Application of FTIR Method for the Assessment of Immobilization of Active Substances in the Matrix of Biomedical Materials
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Background: The purpose of the study was to demonstrate the usefulness of the Fourier transform infrared spectroscopy (FTIR) method for the evaluation of the modification process of biomaterials with the participation of active substances. Methods: Modified catheter samples were prepared by activating the matrix with an acid, iodine, or bromine, and then immobilizing the active molecules. To carry out the modification process, the Fourier transform infrared-attenuated total reflectance (FTIR-ATR) method was used. Results: FTIR analysis indicated the presence of the immobilized substances in the catheter matrix and site-specific reactions. Conclusion: We surmise that the infrared spectroscopic technique is an ideal tool for the assessment of the drug immobilization and the changes occurring in the course of the modification process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functionalization of Graphene: Covalent and Non-Covalent Approaches, Derivatives and Applications
Georgakilas, V., Otyepka, M., Bourlinos, A. B., Chandra, V., Kim, N., Kemp, K. C., Hobza, P., Zboril, R., & Kim, K. S. (2012) · Chemical Reviews · doi:10.1021/cr3000412 · Cited by 4,109 · cited 1×
“Vibrational spectroscopy, like FTIR and Raman spectroscopy, plays an important role in assessing the covalent and non-covalent functionalization of biomaterials obtained through the incorporation of various functionalities at the material matrix or surface, including immobilization of active compounds [44,45].”
BackgroundBacterial biofilm formation on implantable devices and approaches to its treatment and prevention
Khatoon, Z., McTiernan, C. D., Suuronen, E. J., Mah, T.-F., & Alarcon, E. I. (2018) · Heliyon · doi:10.1016/j.heliyon.2018.e01067 · Cited by 1,187 · cited 2×
“It can be used especially for the eradication of biofilms from the surfac of catheters, prostheses, drains [53], and for the tr atment of the localized infections [54].”
BackgroundPhotodynamic therapy for infections: Clinical applications
Kharkwal, G. B., Sharma, S. K., Huang, Y.-Y., Dai, T., & Hamblin, M. R. (2011) · Lasers in Surgery and Medicine · doi:10.1002/lsm.21080 · Cited by 571 · cited 2×
“Thus, photodyna ic antimicrobial chemother py (PACT) may be an altern tive t the conventional antibiotic therapy [50,52].”
BackgroundAdvances in Mid-Infrared Spectroscopy for Chemical Analysis
Haas, J., & Mizaikoff, B. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041507 · Cited by 385 · cited 2×
“Advance techniques of FTIR are as follows: Fourier transform infrared-attenuated total reflectance (FTIR-ATR), Fourier transform infrared-photo acoustic spectroscopy (FTIR-PAS), Fourier transform infrared imaging spectroscopy (FTIR spectrometer combined with an optical microscope, FTIR-Microscopy), Fourier transform i…”
BackgroundMethodPharmaceutical applications of Mid-IR and Raman spectroscopy
Wartewig, S., & Neubert, R. H. H. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.022 · Cited by 316 · cited 1×
“From the viewpoint of pharmaceutical sciences, the study of substance content in formulations, the study of substance release from formulations, and other kinetic processes, including substance penetration or distribution, are important applications of mid infrared spectroscopy [13,14].”
BackgroundAsefnejad, A., Khorasani, Behnamghader, & Bonakdar (2011) · International Journal of Nanomedicine · doi:10.2147/ijn.s15586 · Cited by 226 · cited 3×
“Besides, the available publications [59,60] report that the band at 1702 cm−1 is assigned to the hydrogen-bonded C=O (hydrogen bonding between C=O and N-H) of urethane linkage, while the peak at about 1720 cm−1 is related to free C=O group.”
BackgroundFTIR Microspectroscopy of Polymeric Systems
Bhargava, R., Wang, S.-Q., & Koenig, J. L. (2003) · Advances in polymer science · doi:10.1007/b11052 · Cited by 197 · cited 1×
“FTIR spectroscopy is a pivotal technique for characterization of polymeric and biopolymeric materials [17,18].”
Amenabar, I., Poly, S., Goikoetxea, M., Nuansing, W., Lasch, P., & Hillenbrand, R. (2017) · Nature Communications · doi:10.1038/ncomms14402 · Cited by 180 · cited 2×
“Advance techniques of FTIR are as follows: Fourier transform infrared-attenuated total reflectance (FTIR-ATR), Fourier transform infrared-photo acoustic spectroscopy (FTIR-PAS), Fourier transform infrared imaging spectroscopy (FTIR spectrometer combined with an optical microscope, FTIR-Microscopy), Fourier transform i…”
BackgroundMethodPrati, S., Joseph, E., Sciutto, G., & Mazzeo, R. (2010) · Accounts of Chemical Research · doi:10.1021/ar900274f · Cited by 177 · cited 2×
“FTIR spectroscopy has also been helpful in performing more advanced analyses aimed at the characterization of artistic materials [14] and disease diagnosis [15,16].”
BackgroundMethodTGA/FTIR: an extremely useful technique for studying polymer degradation
Wilkie, C. A. (1999) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(99)00054-3 · Cited by 166 · cited 1×
“combined with FTIR [22,23] and mass spectrometry; microanalysis of materials to identify contaminants; monitoring of emissions; and failure analysis [24–26].”
BackgroundBi, X., Yang, X., Bostrom, M. P., & Pleshko, N. L. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.05.014 · Cited by 165 · cited 1×
“FTIR spectroscopy has also been helpful in performing more advanced analyses aimed at the characterization of artistic materials [14] and disease diagnosis [15,16].”
MethodDifferential diagnosis of Alzheimer’s disease using spectrochemical analysis of blood
Paraskevaidi, M., Morais, C. L. M., Lima, K. M. G., Snowden, J. S., Saxon, J. A., Richardson, A. M. T., Jones, M., Mann, D. M. A., Allsop, D., Martin-Hirsch, P. L., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701517114 · Cited by 162
Spiridon, I., Teacă, C.-A., & Bodîrlău, R. (2010) · BioResources · doi:10.15376/biores.6.1.400-413 · Cited by 159
Determination of Noncovalent Docking by Infrared Spectroscopy of Cold Gas-Phase Complexes
Garand, É., Kamrath, M. Z., Jordan, P. A., Wolk, A. B., Leavitt, C. M., McCoy, A. B., Miller, S. J., & Johnson, M. A. (2012) · Science · doi:10.1126/science.1214948 · Cited by 155 · cited 1×
“Vibrational spectroscopy, like FTIR and Raman spectroscopy, plays an important role in assessing the covalent and non-covalent functionalization of biomaterials obtained through the incorporation of various functionalities at the material matrix or surface, including immobilization of active compounds [44,45].”
BackgroundThe role of biofilm infection in urology
Peter Tenke, A., Kovács, B., Jäckel, M., & Nagy, E. (2006) · World Journal of Urology · doi:10.1007/s00345-005-0050-2 · Cited by 150 · cited 1×
“This group of antibiotics was selected with regard to a broad spectrum of antimicrobial activity, good penetration properties, and hence their efficacy against the “young” and “old” biofilm and long-time persistence in the biofilm [62].”
BackgroundAn Overview of the Evolution of Infrared Spectroscopy Applied to Bacterial Typing
Quintelas, C., Ferreira, E. C., Lopes, J. A., & Sousa, C. C. S. (2017) · Biotechnology Journal · doi:10.1002/biot.201700449 · Cited by 126 · cited 1×
“The FTIR spectroscopy combined with chemometric analysis provides very rapid, accurate, and generic approaches to the characterization not only of chemical compounds and biomolecules, but also potential biomarkers and microorganisms, including microbial pathogens [41].”
MethodThe potential of mid infrared spectroscopy (MIRS) for real time bioprocess monitoring
Roychoudhury, P., Harvey, L. M., & McNeil, B. W. J. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.086 · Cited by 107 · cited 1×
“Advance techniques of FTIR are as follows: Fourier transform infrared-attenuated total reflectance (FTIR-ATR), Fourier transform infrared-photo acoustic spectroscopy (FTIR-PAS), Fourier transform infrared imaging spectroscopy (FTIR spectrometer combined with an optical microscope, FTIR-Microscopy), Fourier transform i…”
MethodDuemichen, E., Braun, U., Senz, R., Fabian, G., & Stürm, H. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.05.057 · Cited by 103 · cited 1×
“combined with FTIR [22,23] and mass spectrometry; microanalysis of materials to identify contaminants; monitoring of emissions; and failure analysis [24–26].”
Asadinezhad, A., Novák, I., Lehocký, M., Sedlařík, V., Vesel, A., Junkar, I., Sáha, P., & Chodák, I. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900132 · Cited by 80
Rodrigues, G. B., Dias‐Baruffi, M., Holman, N., Wainwright, M., & Braga, G. Ú. L. (2012) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2012.11.004 · Cited by 77
Nabers, A., Ollesch, J., Schartner, J., Kötting, C., Genius, J., Haußmann, U., Klafki, H., Wiltfang, J., & Gerwert, K. B. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400145 · Cited by 73 · cited 2×
“FTIR spectroscopy has also been helpful in performing more advanced analyses aimed at the characterization of artistic materials [14] and disease diagnosis [15,16].”
BackgroundMethodMohammadi, A., Barikani, M., & Barmar, M. (2014) · Polymer Bulletin · doi:10.1007/s00289-014-1268-1 · Cited by 71
Xu, Z., Gao, Y., Meng, S., Yang, B., Pang, L., Wang, C., & Liu, T. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.00242 · Cited by 67
Navarra, G., Cannas, M., D’Amico, M., Giacomazza, D., Militello, V., Vaccaro, L., & Leone, M. (2010) · Food Chemistry · doi:10.1016/j.foodchem.2010.12.010 · Cited by 60
Homogeneous isocyanate- and catalyst-free synthesis of polyurethanes in aqueous media
Sardón, H., Engler, A. C., Chan, J. M. W., Coady, D. J., O’Brien, J. M., Mecerreyes, D., Yang, Y. Y., & Hedrick, J. L. (2013) · Green Chemistry · doi:10.1039/c3gc40319j · Cited by 58 · cited 1×
“The FTIR technology has proved to be useful in identification and characterization of homopolymers, copolymers, or polymer composite, and it has been successfully applied in the evaluation of polymerization process, characterization of the polymer structure, polymer surface, polymer degradation, and polymer modificati…”
MethodVillar, A., Gorritxategi, E., Aranzabe, E., Fernández, S., Otaduy, D., & Fernández, L. A. (2012) · Food Chemistry · doi:10.1016/j.foodchem.2012.07.074 · Cited by 54
Surface Modification of Polyurethanes with Covalent Immobilization of Heparin
Aksoy, E. A., Hasırcı, V., & Hasırcı, N. (2008) · Macromolecular Symposia · doi:10.1002/masy.200850918 · Cited by 46 · cited 1×
“Registration of the material sample spectra after each subsequent stage of modification enabled identification of even the smallest changes without the infrared spectra library searching [31,32,35].”
BackgroundEffects of flax lignin addition on enzymatic oxidation of poly(ethylene adipate) urethanes
Ignat, M.-E., Ignat, M.-E., Ciobanu, C., Doroftei, F., & Popa, V. (2011) · Industrial Crops and Products · doi:10.1016/j.indcrop.2011.03.010 · Cited by 34
Scholz, T., Lopes, V. V., & Calado, C. R. C. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24502 · Cited by 29
Morhardt, C., Ketterer, B., Heißler, S., & Franzreb, M. (2014) · Journal of Molecular Catalysis B Enzymatic · doi:10.1016/j.molcatb.2014.05.018 · Cited by 29 · cited 1×
“As a result of using a standard calibration curve of known concentrations, such measurements become quantitative [39,40].”
BackgroundMicrowave-assisted functionalization of polyurethane surface for improving blood compatibility
You, D., Liang, H., Mai, W., Zeng, R., Tu, M., Zhao, J., & Zha, Z. (2013) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2013.01.027 · Cited by 23
Liu, C., Hu, M., Ma, D., Lei, J., & Xu, J. (2015) · Lasers in Medical Science · doi:10.1007/s10103-015-1859-6 · Cited by 21 · cited 4×
“Thus, photodyna ic antimicrobial chemother py (PACT) may be an altern tive t the conventional antibiotic therapy [50,52].”
BackgroundInfluentialZhou, X., Zhang, T., Jiang, X., & Gu, N. (2009) · Journal of Applied Polymer Science · doi:10.1002/app.31499 · Cited by 19
Zárante, P. H. B., & Sodré, J. R. (2018) · Heat and Mass Transfer · doi:10.1007/s00231-018-2295-5 · Cited by 17
Mart iacute nez-Carpio, P. A., Alcolea-L oacute pez, J. M., & lez, M. V. E. (2012) · LASER THERAPY · doi:10.5978/islsm.12-or-11 · Cited by 7
Cited by
Sikhosana, S. T., Gumede, T. P., Malebo, N. J., Ogundeji, A. O., & Motloung, B. (2023) · Polymer Engineering & Science · doi:10.1002/pen.26293 · Cited by 13
Metadata
- Authors
- Kowalczuk, D., & Pitucha, M.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2019-09-13
- Volume
- 12
- Issue
- 18
- Pages
- 2972
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2972633871
- Cited by
- 178
- References
- 35
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.