media [50–53], membrane heat exchanger [54–56], and polymer heat exchangers [57,58] affect the energy consumption and recovery and sustainab…”
BackgroundShamim, J. A., Hsu, W., Paul, S., Yu, L., & Daiguji, H. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110456 · Cited by 96 · cited 1×
“Modified and improved designs for various components in HVAC systems, such as dampers dampers [25,26], filters [27,28], humidifier, dehumidifier [29,30], heating and”
BackgroundBiomass-fired combined cooling, heating and power for small scale applications – A review
Wegener, M., Malmquist, A., Isalgué, A., & Martin, A. R. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.07.044 · Cited by 91 · cited 1×
“Desiccant heating, cooling, and ventilation [12–15]; evaporative passive cooling [16,17]; solar heating and cooling systems [18,19]; geothermal heating and cooling systems [20]; and biomass heating and cooling technologies [21,22] are examples of renewable technologies that are used in HVAC systems in buildings.”
BackgroundBaç, U., Alaloosi, K. A. M. S., & Turhan, C. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102153 · Cited by 86 · cited 3×
“Moreover, the decision makers could use decision-making methods to develop optimum plans that consider the various advantages and disadvantages and the potential risk of each option [75,118,119].”
BackgroundMethodAbdel-Salam, M. R. H., Fauchoux, M. T., Ge, G., BESANT, R. W., & Simonson, C. J. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.004 · Cited by 84 · cited 1×
“The use of liquid-to-air membrane energy exchangers [46,47], porous metal foam heat exchangers [48], nanofluid as heat transfer fluid [49], phase change material as heat transfer media [50–53], membrane heat exchanger [54–56], and polymer heat exchangers [57,58] affect the energy consumption and recovery and sustainab…”
BackgroundStopps, H., Huchuk, B., Touchie, M. F., & O’Brien, W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107369 · Cited by 82 · cited 2×
“The use of these smart technologies in buildings and HVAC systems could reduce energy and cost remarkably [7,73] (Figure 2).”
BackgroundPotential and practical management of hybrid ventilation in buildings
Gomis, L. L., Fiorentini, M., & Daly, D. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110597 · Cited by 78 · cited 1×
“The effective management of mixed-mode (MM) buildings, which utilize natural and mechanical ventilation systems (hybrid), reduces the energy consumption of HVAC systems in a building; however, the reduction percentage depends on the climate, building type, and evaluation assumptions [68].”
BackgroundEnergy usage reduction in an air handling unit by incorporating two heat recovery units
Goldanlou, A. S., Kalbasi, R., & Afrand, M. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101545 · Cited by 76 · cited 1×
“[36] developed an air handling unit design equipped with primary and secondary heat recovery units and could increase the efficiency by 43.”
MethodEnergy Retrofit in European Building Portfolios: A Review of Five Key Aspects
Ruggeri, A. G., Gabrielli, L., & Scarpa, M. (2020) · Sustainability · doi:10.3390/su12187465 · Cited by 75 · cited 1×
“However, optimum decision making that considers various important parameters, such as energy modeling and assessment, retrofit designs, cost, and risk assessment, is crucial [115,116].”
BackgroundAbu‐Hamdeh, N. H., Melaibari, A. A., Alquthami, T., Khoshaim, A. B., Oztop, H. F., & Karimipour, A. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2020.100969 · Cited by 74
Nariman, A., Kalbasi, R., & Rostami, S. (2020) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-020-10068-4 · Cited by 71
Sukarno, R., Putra, N. S. D., Hakim, I. I., Rachman, F. F., & Mahlia, T. M. I. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.102116 · Cited by 63 · cited 2×
“Meanwhile, new integrated designs that implant programmed control systems are very efficient in developing energy-efficient HVAC systems in buildings [33,72,73].”
BackgroundShi, H., & Chen, Q. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101869 · Cited by 58 · cited 1×
“[70] investigated a well-validated building simulation model to compare the performance of 12 existing HVAC system strategies in decreasing energy usage, peak demand, and energy cost for decision making in the real world.”
Kim, D. D., & Suh, H.-S. (2021) · Energy Sustainable Development/Energy for sustainable development · doi:10.1016/j.esd.2021.01.001 · Cited by 55
Research and applications of ultrasound in HVAC field: A review
Yao, Y. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.222 · Cited by 49
Touchaei, A. G., Hosseini, M., & Akbari, H. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.10.018 · Cited by 49 · cited 1×
“Despite the availability of various methods that can be used in building design and retrofitting to improve the HVAC system performance [5,6], this paper only studies the parameters that directly deal with HVAC sustainability improvement.”
MethodKey factors of desiccant-based cooling systems: Materials
Asim, N., Amin, M. H., Alghoul, M. A., Badiei, M., Mohammad, M., Gasaymeh, S. S., Amin, N., & Sopian, K. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.113946 · Cited by 44
Self-citationGhimire, S. R., Johnston, J. M., Garland, J. L., Edelen, A. N., Ma, X. C., & Jahne, M. A. (2019) · Resources Conservation and Recycling · doi:10.1016/j.resconrec.2019.01.043 · Cited by 44 · cited 1×
“rainwater and condensate recovery are sustainable options for meeting the water demands in urban buildings [104,105].”
BackgroundBest Practices on HVAC Design to Minimize the Risk of COVID-19 Infection within Indoor Environments
Santos, A. F., Gaspar, P. D., Hamandosh, A., de Aguiar, E. B., Filho, A. C. G., & de Souza, H. J. L. (2020) · Brazilian Archives of Biology and Technology · doi:10.1590/1678-4324-2020200335 · Cited by 43 · cited 1×
“[87] studied various strategies to minimize the risk of COVID-19 infection within the indoor environment through an HVAC system design.”
BackgroundExperimental analysis of a multistage direct-indirect evaporative cooler using a straight heat pipe
Fikri, B., Sofia, E., & Putra, N. S. D. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115133 · Cited by 39
Koç, A., Yağlı, H., Bilgiç, H. H., Koç, Y., & Özdemir, A. (2020) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2020.100787 · Cited by 38
Feng, W., Wei, Z., Sun, G., Zhou, Y., Zang, H., & Chen, S. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106535 · Cited by 36 · cited 1×
“Moreover, the decision makers could use decision-making methods to develop optimum plans that consider the various advantages and disadvantages and the potential risk of each option [75,118,119].”
MethodArden, S., Morelli, B., Cashman, S. A., Ma, X. C., Jahne, M. A., & Garland, J. L. (2020) · Water Research · doi:10.1016/j.watres.2020.116635 · Cited by 33 · cited 1×
“rainwater and condensate recovery are sustainable options for meeting the water demands in urban buildings [104,105].”
BackgroundAbdel-Salam, M. R. H., BESANT, R. W., & Simonson, C. J. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.09.024 · Cited by 32 · cited 1×
“The use of liquid-to-air membrane energy exchangers [46,47], porous metal foam heat exchangers [48], nanofluid as heat transfer fluid [49], phase change material as heat transfer media [50–53], membrane heat exchanger [54–56], and polymer heat exchangers [57,58] affect the energy consumption and recovery and sustainab…”
BackgroundSu, Y. L. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101954 · Cited by 31 · cited 6×
“Figure 4 presents the energy flow charts between the supply side of smart energy system (SES) categories and the demand side in the SBE [74].”
BackgroundMethodInfluentialInvestigating energy saving potential in a big shopping center through ventilation control
Curto, D., Franzitta, V., Longo, S., Montana, F., & Sanseverino, E. R. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101525 · Cited by 31 · cited 2×
“Heat recovery systems: various heat recovery systems could be used in HVAC systems to reduce energy consumption [67].”
BackgroundMethodWang, Z., Li, H., Zhang, X. F., Wang, L., Du, S., & Fang, C. (2020) · Renewable Energy · doi:10.1016/j.renene.2020.04.108 · Cited by 28 · cited 1×
“Desiccant heating, cooling, and ventilation [12–15]; evaporative passive cooling [16,17]; solar heating and cooling systems [18,19]; geothermal heating and cooling systems [20]; and biomass heating and cooling technologies [21,22] are examples of renewable technologies that are used in HVAC systems in buildings.”
BackgroundHigh performance finned-tube heat exchangers based on filled polymer
Jabbour, J., Russeil, S., Mobtil, M., Bougeard, D., Lacrampe, M., & Krawczak, P. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.04.036 · Cited by 26 · cited 1×
“The use of liquid-to-air membrane energy exchangers [46,47], porous metal foam heat exchangers [48], nanofluid as heat transfer fluid [49], phase change material as heat transfer media [50–53], membrane heat exchanger [54–56], and polymer heat exchangers [57,58] affect the energy consumption and recovery and sustainab…”
BackgroundThermal performance of a novel ultrasonic evaporator based on machine learning algorithms
Song, J., Tian, W., Xu, X., Wang, Y., & Li, Z. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.11.083 · Cited by 21
Experimental study of an ultrasonic mist generator as an evaporative cooler
Martínez, P. M., Ramírez, J. R., Martín-Melero, I., & Miralles, M. L. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116057 · Cited by 20
Albdoor, A. K., Ma, Z., Cooper, P., Al‐Ghazzawi, F., Liu, J., Richardson, C., & Wagner, P. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.126157 · Cited by 19
Cobo-Golpe, M., Ramil, M., Cela, R., & Rodríguez, I. (2020) · Chemosphere · doi:10.1016/j.chemosphere.2020.126346 · Cited by 14
Assessing the impact of filtration systems in indoor environments with effectiveness
Li, T., & Siegel, J. A. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107389 · Cited by 13 · cited 1×
“However, the influence of various parameters on the performance of these technologies must be considered [89].”
BackgroundEnergy and economic analysis of model-based air dampers strategies on a VAV system
Kialashaki, Y. (2018) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-018-1863-z · Cited by 11 · cited 1×
“Modified and improved designs for various components in HVAC systems, such as dampers dampers [25,26], filters [27,28], humidifier, dehumidifier [29,30], heating and”
BackgroundIndoor air condensate as a novel matrix for monitoring inhalable organic contaminants
Roll, I. B., Halden, R. U., & Pycke, B. F. G. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.01.043 · Cited by 8
Cited by
Energy-saving control method for air conditioning in mushroom room based on a simplified PINN model
Kong, X., Wang, M., Li, Z., & Zheng, W. (2026) · Energy Reports · doi:10.1016/j.egyr.2025.108970
Metadata
- Authors
- Asim, N., Badiei, M., Mohammad, M., Razali, H., Rajabi, A., Chin Haw, L., & Jameelah Ghazali, M.
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2022-01-17
- Volume
- 19
- Issue
- 2
- Pages
- 1016
- ISSN
- 1660-4601 (ISSN-L)
- OpenAlex
- W4205771352
- Cited by
- 180
- References
- 70
- FWCI
- 13.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.