The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
CA 19-9 Pancreatic Tumor Marker Fluorescence Immunosensing Detection via Immobilized Carbon Quantum Dots Conjugated Gold Nanocomposite
Open accessAbstract
The clinical detection of carbohydrate antigen 19-9 (CA 19-9), a tumor marker in biological samples, improves and facilitates the rapid screening and diagnosis of pancreatic cancer. A simple, low cost, fast, and green synthesis method to prepare a viable carbon quantum dots/gold (CQDs/Au) nanocomposite fluorescence immunosensing solution for the detection of CA 19-9 was reported. The present method is conducted by preparing glucose-derived CQDs using a microwave-assisted method. CQDs were employed as reducing and stabilizing agents for the preparation of a CQDs/Au nanocomposite. The immobilized anti-CA 19-9-labeled horseradish peroxidase enzyme (Ab–HRP) was anchored to the surface of a CQDs/Au nanocomposite by a peptide interaction between the carboxylic and amine active groups. The CA 19-9 antigen was trapped by another monoclonal antibody that was coated on the surface of microtiter wells. The formed sandwich capping antibody–antigen–antibody enzyme complex had tunable fluorescence properties that were detected under excitation and emission wavelengths of 420 and 530 nm. The increase in fluorescence intensities of the immunoassay sensing solution was proportional to the CA 19-9 antigen concentration in the linear range of 0.01–350 U mL−1 and had a lower detection limit of 0.007 U mL−1. The proposed CQDs/Au nanocomposite immunoassay method provides a promising tool for detecting CA 19-9 in human serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2017) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21387 · Cited by 14,712
Cited by
Recent Developments of Carbon Dots in Biosensing: A Review
Ji, C., Zhou, Y., Leblanc, R. M., & Peng, Z. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01556 · Cited by 461
A review of carbon quantum dots and their applications in wastewater treatment
Rani, U. A., Ng, L. Y., Ng, C. Y., & Mahmoudi, E. (2020) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102124 · Cited by 417
Green synthesis of carbon quantum dots and their environmental applications
Manikandan, V., & Lee, N. Y. (2022) · Environmental Research · doi:10.1016/j.envres.2022.113283 · Cited by 336
Diagnostic biosensors in medicine – A review
Metkar, S. K., & Girigoswami, K. (2019) · Biocatalysis and Agricultural Biotechnology · doi:10.1016/j.bcab.2018.11.029 · Cited by 304
Metadata
- Authors
- Alarfaj, N., El-Tohamy, M., & Oraby, H.
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2018-04-11
- Volume
- 19
- Issue
- 4
- Pages
- 1162
- ISSN
- 1422-0067 (ISSN-L)
- OpenAlex
- W2798163080
- Cited by
- 190
- References
- 1
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CA 19-9 Pancreatic Tumor Marker Fluorescence Immunosensing Detection via Immobilized Carbon Quantum Dots Conjugated Gold Nanocomposite. https://app.cochat.ai/papers/10.3390/ijms19041162
- The paper
- Alarfaj, N., El-Tohamy, M., & Oraby, H. (2018). CA 19-9 Pancreatic Tumor Marker Fluorescence Immunosensing Detection via Immobilized Carbon Quantum Dots Conjugated Gold Nanocomposite. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms19041162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.