Chloride Corrosion Process of Concrete with Different Water–Binder Ratios under Variable Temperature Drying–Wetting Cycles
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, four water–binder ratios (w/b) of 0.29, 0.33, 0.39, and 0.46 were designed. A variable test temperature was implemented in the drying–wetting cycle test according to the temperature fluctuations in the actual service environment, and the constant temperature test was established as the control group. The mechanical properties and chloride corrosion resistance of concrete with different w/b ratios under variable temperature drying–wetting cycles, as well as the microstructure changes, phase composition, and damage mechanism inside the concrete, were investigated. The results showed that the mechanical properties of concrete increased first and then decreased with drying–wetting cycles increasing, whereas the chloride corrosion resistance continued to decline. A higher w/b exacerbated the deterioration of the concrete performance. A higher w/b increased the porosity, chloride diffusion depth, and chloride content, thus reducing the resistance of chloride corrosion. Compared with w/b = 0.29, the compressive strength, splitting tensile strength, mass, and relative dynamic elasticity modulus of w/b = 0.46 exposed to 60 drying–wetting cycles decreased by 54.50%, 52.44%, 0.96%, and 6.50%, respectively, while the porosity, peak chloride content, and erosion depth increased by 45.12%, 70.45%, and 45.00%. Compared with the drying–wetting cycle with a constant temperature, the cumulative damage caused by the drying–wetting cycle with a variable temperature was greater, resulting in more severe deterioration of concrete performance. The increase in the test temperature significantly accelerated the diffusion rate, penetration depth, and chemical binding capacity of chloride ions. After 60 drying–wetting cycles, the peak chlorine content and erosion depth of w/b = 0.46 under variable temperature cycles were 15.38% and 10.32% higher than those under a constant temperature, while the compressive strength, splitting tensile strength, mass, and relative dynamic elastic modulus were reduced by 7.76%, 14.81%, 0.33%, and 2.40%, respectively. Microscopic analysis confirmed that higher w/b and variable temperature cycles accelerated the decay of mechanical properties and the decline of chloride corrosion resistance. According to the numerical fitting analysis, the w/b should be 0.29~0.39 under the condition that the mechanical properties and chloride corrosion resistance of concrete are met.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“High-strength concretes displayed more stable mass evolution in both environments [31].”
From Mechanisms of Durability Degradation in Recycled Fine Aggregate Concrete of Varying Strengths Induced by Chloride and Sulfate Dry–Wet Cycles (2025) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of supplementary cementitious materials on chloride binding in hardened cement paste
Thomas, M. D. A., Hooton, R. D., Scott, A., & Zibara, H. (2012) · Cement and Concrete Research · doi:10.1016/j.cemconres.2011.01.001 · Cited by 636 · cited 1×
“A similar trend was also obtained in reference [20].”
Result
Research works printed but not linked: 45
- Hu, 2018, The vertical Non-uniform corrosion of Reinforced concrete exposed to the marine environments, Constr. Build. Mater., 183, 180, 10.1016/j.conbuildmat.2018.06.015 · DOI
- Spiesz, 2013, The apparent and effective chloride migration coefficients obtained in migration tests, Cem. Concr. Res., 48, 116, 10.1016/j.cemconres.2013.02.005 · doi:10.1016/j.cemconres.2013.02.005
- Ting, 2021, Cyclic compressive behavior of limestone and silicomanganese slag concrete subjected to sulphate attack and wetting-drying action in marine environment, J. Build. Eng., 44, 103357, 10.1016/j.jobe.2021.103357 · DOI
- Medeiros, 2013, Reinforced concrete in marine environment: Effect of wetting and drying cycles, height and positioning in relation to the sea shore, Constr. Build. Mater., 44, 452, 10.1016/j.conbuildmat.2013.02.078 · DOI
- Shi, 2012, Durability of steel reinforced concrete in chloride environments: An overview, Constr. Build. Mater., 30, 125, 10.1016/j.conbuildmat.2011.12.038 · DOI · Paper page
- Zhong, C., Lu, W., and Mao, W. (2024). Research on Capillary Water Absorption Characteristics of Modified Recycled Concrete under Different Freeze–Thaw Environments. Appl. Sci., 14. · DOI
- Golewski, G.L. (2023). The effect of the addition of coal fly ash (CFA) on the control of water movement within the structure of the concrete. Materials, 16. · doi:10.3390/ma16155218
- Chen, 2023, Chloride penetration of concrete exposed to dry-wet cycle with various dry-wet ratios and temperature, Constr. Build. Mater., 400, 132883, 10.1016/j.conbuildmat.2023.132883 · DOI · Paper page
- Chen, C., Wang, L., Liu, R., Yu, J., and Liu, H. (2023). Chloride penetration of recycled fine aggregate concrete under drying–wetting cycles. Materials, 16. · DOI
- Nematollahzade, 2020, Influence of different curing conditions and water to cement ratio on properties of self-compacting concretes, Constr. Build. Mater., 237, 117570, 10.1016/j.conbuildmat.2019.117570 · doi:10.1016/j.conbuildmat.2019.117570
- Ye, 2016, Chloride ingress profiles and binding capacity of mortar in cyclic drying-wetting salt fog environments, Constr. Build. Mater., 127, 733, 10.1016/j.conbuildmat.2016.10.059 · DOI
- Sun, 2020, Chloride diffusion behavior of engineered cementitious composite under dry-wet cycles, Constr. Build. Mater., 260, 119943, 10.1016/j.conbuildmat.2020.119943 · doi:10.1016/j.conbuildmat.2020.119943
- Wang, 2019, Study on the transport properties of chloride ions in concrete under dry-wet-temperature double cycling, China Concr. Cem. Prod., 2, 6
- Zhou, 2023, Effects of discontinuous dry-wet cycles on the migration of chloride ions in concrete cover, J. Build. Mater., 26, 137
- Liu, 2011, Research on Influecning Factors of Chloride Ion Binding Capability of Concrete, Bull. Chin. Ceram. Soc., 30, 172
- Zibara, 2008, Influence of the C/S and C/A ratios of hydration products on the chloride ion binding capacity of lime-SF and lime-MK mixtures, Cem. Concr. Res., 38, 422, 10.1016/j.cemconres.2007.08.024 · DOI · Paper page
- Yu, 2019, Effect of electrochemical chloride removal and ground granulated blast furnace slag on the chloride binding of cement paste subjected to NaCl and Na2SO4 attack, Constr. Build. Mater., 220, 538, 10.1016/j.conbuildmat.2019.06.033 · DOI
- Song, 2016, Distance-associated chloride binding capacity of cement paste subjected to natural diffusion, Constr. Build. Mater., 112, 925, 10.1016/j.conbuildmat.2016.03.020 · doi:10.1016/j.conbuildmat.2016.03.020
- Chang, 2017, Chloride binding capacity of pastes influenced by carbonation under three conditions, Cem. Concr. Compos., 84, 1, 10.1016/j.cemconcomp.2017.08.011 · DOI · Paper page
- Boddy, 1999, An overview and sensitivity study of a multimechanistic chloride transport model, Cem. Concr. Res., 29, 827, 10.1016/S0008-8846(99)00045-9 · DOI
- Nguyen, 2009, Effect of the environment temperature on the chloride diffusion through CEM-I and CEM-V mortars: An experimental study, Constr. Build. Mater., 23, 795, 10.1016/j.conbuildmat.2008.03.004 · doi:10.1016/j.conbuildmat.2008.03.004
- Dousti, 2013, Influence of exposure temperature on chloride diffusion in concretes incorporating silica fume or natural zeolite, Constr. Build. Mater., 49, 393, 10.1016/j.conbuildmat.2013.08.086 · DOI
- AlKhaja, 1997, Influence of temperature, cement type and level of concrete consolidation on chloride ingress in conventional and high-strength concretes, Constr. Build. Mater., 11, 9, 10.1016/S0950-0618(97)00004-4 · doi:10.1016/s0950-0618(97)00004-4
- Oh, 2007, Effects of material and environmental parameters on chloride penetration profiles in concrete structures, Cem. Concr. Res., 37, 47, 10.1016/j.cemconres.2006.09.005 · DOI
- Song, 2008, Factors influencing chloride transport in concrete structures exposed to marine environments, Cem. Concr. Compos., 30, 113, 10.1016/j.cemconcomp.2007.09.005 · DOI
- Matsumura, 2008, Verification method for durability of reinforced concrete structures subjected to salt attack under high temperature conditions, Nucl. Eng. Des., 238, 1181, 10.1016/j.nucengdes.2007.03.032 · doi:10.1016/j.nucengdes.2007.03.032
- So, 2014, The Properties of Chloride Ion Diffusion of Concrete Under High Temperature Conditions, with Implications for the Storage of Spent Nuclear Fuel in Concrete Casks, Ksce J. Civ. Eng., 18, 2227, 10.1007/s12205-014-0032-2 · doi:10.1007/s12205-014-0032-2
- Chen, 2000, New mix design method for HPC–overall calculation method, Chin. Ceram. Soc., 28, 194
- Tam, 2007, Optimization on proportion for recycled aggregate in concrete using two-stage mixing approach, Constr. Build. Mater., 21, 1928, 10.1016/j.conbuildmat.2006.05.040 · DOI · Paper page
- Zhang, 2021, Island ecosystem evaluation and sustainable development strategies: A case study of the Zhoushan Archipelago, Glob. Ecol. Conserv., 28, e01603
- Amey, 1998, Predicting the service life of concrete marine structures: An environmental methodology, ACI Struct. J., 95, 205
- Wu, 2018, Chloride diffusivity and service life prediction of RC columns with sustained load under chloride environment, Constr. Build. Mater., 158, 97, 10.1016/j.conbuildmat.2017.10.018 · doi:10.1016/j.conbuildmat.2017.10.018
- Zhang, 2017, Experimental research on drying control condition with minimal effect on concrete strength, Constr. Build. Mater., 135, 194, 10.1016/j.conbuildmat.2016.12.141 · doi:10.1016/j.conbuildmat.2016.12.141
- Wang, 2020, Influence of dry-wet ratio on properties and microstructure of concrete under sulfate attack, Constr. Build. Mater., 263, 120635, 10.1016/j.conbuildmat.2020.120635 · DOI · Paper page
- Glasser, 1998, Friedel’s salt, Ca2Al(OH)6(Cl,OH)·2H2O: Its solid solutions and their role in chloride binding, Cem. Concr. Res., 28, 1713, 10.1016/S0008-8846(98)00162-8 · DOI · Paper page
- Du, 2020, Effect of Different Humidity-Controlling Modes on Microstructure and Compressive Behavior of Ordinary Concrete, J. Mater. Civ. Eng., 32, 04019337, 10.1061/(ASCE)MT.1943-5533.0003005 · doi:10.1061/(asce)mt.1943-5533.0003005
- Ma, 2023, A review on the deterioration of mechanical and durability performance of marine-concrete under the scouring action, J. Build. Eng., 66, 105924, 10.1016/j.jobe.2023.105924 · DOI
- Ma, 2018, Durability of concrete subjected to dry-wet cycles in various types of salt lake brines, Constr. Build. Mater., 193, 286, 10.1016/j.conbuildmat.2018.10.211 · DOI
- Cordeiro, 2015, Use of thermal analysis to determine the hydration products of oil well cement pastes containing NaCl and KCl, J. Therm. Anal. Calorim., 122, 1279, 10.1007/s10973-015-4949-6 · doi:10.1007/s10973-015-4949-6
- Silva, 2021, Durability of self-compacting concrete with addition of residue of masonry when exposed to carbonation and chlorides mediums, Constr. Build. Mater., 297, 123817, 10.1016/j.conbuildmat.2021.123817 · DOI
- Cheewaket, 2014, Concrete durability presented by acceptable chloride level and chloride diffusion coefficient in concrete: 10-year results in marine site, Mater. Struct., 47, 1501, 10.1617/s11527-013-0131-4 · DOI
- Cao, 2022, Influence of the dry/wet ratio on the chloride convection zone of concrete in a marine environment, Constr. Build. Mater., 316, 125794, 10.1016/j.conbuildmat.2021.125794 · DOI
- Bao, 2022, Numerical and experimental investigation of coupled capillary suction and chloride penetration in unsaturated concrete under cyclic drying-wetting condition, J. Build. Eng., 51, 104273, 10.1016/j.jobe.2022.104273 · doi:10.1016/j.jobe.2022.104273
- Wang, 2018, Effects of coarse aggregates on chloride diffusion coefficients of concrete and interfacial transition zone under experimental drying-wetting cycles, Constr. Build. Mater., 185, 230, 10.1016/j.conbuildmat.2018.07.049 · DOI
- Ye, 2012, Model of chloride penetration into cracked concrete subject to drying-wetting cycles, Constr. Build. Mater., 36, 259, 10.1016/j.conbuildmat.2012.05.027 · DOI · Paper page
Cited by
Chen, C., Alimatu Adama, K., Liu, R., Chen, Y., Zhang, X., & Liu, H. (2025) · Materials · doi:10.3390/ma18214985 · Cited by 8
Self-citation
Metadata
- Authors
- Wang, L., Chen, C., Liu, R., Zhu, P., Liu, H., Jiang, H., & Yu, J.
- Affiliations
- School of Urban Construction, Changzhou University, Changzhou 213164, China
- Faculty of Civil Engineering and Mechanics, Jiangsu University, Zhenjiang 212013, China
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2024-05-11
- Volume
- 17
- Issue
- 10
- Pages
- 2263
- ISSN
- 1996-1944
- Cited by
- 11
- References
- 1
- Language
- en
- Funders
- National Natural Science Foundation of China (52108190, 51778272, 51278073)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.