CoChat

Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies

Open access
Kim, Yuna, Kim, Hyun-Il, Park, Geun Seok, Kim, Seo Young, Choi, Sang-Il, Lee, Seong Jae · 2021 · Journal of Clinical Medicine

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Computer-assisted analysis is expected to improve the reliability of videofluoroscopic swallowing studies (VFSSs), but its usefulness is limited. Previously, we proposed a deep learning model that can detect laryngeal penetration or aspiration fully automatically in VFSS video images, but the evidence for its reliability was insufficient. This study aims to compare the intra- and inter-rater reliability of the computer model and human raters. The test dataset consisted of 173 video files from which the existence of laryngeal penetration or aspiration was judged by the computer and three physicians in two sessions separated by a one-month interval. Intra- and inter-rater reliability were calculated using Cohen’s kappa coefficient, the positive reliability ratio (PRR) and the negative reliability ratio (NRR). Intrarater reliability was almost perfect for the computer and two experienced physicians. Interrater reliability was moderate to substantial between the model and each human rater and between the human raters. The average PRR and NRR between the model and the human raters were similar to those between the human raters. The results demonstrate that the deep learning model can detect laryngeal penetration or aspiration from VFSS video as reliably as human examiners.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jcm10122681

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The same deep learning model we proposed in our previous study [20] is used in this study. After normalization of the input images, a dynamic ROI is defined with reference to the cervical spinal column segmented by U-net. The presence of laryngeal penetration or aspiration in the ROI can be identified by the Xception module.
Figure 1 The same deep learning model we proposed in our previous study [20] is used in this study. After normalization of the input images, a dynamic ROI is defined with reference to the cervical spinal column segmented by U-net. The presence of laryngeal penetration or aspiration in the ROI can be identified by the Xception module.CC BY · PubMed Central
Figure 2 Example output of the deep learning model represented as histograms: (A) No laryngeal penetration or aspiration was detected in any frame of the video. (B) Laryngeal penetration or aspiration occurred in approximately the 100th to 115th frames and the 180th to 200th frames of the video.
Figure 2 Example output of the deep learning model represented as histograms: (A) No laryngeal penetration or aspiration was detected in any frame of the video. (B) Laryngeal penetration or aspiration occurred in approximately the 100th to 115th frames and the 180th to 200th frames of the video.CC BY · PubMed Central
Figure 3 PRR and NRR values averaged between human raters and between machine and human raters.
Figure 3 PRR and NRR values averaged between human raters and between machine and human raters.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 12

Metadata

Authors
Kim, Y., Kim, H.-I., Park, G. S., Kim, S. Y., Choi, S.-I., & Lee, S. J.
Affiliations
  • Dankook University Hospital (KR)
  • Dankook University (KR)
Corresponding author
  • Choi, Sang-Il
  • Lee, Seong Jae
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2021-06-18
Volume
10
Issue
12
Pages
2681
ISSN
2077-0383 (ISSN-L)
OpenAlex
W3173183426
Cited by
12
References
29
Citations by year
2026: 1 · 2025: 4 · 2024: 3 · 2023: 3 · 2022: 1
FWCI
2.17
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Research Foundation of Korea (2021R1A2B5B01001412, 2018R1D1A3B07049300)
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
  • Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
Keywords
laryngeal penetration, aspiration, videofluoroscopic swallowing study, deep learning, computer-aided analysis, inter-rater reliability, intra-rater reliability, dysphagia, human raters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies. https://app.cochat.ai/papers/10.3390/jcm10122681
The paper
Kim, Y., Kim, H.-I., Park, G. S., Kim, S. Y., Choi, S.-I., & Lee, S. J. (2021). Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies. Journal of Clinical Medicine. https://doi.org/10.3390/jcm10122681

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.