Recent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In recent decades, chemiresistive gas sensors (CGS) have been widely studied due to their unique advantages of expedient miniaturization, simple fabrication, easy operation, and low cost. As one ubiquitous interference factor, humidity dramatically affects the performance of CGS, which has been neglected for a long time. With the rapid development of technologies based on gas sensors, including the internet of things (IoT), healthcare, environment monitoring, and food quality assessing, the humidity interference on gas sensors has been attracting increasing attention. Inspiringly, various anti-humidity strategies have been proposed to alleviate the humidity interference in this field; however, comprehensive summaries of these strategies are rarely reported. Therefore, this review aims to summarize the latest research advances on humidity-independent CGS. First, we discussed the humidity interference mechanism on gas sensors. Then, the anti-humidity strategies mainly including surface engineering, physical isolation, working parameters modulation, humidity compensation, and developing novel gas-sensing materials were successively introduced in detail. Finally, challenges and perspectives of improving the humidity tolerance of gas sensors were proposed for future research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Room-temperature gas sensing of ZnO-based gas sensor: A review
Zhu, L., & Zeng, W. (2017) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2017.10.021 · Cited by 1,105
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Machine Learning in Nanoscience: Big Data at Small Scales
Brown, K. A., Brittman, S., Maccaferri, N., Jariwala, D., & Celano, U. (2020) · Nano Letters · doi:10.1021/acs.nanolett.9b04090 · Cited by 229
Wu, J., Wu, Z., Ding, H., Wei, Y., Huang, W., Yang, X., Li, Z., Qiu, L., & Wang, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b18098 · Cited by 104 · cited 1×
“[46] performed the regulation of operating temperature on NO2 sensor based on SnO2-graphene hydrogel to improve its humidity tolerance (Figure 9a).”
MethodFully integrated and portable semiconductor-type multi-gas sensing module for IoT applications
Suh, J.-H., Cho, I., Kang, K., Kweon, S.-J., Lee, M., Yoo, H.-J., & Park, I. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.099 · Cited by 76
Metadata
- Authors
- Wang, Y., & Zhou, Y.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2022-12-07
- Volume
- 15
- Issue
- 24
- Pages
- 8728
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W4311729061
- Cited by
- 180
- References
- 5
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors. https://app.cochat.ai/papers/10.3390/ma15248728
- The paper
- Wang, Y., & Zhou, Y. (2022). Recent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors. Materials. https://doi.org/10.3390/ma15248728
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.